Good Quality Portable Vital Sign Monitor Bvm-8

China Good Quality Portable Vital Sign Monitor Bvm-8, Find details about China Cardiac Monitor, Pulse Oximeter from Good Quality Portable Vital Sign Monitor Bvm-8

Model NO.
BVM-8
Parameter
SpO2, Pulse Rate, NIBP
Battery
Build in Rechargeable up to 15 Hours Running
Application
Adult, Pediatric, Infant, Neonate
Optional
Nellcor SpO2/ Masimo Sp02
Alarm
Low, Medium and High
Warranty
18 Month
Trademark
BENEMED
Transport Package
Carton with Foam
Specification
210*170*75mm
Origin
China
HS Code
9018199000
Model NO.
BVM-8
Parameter
SpO2, Pulse Rate, NIBP
Battery
Build in Rechargeable up to 15 Hours Running
Application
Adult, Pediatric, Infant, Neonate
Optional
Nellcor SpO2/ Masimo Sp02
Alarm
Low, Medium and High
Warranty
18 Month
Trademark
BENEMED
Transport Package
Carton with Foam
Specification
210*170*75mm
Origin
China
HS Code
9018199000
BENEMED Good quality Portable Vital Sign Monitor BVM-8 with SPO2, RESP, NIBP 
Good Quality Portable Vital Sign Monitor Bvm-8

1. Dimension and Weight
-- Dimension: 210mm×170mm×75mm
-- Net Weight: 1 kg
Display Specification
-- LED + LCD
-- LCD Size: 85mm * 30mm

2.Power Supply
AC Power Adaptor
-- Voltage: AC100 ~ 240V, 50/60Hz
-- Adapter: Output 5VDC, 4A
Battery
-- Type: Rechargeable Lithium battery 3.7V/2200mAh
-- Charge Cycl: ≥500 times
-- Working time: 3 hours
-- Optional large battery for 8-9 hours work

3. Environment
Temperature
-- Working: 5 ~ 40 °C
-- Transport and Storage: -20 ~ 50°C
Humidity
-- Working: 15 ~ 80 % (non-condensing)
-- Transport and Storage: 10 ~ 90 % (non-condensing)
Atmosphere pressure
-- Working: 86 KPa ~ 110 KPa
-- Transport and Storage: 86 KPa ~ 110 KPa

 
4.Monitoring Parameter
NIBP
-- Method: Oscillometric
-- Mode: Manual, Auto, STAT
-- Measuring Interval in AUTO Mode: 1 ~ 480 min
-- STAT mode cycle time: Keep 5 minutes, at 5 seconds interval
-- Measure and Alarm Range:
Adult: SYS: 30 ~ 270 mmHg
DIA: 10 ~ 220 mmHg
MEAN: 20 ~ 235 mmHg
Pediatric: SYS: 40 ~ 235 mmHg
DIA: 10 ~ 220 mmHg
MEAN: 20 ~ 225 mmHg
Neonate: SYS: 30 ~ 135 mmHg
DIA: 10 ~ 110 mmHg
MEAN: 20 ~ 125 mmHg
-- Static pressure accuracy: ±3mmHg
-- Resolution: 1mmHg
-- Accuracy: Maximum Mean error ±5mmHg
Maximum Standard deviation 8mmHg
-- Over pressure Protection: Dual protection via software & hardware
SpO2
SpO2
-- Measuring Range: 0 ~ 100%
-- Resolution: 1 %
-- Support Pitch tone and multi-level volume
-- Accuracy: ±2% (80 ~ 100%), ±3% (70 ~ 80%), unspecified (0~ 69%)
-- PI range: 0.075% ~ 20%
Pulse Rate
-- Measuring and Alarm Range: 25 ~250bpm
-- Resolution: 1bpm
-- Accuracy: ±1bpm or ±1 bpm, whichever is greater
 
5.Trend and Review
-- Trend: 100 hours of patient SpO2
-- NIBP measurement reviewing: 500groups

6.Alarm
-- Level: Low, mesium, high
-- Indication: Auditory and visual
-- Alarm volume adjustable
 
7.System Output
-- Ethernet Network: standard RJ45 socket*1
-- USB Port*1