Humidity Sensor Hr002 for Air Control System

China Humidity Sensor Hr002 for Air Control System, Find details about China Moisture Sensor from Humidity Sensor Hr002 for Air Control System

Model NO.
HR002
Measuring Medium
Humidity
IP Rating
IP20
Certification
CE
Customized
Customized
Trademark
HW
Transport Package
1000PCS in One Pack
Specification
100000pcs in one carton
Origin
Guangdong, China
HS Code
8421991000
Model NO.
HR002
Measuring Medium
Humidity
IP Rating
IP20
Certification
CE
Customized
Customized
Trademark
HW
Transport Package
1000PCS in One Pack
Specification
100000pcs in one carton
Origin
Guangdong, China
HS Code
8421991000

1. Product introduction:

The product is called resistance type polymer humidity sensor (HR002) and it is a new type of humidity sensor. It has the characteristics of wide sensing range, fast response, high sensitivity, good water resistance, stable and reliable performance, and good consistency.


2.Electrical performance:
1. Rated voltage: 1.5V AC (MAX, sine wave);
2. Rated power: 0.2mW (MAX, sine wave);
3. operating frequency: 50Hz-2000Hz;
4. working temperature: 0 °C -60 °C;
5. working humidity: 20% - 95% RH;
6. Temperature characteristics: ≤0.5%RH/°C
7. hysteresis hysteresis: ≤ 2% RH;
8. Response time: moisture absorption, ≤15S; dehumidification ≤25S;
9. Stability: ≤ 2% RH/year;
10. Humidity detection accuracy: ≤±5%RH;
11. Relative humidity impedance characteristics: (25°C, 1KHZ, AC1V, sine wave)

 

3.Standard verification conditions:

1.In the atmosphere, the temperature is 25°C, the measured frequency is 1KHZ, and the measured voltage is IVAC (sine wave);
2.Make sure to use AC bridge (LCR) when testing, and do not use DC power supply;
3.Use split-type humidity generator (HX-1 type);
4.Measurement line: 1-core shielded wire.
5.Avoid hard objects or fingers touching the surface of components to avoid scratching or staining the wet film;
6.Avoid testing under salt spray, corrosive gases, strong acids, strong bases, organic solvents, alcohol, acetone, etc.
7.Welding conditions (180°C, 3S) For welding, use a low-temperature soldering iron or use tweezers for protection.
8.Recommended Storage Conditions: Temperature 10°C-40°C, Humidity: 20%RH-90%RH.


The specification value is based on the 60%RH humidity change amount; after each test is completed, it should be placed in the normal air of normal temperature and humidity for 24 hours and tested after recovery. The test data are listed in the table.   
Humidity Sensor Hr002 for Air Control System

1-Exported feet  2-Substrates  3-Carbon Electrodes  4-Sensitive Wet Film
Figure 1 (1008) dimensions



Table 1 Humidity Impedance Characteristics Table at 0°C to 60°C (31KΩ)
  0ºC 5ºC10ºC 15ºC 20ºC 25ºC 30ºC 35ºC 40ºC 45ºC 50ºC 55ºC 60ºC 
20%RH   2290175913511027780591448359288227
25%RH 210016201250935700539415328260218183149
30%RH1543117587465049838230223819816514312494
35%RH83261246535327721718015012810990.47561.8
40%RH4433352602021651351149781.26859.55243.6
45%RH2481901531231059076.56555.647.541.93731.3
50%RH14611598.985726152.44539.13430.126.722.7
55%RH948068.15849.94337.1322824.521.919.515.6
60%RH64.35648.241.535.93126.622.920.217.81512.610
65%RH45.94135.13025.922.319.216.513.811.69.67.96.45
70%RH33.43025.621.918.715.913.110.897.56.25.134.29
75%RH24.421.518.315.612.810.58.697.25.954.924.133.462.84
80%RH17.415.312.610.38.57.035.84.783.983.312.732.251.88
85%RH1210.28.46.915.674.653.863.22.652.191.811.491.24
90%RH7.96.875.64.563.773.112.562.111.741.441.190.990.82

Figure 2 humidity impedance characteristics (31KΩ)
Table 2 0°C to 60°C (23KΩ) Humidity Impedance Characteristics Data Sheet
  0ºC 5ºC10ºC 15ºC 20ºC 25ºC 30ºC 35ºC 40ºC 45ºC 50ºC 55ºC 60ºC 
20%RH   1699.0 1305.1 1002.4 762.0 578.7 438.5 332.4 266.4 213.7 168.4 
25%RH 1558.1 1201.9 927.4 693.7 519.4 399.9 307.9 243.4 192.9 161.7 135.8 110.5 
30%RH1144.8 871.8 648.5 482.3 369.5 283.4 224.1 176.6 146.9 122.4 106.1 92.0 69.7 
35%RH617.3 454.1 345.0 261.9 205.5 161.0 133.5 111.3 95.0 80.9 67.1 55.6 45.9 
40%RH328.7 248.5 192.9 149.9 122.4 100.2 84.6 72.0 60.2 50.5 44.1 38.6 32.3 
45%RH184.0 141.0 113.5 91.3 77.9 66.8 56.8 48.2 41.3 35.2 31.1 27.5 23.2 
50%RH108.3 85.3 73.4 63.1 53.4 45.3 38.9 33.4 29.0 25.2 22.3 19.8 16.8 
55%RH69.7 59.4 50.5 43.0 37.0 31.9 27.5 23.7 20.8 18.2 16.2 14.5 11.6 
60%RH47.7 41.5 35.8 30.8 26.6 23.0 19.7 17.0 15.0 13.2 11.1 9.3 7.4 
65%RH34.1 30.4 26.0 22.3 19.2 16.5 14.2 12.2 10.2 8.6 7.1 5.9 4.8 
70%RH24.8 22.3 19.0 16.2 13.9 11.8 9.7 8.0 6.7 5.6 4.6 3.8 3.2 
75%RH18.1 16.0 13.6 11.6 9.5 7.8 6.4 5.3 4.4 3.7 3.1 2.6 2.1 
80%RH12.9 11.4 9.3 7.6 6.3 5.2 4.3 3.5 3.0 2.5 2.0 1.7 1.4 
85%RH8.9 7.6 6.2 5.1 4.2 3.5 2.9 2.4 2.0 1.6 1.3 1.1 0.9 
90%RH5.9 5.1 4.2 3.4 2.8 2.3 1.9 1.6 1.3 1.1 0.9 0.7 0.6 


Humidity Sensor Hr002 for Air Control System
Figure 3 Humidity Impedance Characteristic Diagram (23KΩ)
Humidity Sensor Hr002 for Air Control System

Humidity Sensor Hr002 for Air Control System