Old Battery Professional Renovator Battery Regenerator

China Old Battery Professional Renovator Battery Regenerator, Find details about China Battery Restoration Appliance, Battery Restoration Unit from Old Battery Professional Renovator Battery Regenerator

Model NO.
DK-G50
Trademark
DK
Specification
1100*400*1810 mm
Origin
China
HS Code
9030891000
Model NO.
DK-G50
Trademark
DK
Specification
1100*400*1810 mm
Origin
China
HS Code
9030891000
Old Battery Professional Renovator Battery Regenerator

Description:

Storage Battery Comprehensive Regeneration System DK-G50
is specially designed for regenerating early failure batteries, capacity fading batteries and no-current-output batteries(Failure Batteries) and so on which are result from the vulcanization in the plate. The equipment DK-G50 is integrated with Charge, Discharge, Auto-cycling, Pulse Desulphuration, Pulse Activation. Which can effectively restore the sulfated batteries. It's especially suitable for maintenance, restoration of 6V, 12V, 16V,18V lead acid batteries, which has the obvious effect on prolonging the battery service life.

The main issue of battery vulcanization failure:
  1. The voltage rises quickly when charging, and it turns green in 2-3 hours or less.
  2. When fully charged, the voltage is higher than 13.4V after standing for a long time (take 12V battery as an example)
  3. With your ear close to the battery, you can hear the sound of "squeak".
  4. The battery generates heat and the temperature rises quickly.
  5. It's full as soon as it is charged, and it's gone as soon as it runs.

The main causes of battery vulcanization failure:
  1. Regularly insufficient charging.
  2. Not charging in time after discharging.
  3. Unplug the power supply when it turns green during charging, without sufficient floating charge.
  4. Long-term over-discharging.
  5. Self-discharge of the battery causes deep discharge of small current.
  6. New batteries long-term storage without regular charge-discharge maintenance causes battery self-discharge.
  7. Lay aside discharged or half discharged batteries too long.
  8. Electrolyte acidity is not high, purity is not pure.

Application: Lead-acid Batteries 6V/12V/16V/18V
 
Illustration:

Old Battery Professional Renovator Battery Regenerator

 
Basic Function:
  1. Charge
  2. Discharge
  3. Auto-cycle charge and discharge
  4. Water-replenishing maintenance charge
  5. Pulse repair
  6. Constant current overcharge repair
  7. Activation repair

       
Characteristics:
  1. Independent modular design, easy maintenance, and the modules do not affect each other. Even if the individual modules fail, it will not affect the normal use of other modules..
  2. The circuit is connected by the connectors for convenient replacement.
  3. With over-current and over-voltage protection.
  4. Polar protection, anti-reverse connection
  5. Built-in fan to help the heat dissipation and improve the stability
  6. Capacity test: Suitable for 6V,12V ,16V, 18V lead acid battery, It integrates charge, discharge function, discharge current 0.5-10A is adjustable, the charge current 0.5-6A is adjustable, accurately detect the battery capacity(it can be discharged in parallel by multiple channels to increase discharge test current and achieve the purpose of a higher current discharge).
  7. Maintenance:  Adopting the technology of high frequency pulse desulfurization, it has the good no-destructive repair effect on the sulphated batteries. The current is adjustable during operation to accommodate the different specification batteries.
  8. Activation repair: Special strengthening treatment of batteries with pulse large current(Max. peak up to 200A), which has obvious affect on activating badly sulphated batteries(can't be charged and discharged)


Technical Specification
   
Model No.:DK-G50
Total Channel Number:50 Channels
Pulse Repair Channels:24 Channel
Capacity Test Channels:24 Channels
HF Activating Repair Channels:2 Channels
Power Supply:AC 220V±10% 50 Hz
Power:No-load 620 W, Full-loading 7 KW
Power Factor:0.85
Pulse Repair
Waveform: 8330 Hz Square wave
Pulse Edge:≤20ns
Duty Ratio:Adjustable
Max. Output Average Current:≥0.8A
Capacity Test
Max. Discharge Current:20A(0.5-20A) adjustable
Max. Charge Current: 10A (0.5-10A) adjustable
Min. discharge final voltage:Can be adjusted to 2V
Max. charge voltage:Can be adjusted to 23V
HF Activating Repair Channels
Pulse Frequency:15 KHz
Max. Peak Current:200A
Average Value of Output Current:0-20A Constant current adjustable
Max. Average Current:≥10A
 
Packing Information
ModelProduct SizeG.W.
DK-G502160*400*170 mm182 KG
 
Application:


Old Battery Professional Renovator Battery Regenerator

About us:
Founded in 2005, DEKANG is a high-tech enterprise involved in researching & development, production and sales of Storage Battery Detection Equipment, Charging Station, Shared Mobility Solution. We provide the clients with the complete solution of storage batter service.

Products Category:
Battery Testing and Maintenance Machine
Battery Regeneration Equipment
Intelligent Battery Charger

E-Bike/E-scooter Charging Station
Shared Battery Charging & Swapping System
Intelligent Lithium Batteries
Battery-swapping E-bike/E-scooter and so on.


Why choice us?
  1. Beginning from 2005, we have achieved the leadership of our industrial
  2. Over 15 years of experiences
  3. Powerful function and superior performance
  4. Professional and strong R&D team.
  5. Technical leadership and advantage
  6. Advanced production technology and automatic assembly line
  7. Market verification and specialized users approval from over 50 countries
  8. Rich experience in market operation
  9. Professional after-sale service, lifelong after-sale service provided
Delivery
Sample order dispatched by express via DHL, FEDEX,TNT,UPS or any other express services you prefer to, also we can coordinate to send it to other agreed address in China for loading with your convenience

Normal order delivered by sea or air as per your instructions.


Warranty:
12-month warranty, lifelong after-sale service and free technology service.

After-sales service
Free replacement parts will be provided during the warranty period, and we will dispatch the replacement parts to the user by DHL,UPS,TNT or FEDEX at our account and guide the user to replace via phone, email or video.

After the warranty period, the cost of replacement parts will be charged. If you pay for the replacement parts, you can enjoy free warranty within half a year from the maintenance date for the same problem.

Lifelong free technology service provided by us, the users can advise malfunction and inquire the maintenance technology through the telephone, fax, email, and social media, etc.


Paid service
The conditions in the below not included in the free maintenance range, the company provide with the paid service, kindly note:
  1. Do not operate or use as per the manual and cause the damage
  2. The instrument was disassembled or repaired by the non-authorized person by our company
  3. Unexpected factors or man-made causes the damage, such as the water inflowing, mechanical damage, falling, burning and so on.
EXPO
Old Battery Professional Renovator Battery Regenerator


R & D
Old Battery Professional Renovator Battery Regenerator



PRODUCTION
Old Battery Professional Renovator Battery Regenerator


DEKANG IMAGES
Old Battery Professional Renovator Battery Regenerator