Analog Panel Kw Meter ( 6L2 -KW)

China Analog Panel Kw Meter (6L2-KW), Find details about China Panel Meter, Analog Meter from Analog Panel Kw Meter (6L2-KW)

Model NO.
6L2-KW
Model NO.
6L2-KW
Analog Panel kw meter (6L2-KW)


Changes caused by the temperature:

Temperature range for reference: 23° C± 2° C, 13° C~23° C, and 23° C~33° C. The changes caused by the impact of temperature are not allowed to be out of the range of the level index ± 100%.

The installation:

Unless specified, the meter is usually installed in a vertical position. Other installation positions such as horizontal and inclined position can be installed according to the customer's requirements. The corresponding level of accuracy is only valid to the regulated installation position. The meter has two kinds of instruction angles: Right angle 90° And wide angle 250° .

Anti-vibration and anti-shock:

Anti-vibration: Complies with the standard of IEC60068-2-6; Frequency sweep range: 10-55-10Hz; Displacement amplitude: ± 0.15mm, ± 0.3mm; Frequency sweep cycles: 5 times; Sweep rate: 10ct/min; Maximum acceleration: 147m/s2(15g), 490m/s2(50g); RMS acceleration: 6.06g; Vibration time: 15 min. Anti mechanical shock: Complies with the standard of IEC60068-2-27.


Extrinsic current shunt:

The voltage specifications of the extrinsic current shunt of DC ammeters are 150mV, 100mV, 75mV, 60mV and 50mV, which can be customized. The resistance of the conducting wire connecting the meter and the current shunt should within the range of 1525mΩ , to ensure the accuracy of the meter.

The surface of the dial:

The surface of the dial uses aluminum alloy, white paint, black ink printing or laser printing. The dial can be customized according to the customer's sample dials (overprint colors can be customized). The luminous dial uses the PC panel.

Name

precision

normal specification

remark

AC ammeter

A

1.5

0.5-50A

can be directly connected

A

1.5

10/5A-800/5A
secondary current passed by current transformer

KA

1.5

1KA-10KA
secondary current passed by current transformer

AC voltmeter

V

1.5

10V-600V

can be directly connected

KV

1.5

1KV-35KV

100V secondary voltage passed by voltage transformer

DC ammeter

µA mA

2.5

50μA-500μA 1mA-500mA
can be directly connected

A

1.5

1A-15A

can be directly connected

A

1.5

15A-750A

 outer attached shunt 75mV 60mV 50mV

KA

1.5

1KA-3KA

outer attached shunt 75mV 60mV 50mV

DC voltmeter

V

1.5

3V-600V

can be directly connected

KV

1.5

1KV-3KV

outer attached resistance value

Hz meter

Hz

2.5

45-55HZ 55-65HZ

36V.100V.127V.220V.380V

Power meter

KW.VAR

2.5

100V 380V 380-380KV

100V secondary voltage passed by voltage ; Secondary current passed by current transformer 5-10KA/5A

cosφ meter

cosφ

2.5

COSφ =0.5-1-0.5

100V/5A 220V/5A 380V/5A

Three-phase synchronous table

S

2.5

100V,220V,380/100V