Expulsion Fuse-Cut out 10kv

China Expulsion Fuse-Cut out 10kv, Find details about China Loadbreak Cutout, Arc Chute Type from Expulsion Fuse-Cut out 10kv

Model NO.
PRW-10KV
Standard
IEC IEEE
Trademark
OEIpower
Transport Package
Cartons Pallets Wooden Case
Specification
IEC IEEE
Origin
China Nanyang
HS Code
85351000
Model NO.
PRW-10KV
Standard
IEC IEEE
Trademark
OEIpower
Transport Package
Cartons Pallets Wooden Case
Specification
IEC IEEE
Origin
China Nanyang
HS Code
85351000


Expulsion Fuse-Cut out 10kv
Expulsion Fuse-Cut out 10kv
Expulsion Fuse-Cut out 10kv
Expulsion Fuse-Cut out 10kv
Expulsion Fuse-Cut out 10kv
Expulsion Fuse-Cut out 10kv
Expulsion Fuse-Cut out 10kv
Expulsion Fuse-Cut out 10kv
Expulsion Fuse-Cut out 10kv
Expulsion Fuse-Cut out 10kv
Expulsion Fuse-Cut out 10kv
TYPE "OEI" "PRW" STANDARD CUTOUT DISTRIBUTION TECHNICAL SPECIFICATION
The Fuse Cutout type DHE was developed to operate in overhead distribution systems rated at 12-15 kV and 15-27,kV or 27-38 kV grounded systems with 100 or 200 A nominal currents.
Especially designed to protect transformers, capacitors, cables or lines.
It is robust construction, made of rigorously tested material, will interrupt all faults under the
most severe conditions, maintaining mechanical and electric characteristics.
The inserts, hardware and structural bolts and nuts are made from heavy galvanized steel.
The Fuse Cutout type OEI PRW can be applied on all three-phase system rated at or below the maximum operational rating of the cutout. In highly polluted environments or environments with high levels of salinity, a cutout may be used with a higher nominal rating than
that of the system where it is being installed, where the insulator will have a greater leakage distance to ground, allowing for
increased safety against discharge. For an even better protection against abrasions, the hardware may be supplied in stainless
steel. The fuse cutout type MZ has attachment hooks in aluminum.
The Fuseholder has a stainless steel flipper, which associated with a spring doesn't allow the fuse link to be subject to traction
forces of over 3 Kgf, especially during closing. This me chanism also allows for high speed fuse link separation. The fuse cutout
type OEI PRW allows for the insertion of the fuse tube in a precise man ner and always in perfect alignment, due to the large distance
between the grunion pocket. Lower contact, silver-to-silver, provide du el current path, independent of hinge pivot. Stainless-steel
back-up springs prevent arcing when tube rises in hinge during recoil. The fuse cutout type OEI PRW may be transformed into a DI
CONNECT up to 300 A, by simply changing the fuse tube for an electrolytic copper blade.
The DHE Fuse Cutouts conform to ANSI and IEC standards, with independent tests performed At:
CPRI Always use quality fuse links. Only they can assure excellent performance.


Fuse assembly with rewirable fuse link:
rating available (type K or T) 1,2,3,5,10,15,20,25,30,
40,50,60,75 * 100A
? A spring loaded flipper and locking mechanism at the
lower end of the fuse carrier ensures consistent
tension on the fuse link and prevents element damage
during 'close in'
? Galvanised steel phase channel bases
? Connector terminals suitable for conductor sizes
ranging from 3mm to 12mm diameter
? Hook Stick operation
 
Performance Characteristic
Applied standardIEEE C37.42-2009
Catalog number 
Nominal system voltage kV33
Rated Frequency Hz50
Rated m aximum(design) voltage38
Rated Continuous current A-RMS100
Rated Interrupting current asymmetrical/symmetrical A-RMS8000/5000
BIL 1.2x50 µs kV-peak150
Minimum critical impulse flashover voltage(CFO)KV peak165
Dry withstand voltage kV-RMS70
Wet withstand voltage kV-RMS60
Creepage distance to group Min.mm650