Patient ICU Monitor for Invasive

China Patient ICU Monitor for Invasive, Find details about China Patient Monitor, ICU Monitor from Patient ICU Monitor for Invasive

Model NO.
SNP9000W
Trademark
JYK
Specification
CE, FDA
Origin
Guangdong, China
Model NO.
SNP9000W
Trademark
JYK
Specification
CE, FDA
Origin
Guangdong, China
Medical equipment, bedside monitor, invasive patient monitor, ICU monitor,  measure artery monitor
medical monitor, hospital monitor , invasive monitor


MONITOR (for measure artery, invasive)
ICU Monitor

Multi-Para Patient monitor
bedside monitor

ICU monitor
15" Standard 6 Parameters
ECG, NIBP,SpO2,RESP, TEMP,HR/PR


Features &Benefits:
  1. 15" color TFT display, high resolution: 1024×768dpi;
  2. Separated para board: ECG, NIBP, SpO2 board;
  3. Full touch-screen enables intuitive operation by clicking one the specific parameters or the waveform in real time, standard configuration includes the navigation knob.
  4. Real time S-T segment analysis, and ARR analysis;
  5. SpO2 Pitch Tone Variation and Drug Dose Calculation;
  6. Parameter waveform and characters color selectable
  7. Multi-display: Standard, Large font, Trend Coexis, OxyCRG dynamic
  8. Standby mode for Energy saving and suspend monitoring;
  9. 7-lead ECG waveforms display in phase;
  10. Capture dynamic waveforms;
  11. Built-in rechargeable lithium battery, and battery volume checking,
  12. AC power checking
  13. Efficient resistance to interference of defibrillator and HF knife;
  14. SINNOR F-6 SpO2 technology, VS NELLCOR accuracy;
  15. Networking capacity and TCP/IP networking platform enable abundant future upgrade
  16. Time delay switch-off function keep the monitor data restart monitor;
  17. Complete and flexible mounting solution for transportation and in-patient monitoring

Standard parameters: 5-lead ECG, SpO2(F-5),NIBP, TEMP,RESP,PR,HR.
Optional: Touch Screen, Thermal Recorder, 3/12-lead ECG, 2/4-IBP,4-TEMP,2-SpO2, Nellcor/Masimo SpO2,BIS, Phaisein/ Respironics Multi-gas, ICG/CO, FHR, FM, TOCO,



Performance Specifications
Display:       15"color TFT
Rolling and refreshing waveform display
Resolution: 1024×768
Multi display selectable including:
Large-font display
Trend coexist display
OxyCRG dynamic view display.
Bed-to-bed view display
Trace:             9 waveforms(7 ECG, 1 SPO2 and 1 RESP)
Sweep speed:12.5mm/s,25mm/s,50mm/s
Indicator:          Power/battery indicator light
QRS beep and alarm sound
Battery:           Rechargeable lead acid cell, 12v/4AH
Max.24 hour for charging, 4 hours for continue working
Trend:             Parameter graphic and tabular trends:
5s/piece,8 hours;
1min/piece,168 hours(24hour×7days)
5min/piece,1000 hours.

Storage:           NIBP: 1000 groups
Alarm: 200 groups
Full disclosure waveforms: 3600S
SD card external storage
Alarm:         User-adjustable High, Medium and Low limits 3-level
 Audible and visual alarm
Networking:        Connected to central monitoring system
TCP/IP netting platform
Recorder:         Build-in, thermal array
Plethysmogram caveform:2 channels
Record mode: manual, on alarm, time-defined
Recording width: 50mm
Printing speed: 50mm/s
Recording type:    Frozen waveform record
NIBP recall record
Trend table record
Alarm record
Fixed -time record


Standard parameter:
ECG:

Lead mode: 5 -lead(R,L,F,N,C)
Lead selection : I,II,III,avR,avL,avF,V
Waveform:     3 and 7 channel selectable
Gain selection: 0.5mm/mv,1mm/mv,2mm/mv
Sweep speed: 12.5mm/s;25mm/s;50mm/s
Heart rate range:    Adult: 15~300bpm;
Neonate/pediatric:15~350bpm
Accuracy: +1bpm or +1%,whichecer is greater
Resolution:     1bpm
Filter: surgery mode:1~20Hz
monitor model:0.5~40Hz
Diagnostic mode:0.05~130Hz
Scaling signal: 1mv,+3%
Protection:       withstand 4000VAC/50 voltage isolation against electrosurgical interference and defibrillation
Alarm range: 15~350bpm
S-T segment detecton:
Measurement range:    2.0mV~+2.0mV                         
 
 Alarm Range:          -2.0mV~ +2.0mV
Accuracy:              -0.8mV ~+0.8Mv
Error:                 +0.02Mv
 
Arrhythmia analysis:    YES

SPO2
Measurement range:        0~100%
Resolution:                1%
Accuracy:                 +2%(70-100%);0-69% unspecified
Alarm range               0~100%
Pluse Rate:                
range:                 20~300bpm
Resolution:             1bpm
Error:                 +1bpm or +2%,whichever is greater

NIBP
Method:                   Digital Automatic oscillometric
Operation mode :            Manual/Automatic/continuous
Auto measurement time:      Adjustable(1~480min)
Measurement Unit:          mmHg/Kpa selectable
Measurement types:         Systolic, Diastolic, Mean  
Measurement tange:
Range of Systolic pressure:    Adult: 40~270mmHg
Pediatric: 40~220mmHg
Neonate: 40~135mmHg
Range of mean pressure:      Adult: 20~235mmHg
Pediatric: 20~165mmHg
Neonate: 20~110mmHg
Range of diastolic pressure:   Adult: 10~215mmHg
Pediatric: 10~150mmHg
Neonate :10~100mmHg
Over-pressure protection:     Double safety protection
Resolution:                 1 mmHg
Alarm:                    Systolic.Diastolic,Mean


RESPIRATION
Method:                     Thoracic impedance
Measurement range:           Adult:7~120rpm;
Neonate/Pediatric:7~150rpm
Apnea alarm:                 YES,10~40s
Resolution:                   1rpm
Accuracy:                    +2rpm


TEMPERATURE
Compatible probe:             YSI or CYF
Measurement range:           5~50ºC
Resolution :                   0.1ºC
Accuracy:                    +0.1ºC
Refreshing time:               about 1
Average measuring time:        <10s

FHR
Transducer:   Multi-crystal, Pulsed Doppler
Measurement range:  50~210 BPM
Working frequency:   1 MHz
Strength:   <5mW/cm2
Signal processing:  
special DSP system and modern recognization.
Resolution:   1BPM
Accuracy:    ±1BPM
Alarm Range:  High: 160,170,180,190 BPM,
Low: 100,110,120 BPM

FM
Manual button marking,
automatic FM identifying function

TOCO Measuring
Transducer:  External pressure transducer
Measurement range:  0~100 units
Resolution:  1rpm
Accuracy:  ±2 rpm


IBP
Channel: 2 channels
Range: -50-300mmHg
Resolution: 1mmHg
Accuracy: ±4mmHg(±4%)
Unit: mmHg, Kpa
Converter Sensitivity: 5mV/V/mmHg
Transducer sites: ART/PA/CVP/LAP/RAP/ICP

EtCO2( Sidertream CO2)
Measurement range:   0~99mmHg
Accuracy:   +2mmHg (0~40mmHg)
Sampling Range:   100ml/min
Sampling rate accuracy:   15%
Respiration rate:   0~120rmp
Respiration accuracy:  +2rmp (0~70rmp)
+5rmp (>70rmp)
Respiration time:   <240msec (10% to 90%)
Delay time:  <2s

EtCO2 (mainstreaam CO2)
Method:   Infrared Spectrum
Range:   0.0-10% (0~76%)
Resolution:   1mmHg (0.1%)
Accuracy:   <5%(±4.0 mmHg)
         Or<10%(of Readings)

Recorder:     
Build-in, thermal array
Plethysmogram caveform:2 channels
Record mode: manual, on alarm, time-defined
Recording width: 50mm
Printing speed: 50mm/s
Recording type:  Frozen waveform record
NIBP recall record
Trend table record
Alarm record
Fixed -time record



Miscellaneous
 
Satety:              
Safety level: Class I, type CF

Dimendion and Weight
Dimendion:      28*42*48cm         
G.Weight:        <6.5KS

Operation Environment
Temperature:    Working 0~+40ºC
Transportation and storage -20~+60ºC
Humidity:       working≤85%
Transportation and storage≤93%
Power:          AC 100-240,50/60Hz
Patient range:    Neonate,pediatric,and adult patients


Accessories supplies
(1) 5 lead ECG cable  
(2) 1 spo2 probes  
(3) 1 NIBP prbe  
(4) 1 temp probe
(5)1 ground connecting liner  
(6) Chest electrode (10pcs/set)
Patient ICU Monitor for Invasive
Patient ICU Monitor for Invasive
Patient ICU Monitor for Invasive

Patient ICU Monitor for Invasive
Patient ICU Monitor for Invasive
Patient ICU Monitor for Invasive

Patient ICU Monitor for Invasive
Patient ICU Monitor for Invasive
Patient ICU Monitor for Invasive
Patient ICU Monitor for Invasive
Patient ICU Monitor for Invasive
Patient ICU Monitor for Invasive