China Hospital Necessary 8.0 Inch Screen Patient Monitor Used in Hospital, Find details about China Patient Monitor, Mindray Patient Monitor from Hospital Necessary 8.0 Inch Screen Patient Monitor Used in Hospital
Power Supply | Adapter | Output 13-20V DC, 5A | |
Voltage | AC100~240V, 50/60HZ | ||
Display | 8" color TFT LED | ||
Resolution | 800*600 pixels | ||
Battery (Pluggable) | Type | Rechargeable lithium battery 14.8V/2200mAh | |
Charge Cycle | ≥500 times | ||
Working time | 5.5 hours | ||
Recorder (Option) | Method | Thermal printer | |
Paper width | 50 mm (1.97 in) | ||
Printing speed | 25/ 50 mm/s | ||
Trace | Max. 2 tracks | ||
Recording way | Real-time Recording | ||
Alarm: | Level | Low, medium and high | |
Indication | Auditory and visual | ||
Alarm volume adjustable | |||
Alarm pause time | 1min, 2min | ||
Parameter alarm type | Latch/ Unlatch |
-Lead mode: 3/5 Leads, I, II, III or I, II, III, AVR, AVL, AVF, V
-Gain: 2.5mm/mV(×0.25), 5.0mm/mV(×0.5), 10mm/mV (×1), 20mm/mV (×2),
-Sweep speed: 6.25 mm/s12.5 mm/s, 25 mm/s, 50 mm/s
-ECG signal range: ±6 mV
-Accuracy: ±1bpm/ ±1%, whichever is greater
-Resolution: 1 bpm
-Leakage Current < 10 μA
-Input impedance: > 5.0Mohm
-CMRR: Diagnostic Mode >90 dB;
Monitor Mode>100dB
Surgery Mode>100dB
-Baseline Recovery:
≤ 5s after defibrillation (Monitor or Surgery mode)
-Bandwidth: Surgery 1 ~ 20Hz
Monitor 0.5 ~ 40 Hz
Diagnostic 0.05 ~ 130 Hz
-Against electrosurgical interference and defibrillation
-Indication of Electrode Separation: Every electrode (exclusive of RL)
-Measure range:
Adult 0bpm; 15 ~ 300 bpm
Pediatric: and Neonate: 0bpm; 15 ~ 450 bpm
-Resolution: 1 bpm
-Accuracy: ± 1% or ± 1bpm, whichever is greater
ST Measurement
-Range: -2.0 ~ +2.0 mV
-Accuracy: -0.8mV~+0.8mV: ±0.02mV or ±10%, whichever is greater
-Other range: unspecified
Respiration
-Method: Impedance between RA-LL,
-Gain: ×0.25, ×0.50, ×1, ×2,
-Respiration Rate: 0bpm, 0 ~ 150 BrPM
-Sweep speed: 6.25 mm/s, 12.5 mm/s, 25mm/s
-Resolution: 1 BrPM
-Accuracy: ±2 bpm or ±2%, whichever is greater
-Apnea Alarm: 10 ~ 40 s
-Measure range:
Adult 0bpm; 15 ~ 300 bpm
Pediatric: and Neonate: 0bpm; 15 ~ 450 bpm
-Resolution: 1 bpm
-Accuracy: ± 1% or ± 1bpm, whichever is greater
ST Measurement
-Range: -2.0 ~ +2.0 mV
-Accuracy: -0.8mV~+0.8mV: ±0.02mV or ±10%, whichever is greater
-Other range: unspecified
Respiration
-Method: Impedance between RA-LL,
-Gain: ×0.25, ×0.50, ×1, ×2,
-Respiration Rate: 0bpm, 0 ~ 150 BrPM
-Sweep speed: 6.25 mm/s, 12.5 mm/s, 25mm/s
-Resolution: 1 BrPM
-Accuracy: ±2 bpm or ±2%, whichever is greater
-Apnea Alarm: 10 ~ 40 s