12kv Indoor High Voltage Lbs-Fuse Combination Load Break Switch ( FLN48 )

China 12kv Indoor High Voltage Lbs-Fuse Combination Load Break Switch (FLN48), Find details about China Load Break Switch, Indoor Load Breaker Switch from 12kv Indoor High Voltage Lbs-Fuse Combination Load Break Switch (FLN48)

Model NO.
FL (R) N48
Structure of Operating
Electric
Certification
CE, ISO9001
Brand
Vacem
Rated Power Load Breaking Current
630A
Rated Short-Time Withstand Current
20ka
Rated Peak Withstand Current
50ka
Rated Pressure of Sf6(20c Psig)
0.045MPa
Manual Operation Maximum Torque
85nm
Trademark
VACEM
Origin
Wenzhou, China
Model NO.
FL (R) N48
Structure of Operating
Electric
Certification
CE, ISO9001
Brand
Vacem
Rated Power Load Breaking Current
630A
Rated Short-Time Withstand Current
20ka
Rated Peak Withstand Current
50ka
Rated Pressure of Sf6(20c Psig)
0.045MPa
Manual Operation Maximum Torque
85nm
Trademark
VACEM
Origin
Wenzhou, China
1.General description
    FL(R)N48 Indoor AC M.V. SF6 load break switch and LBS-fuse combination are used for three-phase AC50/60Hz RMU and power station.The switches are suitable for protecing 12kv power system's on load situation.The switch can switch off the on load current,closed loop current,no load transformer capacity and cable charging current.The switch with fuse combination can cut off any current,when the current is in the range of the rated short-circuit breaking current.They are suitable for the RMU,combined transformer etc.
2.Main technical parameter
ItemUnitData
Rated voltagekV12
Rated currentA630
Rated frequencyHz50/60
Rated power load breaking currentA630
Rated closed-loop breaking currentA630
Rated cable charging breaking currentA10
Rated short-circuit making current(peak)kA50
Rated short-time withstand current durations2
Rated short-time withstand currentkA20
Rated peak withstand currentkA50
Rated short-time power frequency withstand voltagekV42
Rated lightning impulse withstand voltagekV75
Rated short-time power frequency withstand voltage(fracture)kV48
Rated lightning impulse withstand voltage(fracture)kV85
Loop resistanceμΩ≤65
Rated pressure of SF6(20C psig)Mpa0.045
Mechanical life(load break switch)times3000
Mechanical life(earth switch)times2000
Manual operation maximum torqueNm85
Matched fuse typeXRNT(kV)10
3.International fairs12kv Indoor High Voltage Lbs-Fuse Combination Load Break Switch (FLN48)
4. Company show12kv Indoor High Voltage Lbs-Fuse Combination Load Break Switch (FLN48)12kv Indoor High Voltage Lbs-Fuse Combination Load Break Switch (FLN48)12kv Indoor High Voltage Lbs-Fuse Combination Load Break Switch (FLN48)12kv Indoor High Voltage Lbs-Fuse Combination Load Break Switch (FLN48)12kv Indoor High Voltage Lbs-Fuse Combination Load Break Switch (FLN48)