China with Perkins Diesel Engine CE Certificate 20KVA Genset Price, Find details about China Diesel Generator Set, Silent Power Generator from with Perkins Diesel Engine CE Certificate 20KVA Genset Price
Specificates Data:
1. SPECIFICATIONS OF GEN-SET | ||
1.1 | Set Model | GF3P-16 |
1.2 | Prime at 50HZ, 40°C ambient | 16KW 20KVA |
1.3 | Standby at 50HZ, 40°C ambient | 17.6KW 22KVA |
1.4 | Rated Gen-set output | 230/400V 50Hz |
1.5 | Rated Relative humidity | ≤ 60 % |
1.6 | Dimension (L×W×H) | 2100×850×1300mm |
1.7 | Weight | 700kg |
1.8 | Fuel consumption 100% prime load | 5,4 l/hr |
1.9 | Structure of Gen-set | The Gen-set adopt integrative structure, engine is fix on high strength steel basic frame, anti vibration instrument between the engine and basic frame, cooling fan have protecting cap, control cabinet and circuit breaker installed on Gen-set |
1.10 | Control system (Optional) | Basic control panel or Advanced control panel with automatically start-up function and other function |
2. SPECIFICATIONS OF ENGINE | ||
2.1 | Engine Brand | PERKINS |
2.2 | Engine Model | 404D-22G |
2.3 | Governor/Class | Mechanical |
2.4 | Cylinder NO. | 4 |
2.5 | Engine build | Vertical in-line |
2.6 | Fuel spray pattern | Indirect injection |
2.7 | Aspiration | Naturally |
2.8 | Cooling mode | Radiator cooled (enclose water) |
2.9 | Bore and stroke | 84×100mm |
2.10 | Compression ratio | 23·3 : 1 |
2.11 | Displacement | 2.216L |
2.12 | Engine Prime Power at 1500rpm | 18.4KWm |
2.13 | Engine Standby Power at 1500rpm | 20.3KWm |
2.14 | Start-up mode | 12V, electric |
2.15 | Lubricating oil consumption | Lubricating oil consumption less than 10% Fuel consumption |
2.16 | Lubrication oil capacity | 10,6 litres |
2.17 | Coolant capacity - radiator and engine (40°C) | 6,98 litres |
2.18 | Exhaust temp - full load prime | 445°C |
2.19 | Exhaust gas flow - full load prime | 3,64m³/min |
2.20 | Exhaust gas back pressure max | 10,2 kPa |
2.21 | Air intake - engine- full load prime | 1,45m³/min |
2.22 | Standard Air intake temp | 25°C |
2.23 | Fuel type | #0 Diesel (Natural temperature) |
2.24 | Filter system | Adopt whole changeable lubricating oil, fuel filter and air filter |
2.25 | Exhaust system | Adopt industrial high efficiency silencer and flexible bellows |
2.26 | Engine derating - altitude | Above the sea-level 1525m high, a fall of 4% from a rise of 300m. |
2.27 | Engine derating - temperature | Above the ambient temperature 40°C high, a fall of 2% from a rise of 11%. |
3. SPECIFICATIONS OF ALTENATOR | ||
3.1 | Alternator Model | PI 144D |
3.2 | Alternator Type | A.C. Synchronous |
3.3 | Rated Voltage | 230/400V |
3.4 | Rated Frequency | 50HZ |
3.5 | Rated speed | 1500 RPM |
3.6 | Voltage regulation mode | Auto |
3.7 | Alternator voltage regulation | ±0.5% |
3.8 | Exciting mode | Brushless self exciting |
3.9 | Power factor | 0.8 (lagging) |
3.10 | Phase & wires | 3 phase 12 wires |
3.11 | Rated currency | 25.3A |
3.12 | Efficiency | 0.842 |
3.13 | Insulation class | H |
3.14 | Protection class | IP23 |
3.15 | Single load step to NFPA110 | 100% |
3.16 | Standards | IEC34-1,NEMA1 |
3.17 | Max. Ambient Temperature | 40°C |
3.18 | Min. Ambient Temperature | - 15°C |
3.19 | Max. altitude | 1000m |
3.20 | Weight | 133Kg |
Brand | Deepsea/ComAp |
The control module gives digital readouts of: Generator voltage; Output frequency; Engine speed; Battery voltage; Engine hours run. The control module has indicators for failure information: Overspeed/underspeed, Emergency stop Low oil pressure; High water temperature Failure to start Battery charger failure Automatic shutdown occurs under: Low engine oil pressure; High engine water temperature; Overspeed/underspeed; Failure to start after three attempts. |