China Industry Paint Booth/Spray Booths/Paint Spray Booths with Riello Gas Burner Heating, Find details about China Industry Paint Booth, Spray Booths from Industry Paint Booth/Spray Booths/Paint Spray Booths with Riello Gas Burner Heating
ITEMS | SPECIFICATIONS |
Model | Customized Spray Booth for Heavy Machinery |
Design standard | BS EN 13355: 2004 + A1: 2009 BS EN 60204: 2006 + A1: 2009 |
Internal dimensions | 7000 X 4000 X 3000mm (L X W X H) |
External dimensions | 9370 X 5320 X 3700mm (L X W X H) |
Entrance door | 1 set, 3400 X 3000 mm (W X H) |
Personnel door | 1 set, 800 X 2000 mm (W X H) |
Sidewall lighting | 16 sets, each 4 X 18W, 1,152W total, LED lamp |
Brightness | >1,400LUX |
Filters | Pre-filter, ceiling filter, floor filter, exhaust filter |
Air intake | Direct-type turbine fan, 11KW SIEMENS motor |
Air exhaust | Direct-type turbine fan, 11KW SIEMENS motor |
Air volume | 35,000m3/h |
Empty loaded air speed | +/-0.35m/s |
Maximum working temperature | 80ºC |
Heats | 315KW heat exchanger, RS5D gas burner |
Controls | CE standard control box |
Rated power | 28KW |
Airflow • Downdraft airflow for spray and cure • Controlled airflow ceiling | Construction • White pre-coated galvanized steel • Dual-skin insulated panels filled with rock wool, 60mm thick • 600mm high plenum • With exhaust plenum chambers on the left/right/back side • Special item: With overhead opening, which facilitates the conveying of heavy work-piece into the booth by overhead crane |
Doors • 2-wing big entry door • Personnel door with observation window (in the entry door) | Heat • Intake and exhaust motors, 11kw, SIEMENS motor • Gas heating |
Filtration • Pre-filter: G3 grade pre-filter bag filter • Ceiling filter: F5 grade filter cotton, Model SP-600G • Floor filter: Pleated andreae filters + G2 grade fiberglass paint arrestor filters • Exhaust filter: Simple activated carbon filter mat, M type | Controls • PLC controller, pressure gauge Functions: Painting, heating painting, flash, baking, cooling, lighting, emergency stop switch, failure indication, over-temperature alarm indication, fan and heating system interlock |