China Steel Refineries Production Use Harmful Proof Fixed Co Gas Detector, Find details about China Co Gas Detector, Fixed Co Alarm from Steel Refineries Production Use Harmful Proof Fixed Co Gas Detector
Power supply | 24VDC |
Output signal | 4-20mA standard industrial signal output |
Operating temperature | -20°C~+50°C |
Display | Backlight LED |
Relative humidity | 15%~90% RH (non-condensing) |
Atmospheric pressure | 86~106Kpa |
Explosion-proof grade | Exd IICT6 |
Warranty | 1 year |
No. | Detection gas | Range | Accuracy | 90% response time | Min readout | Low/high alarm |
1 | PH3 | 0-5-2000ppm | ±5%(F.S) | ≤25s | 0.01ppm | 0.3/5ppm |
2 | O2 | 0-30% | ±5%(F.S) | ≤15s | 0.1%vol | 18.0%/23.0% |
3 | LPG(LEL gas) | 0-100%LEL | ±5%(F.S) | ≤5s | 1%LEL | 25.0%/50.0%LEL |
4 | CO | 0-1000 ppm | ±5%(F.S) | ≤25s | 1 ppm | 50ppm/100ppm |
5 | H2S | 0-100 ppm | ±5%(F.S) | ≤30s | 1 ppm | 10ppm/20ppm |
6 | CH4 | 0-100%LEL | ±5%(F.S) | ≤5s | 1%LEL | 25.0%/50.0%LEL |
7 | NH3 | 0-100ppm | ±5%(F.S) | ≤50s | 1 ppm | 25 ppm /50 ppm |
8 | O3 | 0-20ppm | ±5%(F.S) | ≤60s | 0.01ppm | 0.2ppm/0.4ppm |
9 | CI2 | 0-20 ppm | ±5%(F.S) | ≤30s | 0.1 ppm | 1 ppm /10 ppm |
10 | H2 | 0-1000 ppm | ±5%(F.S) | ≤60s | 1 ppm | 50 ppm /100 ppm |
11 | SO2 | 0-100 ppm | ±5%(F.S) | ≤30s | 0.1 ppm | 2 ppm /10 ppm |
12 | NO | 0-250 ppm | ±5%(F.S) | ≤60s | 1 ppm | 25ppm/50 ppm |
13 | NO2 | 0-20 ppm | ±5%(F.S) | ≤25s | 0.1 ppm | 3ppm/10ppm |
14 | Infrared CO2 | 0-5%vol | ±5%(F.S) | ≤60s | 0.1%vol | 1%vol/2%vol |
15 | Infrared CH4 | 0-5%vol | ±5%(F.S) | ≤60s | 0.1%vol | 0.1%vol/0.15%vol |
16 | Infrared C3H8 | 0-5%vol | ±5%(F.S) | ≤60s | 0.1%vol | 0.1%vol/0.15%vol |