AC Hipot Impulse High Voltage Test System Surge Voltage Generator for High Voltage Power Equipment

China AC Hipot Impulse High Voltage Test System Surge Voltage Generator for High Voltage Power Equipment, Find details about China Impulse Generator, High Voltage Tester from AC Hipot Impulse High Voltage Test System Surge Voltage Generator for High Voltage Power Equipment

Model NO.
SXCF
Rated Energy
10kj or at Customized
Nominal Voltage
200kv or at Customized
Impulse Capacitance
0.5UF or at Customized
Each Stage
100kv 0.25UF or at Customized
Frequency
50Hz
Working Duration
Above 8 Hours
Trademark
Sansion
Transport Package
Plywood Case
Specification
ISO9001 SGS
Origin
Wuhan, China
HS Code
9030339000
Model NO.
SXCF
Rated Energy
10kj or at Customized
Nominal Voltage
200kv or at Customized
Impulse Capacitance
0.5UF or at Customized
Each Stage
100kv 0.25UF or at Customized
Frequency
50Hz
Working Duration
Above 8 Hours
Trademark
Sansion
Transport Package
Plywood Case
Specification
ISO9001 SGS
Origin
Wuhan, China
HS Code
9030339000

AC Hipot Impulse High Voltage Test System Surge Voltage Generator for High Voltage Power EquipmentAC Hipot Impulse High Voltage Test System Surge Voltage Generator for High Voltage Power Equipment
 Impulse Voltage Generator for  Lightning Test

General Information:
This impulse test system is used for carrying out standard lightning impulse voltage full wave and operation wave tests on HV apparatus such as power capacitors, clearance, bushings, power transformers and CT/PT at 10kV or below.

Main Parameters for System

Nominal voltage: ±200kV

Impulse capacitance: 0.5µF
 
Number of stages: 2

Rated stage voltage: ±100kV

Rated energy: 10kJ

Rated stage capacitance: 1µF(each impulse capacitor 1µF at 100kV, total 2pcs)

Impulse voltage waveform: generated when load capacitance is 300-3000pF.T1=1.2µs±30%, T2=50µs±20%, standard lightning impulse voltage full waveform of peak voltage deviation≤3%;
Standard operation waveform 250±20%/2500±60%. These 2 Impulse voltage waveform parameters and error are accorded with national requirements of GB311.1and GB16927.1 standard and IEC standard.

Voltage utilization factor: Standard lightning impulse voltage waveform ≥90% when load capacitance is below 1000pF, standard operation impulse voltage waveform≥80% when load capacitance is below 2000pF. Standard operation impulse voltage waveform ≥70%.

Locking range: level voltage is within the range of 20%-100% rated voltage, positive and negative locking range no less than 25%.

Out-of-control rate of synchronous discharge: <5%

Min. output voltage: ≥±20% of rated voltage.

Instability of discharge voltage: <±1.0%

Continuous time: Above 2/3 of rated voltage, continuous working when charge and discharge once every 120s. Below 2/3 of rated voltage, continuous working when charge and discharge once every 60s.

Above information for reference using, please contact us for further technical details.

Impulse Voltage Generator

More details please contact Sansion Power by email for further information.
AC Hipot Impulse High Voltage Test System Surge Voltage Generator for High Voltage Power EquipmentAC Hipot Impulse High Voltage Test System Surge Voltage Generator for High Voltage Power EquipmentAC Hipot Impulse High Voltage Test System Surge Voltage Generator for High Voltage Power Equipment