China RS485 Modbus Split Display Easy Programmable Electromagnetic Flowmeter Drink Water Flow Meter, Find details about China Drink Water Electromagnetic Flowmeter, RS485 Modbus Drink Water Flowmeter from RS485 Modbus Split Display Easy Programmable Electromagnetic Flowmeter Drink Water Flow Meter
Item | Description |
Type | Integrated Type |
Available Medium | Conductive Liquid Fluid |
Range of Diameter | DN6-DN2000 1/4"-80" |
Accuracy | 0.5% (0.2% Optional) |
Conductivity | >5μs/cm |
Velocity Range | 0.5-10m/s |
Medium Temperature | -20-60ºC(Neoprene Rubber Liner) |
-20-60ºC(Polyurethane Rubber Liner) | |
-20-120ºC(PTFE Liner) | |
-20-160ºC(F46 Liner) | |
Rated Pressure Range | PN6-PN40 (High Pressure Customize Available) |
PN40 (DN6-DN15) | |
PN16(DN20-DN250) | |
PN10(DN300-DN1000) | |
PN6(DN1200-DN2000) | |
Available Electrode | SS316L |
Titanium | |
HasteAlloy B | |
HasteAlloy C | |
Tantalum | |
Platinum-Iridium Alloy | |
Tungsten Carbide | |
Body Material | Carbon Steel with Protection Varnish |
Stainless Steel 304 | |
Stainless Steel 316/316L | |
Connection | Flange(GB,DIN,ANSI,JIS,HG or Customize) |
Wafer Flange(For High Pressure Condition) | |
Thread(NPT,BSP,GB or Customize) | |
Sanitary Tri-Clamp(DIN,3A,ISO Standard) | |
Straight Pipe Section | 5*DN Upstream .3*DN Downstream |
Display | LCD Display with Adjusting Button |
Power Supply | 24VDC(8-36VDC) |
220VAC(85-270VAC) | |
3.6V Lithium Battery(Life Time 2-3 Years) | |
Signal Output | 4-20mA |
Frequency/Pulse | |
Communication Protocol | RS485 MODBUS |
HART | |
Electricity Entry | M20*1.5 |
1/2" NPT | |
Protection Grade | IP65 |
IP67 | |
IP68 | |
Explosion Proof Grade | ExdIICT4(Sensor) Exd{ia}IICT5(Transmitter) |