Compression Connector Pica Grounded for Cable #2

China Compression Connector Pica Grounded for Cable #2, Find details about China Compression Connector, Compression Clamp from Compression Connector Pica Grounded for Cable #2

Model NO.
C2G
HS Code
73269090
Model NO.
C2G
HS Code
73269090
Compression connector pica grounded
for cable #2
Compression Connector Pica Grounded for Cable #2
 
4Material name Aluminum compression connector 
Type H, 3/0 AL 3/0 ACSR 
5Raw material Bimetallic aluminum pressure stretched, with high degree of hardness Rockwell RH30, high conductivity 1100-0
6Rules ANSI C119.4, UL486 A
7Quality certificate ISO 9001
8Kind H
9Main gauges 3/0 - 4/0 ACSR
10Caliber derivation 3/0 - 4/0 ACSR
11Type of conductor to be connected Aluminum, copper and ACSR
12Slot with rust inhibitor Yes
13Height approx.inch(mm)1-1 / 2 (38.10)
 Length approx.inch(mm)2- 1/2 (63.5)
14Width approx.inch(mm)6/7 (21.77)
15External Comma The external part of the connector should be placed 
with a bath of metallic stamp, in order to 
prevent environmental corrosion to moisture and air on the contact surface 
16Inhibitory compound Each connector must present in the slot a 
Composite of the oxide and galvanic corrosion 
17Identification mark Each connector should be marked with the 
manufacturer's symbol, catalog number, 
Application driver range, number of die to occupy. When this information is not possible to present in the body of the connector, it will be printed on the connector bag except for the manufacturer's brand and name, which must necessarily be indicated on the body of the connector 
18Packaging Each connector should be individually 
packed in a high plastic bag 
resistance duly sealed for intempere, in order to prevent external agents from damaging it and causing premature oxidation. 


kV to 38 kV grounded systems with 100 or 200 A nominal currents.

 
4Connector name Compression connector grounding pin for cable # 2
5Raw material Body: Electrolytic copper manufactured by extrusion, high resistance- With inhibitor
6Driver to press Copper
7Driver to connect on the pike 
grounding 
AWG2
8Applied standards ANSI C 119.4, IEEE837
9Quality certificate ANSI C 119.4, IEEE837
10Main admissible diameterinch(mm)5/8 (15.8)
11Permissible diameterinch(mm)0.29 to 0.23 (7.4 to 5.8)
12DN-DS certificate Attach acceptance certificate and 
homologation 
13Identification mark Each connector should be 
marked on the body with the 
manufacturer symbol, catalog number, application driver ranges and die number to occupy with the hydraulic tool for installation 
14Packing The connectors should be 
in a package that indicates in 
its exterior the range of application and prevent external agents from damaging it and causing premature oxidation 


Compression Connector Pica Grounded for Cable #2
Especially designed to protect transformers, capacitors, cables or lines.
It is robust construction, made of rigorously tested material, will interrupt all faults under the
most severe conditions, maintaining mechanical and electric characteristics.
Compression Connector Pica Grounded for Cable #2Compression Connector Pica Grounded for Cable #2Compression Connector Pica Grounded for Cable #2Compression Connector Pica Grounded for Cable #2Compression Connector Pica Grounded for Cable #2Compression Connector Pica Grounded for Cable #2Compression Connector Pica Grounded for Cable #2Compression Connector Pica Grounded for Cable #2Compression Connector Pica Grounded for Cable #2Compression Connector Pica Grounded for Cable #2
The inserts, hardware and structural bolts and nuts are made from heavy galvanized steel.
The Fuse Cutout type OEI can be applied on all three-phase system rated at or below the maximum
operational rating of the cutout.
ProductD  Bracket
Test ItemsTest ContentTest Result 
Sample
1
Sample 
2
Sample 
3
Sample
4
Sample
5
Remarks
Visual  InspectionCrack1)      Passed Mark"√"
2)  Not Passed Mark"×"
Test Conclusion:
Stoma Trachoma
Fins
Burr
Galvanizing thicknessμm1)      Passed Mark"√"
2)      Not Passed Mark"×":
Test Conclusion:
Mechanical CharacteristicsMechanical Load1)Passed Mark"√"
2)Not Passed Mark"×"
Test Conclusion:
InspectorDate:  02. March,2011                        Approved: