Halogen Free Flame Retardant Charging Pile Cable TPE
Specification:
Items | Test Method | Unit | standard Range |
Hardness | ASTM D-2240 | Shore A | 60-85 |
Density | ASTM D-792 | g/cm3 | 1.0-1.1 |
Tensile Strength | ASTM D-412 | MPa | >10 |
Elongation at Break | ASTM D-412 | % | >250 |
Temperature resistant range | UL1581 | ºC | 70-105 |
Flame Retardant Performance | VW-1 | pass | UL1581 |
Oil Resistance | IRM902# and903# | pass | UL62 |
Application:
Suitable for the charging pile equipment wire and portable charging wire of the electrical vehicles
High Effective oil resistant, flexible Non-halogenated flame retardant TPE granules for the charging pile cable of electrical vehicles
Characteristics:
Excellent oil resistance, complied with the oil testing of IRM902, diesel and petrol
Excellent wear resistance and high tear strength
High mechanical strength
No cracking under both high and low temperature
High effective flame retardant performance, passing UL1581VW-1 test
Water resistant, ozone resistant, anti-UV, no cracking under the testing of grinding
Excellent physical and chemical properties as well as favorable mechanical and electrical performance
Specification:
Items | Test Standard | Unit | standard Range |
Hardness | ASTM D-2240 | Shore A | 75-90 |
Density | ASTM D-792 | g/cm3 | 1.2-1.3 |
Tensile Strength | ASTM D-412 | MPa | >12 |
Elongation at Break | ASTM D-412 | % | >250 |
Temperature resistant range | UL1581 | ºC | 80-105 |
Flame Retardant Performance | UL1581 | / | VW-1 |
Oil Resistance | UL62 | / | Diesel, petrol |
Application:
Suitable for the charging pile equipment cable and portable charging cable (spring wire series) of the electrical vehicles as well as the internal cable (battery line) / electrical line
High temperature resistant, high oil resistant Non-halogenated flame retardant TPE granules for the charging pile cable of electrical vehicles
Characteristics:
High temperature resistant, 125ºC temperature rating as defined by UL1581
Excellent oil resistance, complied with the oil testing of IRM902, diesel and petrol
Excellent flex fatigue resistant and creep resistant ability
High effective flame retardant performance, passing UL1581VW-1 test
Water resistant, ozone resistant, anti-UV, no cracking under the testing of grinding.
Excellent physical and chemical properties as well as favorable mechanical and electrical performance
Specification:
Items | Test Standard | Unit | standard Range |
Hardness | ASTM D-2240 | Shore A | 80-95 |
Density | ASTM D-792 | g/cm3 | 1.1-1.2 |
Tensile Strength | ASTM D-412 | MPa | >10 |
Elongation at Break | ASTM D-412 | % | >250 |
Temperature resistant range | UL1581 | ºC | 125 |
Flame Retardant Performance | UL1581 | / | VW-1 |
Oil Resistance | UL62 | / | Diesel, petrol |
Application:
Suitable for the charging pile equipment cable and portable charging cable, internal cable (battery line) / electrical line of the electrical vehicles as well as the internal cable of the vehicles
LSHF TPE granules for the charging pile cable of electrical vehicles
Characteristics:
Low smoke density and high light transmission rate
Excellent chemical corrosive resistance as well as acid and alkali resistant ability
Water resistant, ozone resistant, anti-UV, no cracking under the testing of grinding
Excellent stress cracking resistance and scratch resistance
Excellent processability without the requirement of irradiation crosslinking
Excellent physical and chemical properties as well as favorable mechanical and electrical performance
Environmental friendly, complies with ROHS, PAHS, REACH and so on
Specification:
Items | Test Standard | Unit | standard Range |
Hardness | ASTM D-2240 | Shore A | 90-95 |
Density | ASTM D-792 | g/cm3 | 1.4-1.5 |
Tensile Strength | ASTM D-412 | MPa | >10 |
Elongation at Break | ASTM D-412 | % | >150 |
Light transmission | IEC61034 | % | >60 |
Oil resistant | UL62 | / | IRM902 |
solvent resistance | / | / | hydrochloric acid, ammonia water, alkali |
Application: