2019 China Quality Switching Power Supply Power Adapter, Find details about China Switching Power Supply, AC-DC Adaptor from 2019 China Quality Switching Power Supply Power Adapter
Model: | YS250 |
Power: | 250W max. |
Input: | 100-240VAC, 50/60Hz |
Output Voltage: | 12-48V |
Output Current: | 0.1-18A |
Input current: | 4A max. |
Inrush Current: | 65 Amps max. at 230VAC/50Hz,full load |
Leakage Current: | 1.5mA Max. at 264VAC input |
Energy Efficiency Level VI : | CoC 5 / DoE 6 / CEC VI |
No Load Power Consumption : | <0.15W |
Protections: | Short Circuit /Over Current /Over Voltage |
Short Circuit Protection (SCP): | Protection to Zero Voltage |
Over Voltage Protection (OVP): | ≤Vout*150% |
Over Current Protection (OCP): | 110%-180% |
Working TEMP.: | -20°C-50°C |
Working Humidity: | 5%-90% RH non-condensing |
Storage TEMP.,Humidity and altitude: | -40ºC ~+70°C ambient temperature and a 5% to 95% relative humidity range throughout an altitude range of -60 meters to +5000 meters AMSL. |
Input Plug: | EU,US,UK,AU etc. type according to customer's choice |
Certificates and approvals: | UL,GS,CE,EMC,SAA,FCC,CB,PSE,CCC,RoHS,REACH |
EMI EMISSION: | Radiation Test&Conduction Test: EN 55022/FCC Part 15 Harmonic Test : EN 61000-3-2 Flicker Test : EN 61000-3-3 |
EMS IMMUNITY: | ESD Test:EN 61000-4-2 RS Test:EN 61000-4-3 EFT Test:EN 61000-4-4 Surge Test:EN 61000-4-5 CS Test:EN 61000-4-6 DIP Test:EN 61000-4-11 |
MTBF: | 100000 hours minimum at full load at 25ºC ambient |
Life: | 3-5 years alternative |
Dimension: | 238*98*45mm |
Weight: | 1350g |
Packing: | 20PCS/CTN,42.5*42*20cm |
Model: | YS250-1201800 | YS250-1501500 | YS250-2001200 | YS250-2401000 | YS250-3606900 | YS250-4805200 |
DC Voltage: | 12V | 15V | 20V | 24V | 36V | 48V |
Rated Current: | 18A | 15A | 12A | 10A | 6.9A | 5.2A |
Current Range: | 0-18A | 0-15A | 0-12A | 0-10A | 0-6.9A | 0-5.2A |
Rated Power: | 216W | 225W | 240W | 240W | 248.4W | 192W |
Ripple & Noise(max.): | 120mVp-p | 150mVp-p | 200mVp-p | 240mVp-p | 240mVp-p | 300mVp-p |
Voltage Tolerance: | ±5% | ±5% | ±5% | ±5% | ±5% | ±5% |
Line Regulation: | ±3% | ±3% | ±3% | ±3% | ±3% | ±3% |
Load Regulation: | ±5% | ±5% | ±5% | ±5% | ±5% | ±5% |
Efficiency: | 89% | 89% | 89% | 89% | 89% | 89% |
Setup,Rise,Hold up time: | 1.5 second max./40 MS max./15 MS max. at 115VAC input and output max. load. | |||||
PF | >0.95 230V AC FULL LOAD | |||||
HI-POT | 3000V AC 60S 5mA |