Made in China 500 kVA Diesel Generator, Find details about China Generator, Diesel Generator Set from Made in China 500 kVA Diesel Generator
WEIGHT AND DIEMENSIONS | |
Size of Genset Open Type | 3300*1360*1800mm |
Weight of Genset OpenType | 3100KG |
Size of Genset Silent Type | 4000*1800*2150mm |
Weight of Genset Silent Type | 4900KG |
GENSET POWER | |||||
Voltage | Hz | Phase | Power Factor | Current | Power |
120/208V | 60HZ | 3 | 0.8 | 1388A | 500KVA |
ENGINE DATA | |
Manufacturer/Model | Cummins QSZ13-G2 |
No. Of Cylinder | 6 Cylinders |
Cylinder Arrangement | L Type |
Cycle | 4 Stroke |
Aspiration | Turbocharged Air/water cooling |
Combustion System | Electronic fuel injection |
Bore×Stroke | 130mm x163mm |
Displacement | 13 L |
Compression Ratio | 17:1 |
Prime Power/Speed | 400KW/500KVA@ 1800rpm |
Speed Governor | Electronic |
Cooling System | Forced water cooling cycle |
Steady speed droop | ≤1% |
Starter Motor | DC24V |
FUEL SYSTEM | |
Fuel Type | Diesel |
Fuel Consumption at 100% Load | 207gram/kw.h |
LUBE OIL SYSTEM | |
Total lubrication system capacity | 28L |
Lube Oil Type | CD15W Class and Above |
COOLING SYSTEM | |
Coolant Capacity-Engine only | 85L |
Max Tank Temperature | 104ºC |
Thermostat | 83-95ºC |
ALTERNATOR DATA | |
Manufacturer / Model | Stamford HCI544C1 |
Prime power | 450KW/560KVA |
Frequency/speed | 60HZ/1800rpm |
Exciter type | Single bearing, Brushless, Self-excited |
Power factor | 0.8 |
Voltage adjust range | ≥5% |
Insulation Grade | H |
Pole No. | 4 |
Protection Grade | IP23 |
Phase / wire | 3 phase 4 wires |
CONTROL PANEL | |
The ComAp MRS10 is an Digital Control Module suitable for a wide variety of single, diesel or gas, gen-set applications. Monitoring an extensive number of engine parameters, the module will display warnings, shutdown and engine status information on the back-lit LCD screen and illuminated LEDs. | |
The control module gives digital readouts of: Generator voltage; Output frequency; Engine speed; Battery voltage; Engine hours run. The control module has indicators for failure information: Over speed/Low speed, Emergency stop Low oil pressure; High water temperature Failure to start Battery charger failure Automatic shutdown occurs under: Low engine oil pressure; High engine water temperature; Over speed/Low speed; Failure to start after three attempts. |
Main Engine Brand Introduction | ||||||
Generator Brand | Generator Power(KW) | Generator Power(Kva) | Consumption Diesel(l/hr) | Voltage(V) | Frequency(HZ) | Speed(RPM) |
Cummins Series | 16-1560 | 20-1950 | 5.7-339.9 | 230/400 | 50/60 | 1500/1800 |
Pks Series | 8-2000 | 10-2250 | 3-529 | 230/400 | 50/60 | 1500/1800 |
Volvo Series | 68-544 | 85-680 | 16-133 | 230/400 | 50/60 | 1500/1800 |
MTU serirs | 520-2600 | 650-3250 | 126.5-623.8 | 230/400 | 50/60 | 1500/1800 |
Mitsubishi Series | 480-2000 | 600-2500 | 125-525 | 230/400 | 50/60 | 1500/1800 |
Yangdong series | 7.2-48 | 9-65 | <240 | 230/400 | 50/60 | 1500/1800 |
SDEC series | 48-800 | 60-1000 | 195-225 | 230/400 | 50/60 | 1500/1800 |
Other series ( Container type / Marine series etc. ) |