10kv Tan Delta Transformer Capacitance & Dissipation Factor Dielectric Loss Tester

China 10kv Tan Delta Transformer Capacitance & Dissipation Factor Dielectric Loss Tester, Find details about China Hz 2000 H Dissipation Factor Tester, Zc-221 Transformer Tan Delta Tester from 10kv Tan Delta Transformer Capacitance & Dissipation Factor Dielectric Loss Tester

Model NO.
HZ-2000H
Control
Manual Control
Weight
0-100Kg
Power Source
AC220V
Resolution
Maximum 0.001PF, 4 Valid Figures.
Test Current Range
10μa-1A
Maximum Output Current
200mA
Environment Temperature
-10ºC-50ºC
Relative Humidity
<90%
Overall Dimension
460×360×350mm
External Hv
3PF-1.5μf/10kv 60PF-30μf/0
Tgδ Range
Unlimited, 0.001% Resolution
Set Voltage Range
0.5-10kv
Name
Transformer Tan Delta Tester
Trademark
HuaZheng
Transport Package
Wooden Box with Foam Inside
Specification
CE/ISO/IEC
Origin
Hebei, China
HS Code
9030899090
Model NO.
HZ-2000H
Control
Manual Control
Weight
0-100Kg
Power Source
AC220V
Resolution
Maximum 0.001PF, 4 Valid Figures.
Test Current Range
10μa-1A
Maximum Output Current
200mA
Environment Temperature
-10ºC-50ºC
Relative Humidity
<90%
Overall Dimension
460×360×350mm
External Hv
3PF-1.5μf/10kv 60PF-30μf/0
Tgδ Range
Unlimited, 0.001% Resolution
Set Voltage Range
0.5-10kv
Name
Transformer Tan Delta Tester
Trademark
HuaZheng
Transport Package
Wooden Box with Foam Inside
Specification
CE/ISO/IEC
Origin
Hebei, China
HS Code
9030899090
10kV Tan Delta Transformer Capacitance & Dissipation Factor Dielectric Loss Tester


10kv Tan Delta Transformer Capacitance & Dissipation Factor Dielectric Loss Tester10kv Tan Delta Transformer Capacitance & Dissipation Factor Dielectric Loss Tester10kv Tan Delta Transformer Capacitance & Dissipation Factor Dielectric Loss Tester10kv Tan Delta Transformer Capacitance & Dissipation Factor Dielectric Loss Tester10kv Tan Delta Transformer Capacitance & Dissipation Factor Dielectric Loss Tester

I.Description

Dielectric loss measurement is a very basic method in the insulation test, which can effectively find the overall moisture deterioration and deterioration of electrical equipment insulation, as well as local defects. It is widely used in electrical engineering, electrical equipment installation, handover and preventive testing. The measurement of dielectric loss of transformers, transformers, reactors, capacitors, bushings, arresters, etc. is the most basic method to measure the insulation performance. The dielectric loss tester breaks through the traditional bridge measurement method, adopts the frequency conversion power supply technology, uses the single-chip microcomputer, and modern electronic technology to perform automatic frequency conversion, analog-to-digital conversion and data calculation; achieves strong anti-interference ability, fast test speed and high precision. Fully automatic digitalization and easy operation; power supply adopts high-power switching power supply, output 45Hz and 55Hz pure sine wave, automatic pressure, can provide voltage up to 10kV; automatically filter out 50Hz interference, suitable for large electromagnetic interference such as substation testing on the spot. It is widely used in dielectric loss measurement of transformers, transformers, bushings, capacitors, arresters and other equipment in the power industry.

II.Technical Indicators
Accuracy: Cx: ± (reading × 1% + 1pF)
Tgδ: ± (reading × 1% + 0.00040)
Anti-interference index: Frequency conversion anti-interference, can still achieve the above accuracy under 200% interference
Capacitance range: Internal high pressure: 3pF ~ 60000pF / 10kV 60pF ~ 1μF / 0.5kV
Applied high pressure: 3pF ~ 1.5μF / 10kV 60pF ~ 30μF / 0.5kV
Resolution: up to 0.001pF, 4 significant digits
Tgδ range: No limit, resolution 0.001%, three kinds of samples of capacitance, inductance and resistance are automatically recognized.
Test current range: 10μA ~ 5A
Internal high voltage: Set voltage range: 0.5~10kV
Maximum output current: 200mA
Lifting and lowering mode: The voltage is set freely. For example, 5123V.
Test frequency: 40-70Hz single frequency can be set freely. For example, 48.7Hz.
50±0.1Hz to 50±10Hz automatic double conversion random setting.
60±0.1Hz to 60±10Hz automatic double conversion can be set freely.
Frequency accuracy: ±0.01Hz
External high voltage: Maximum test current 5A during positive wiring, power frequency or frequency conversion 40-70Hz
The maximum test current is 10kV/5A when reverse wiring, power frequency or frequency conversion 40-70Hz
CVT self-excited low voltage output: output voltage 3 ~ 50V, output current 3 ~ 30A
10kv Tan Delta Transformer Capacitance & Dissipation Factor Dielectric Loss Tester

III.Company Information

HuaZheng Electric Manufacturing (Baoding) Co.,Ltd is the supplier of the State Grid in China.It means we are the supplier of the Chinese Government.And our products spread throughout the whole China.
What's more, our customers come from different countries like America, England, Bulgaria, Brazil, Chile, Malysia, Vietnam and so on.
Our main products are Insulation Oil Tester, Cable Fault Locator, Power Quality Analyzer, High Voltage Generator, High Voltage Capacitor, Testing Transformer and so on.
5kv Megger Insulation Resistance Tester, Digital Megger

IV.Customer Visit
10kv Tan Delta Transformer Capacitance & Dissipation Factor Dielectric Loss Tester


V.Exhibition
10kv Tan Delta Transformer Capacitance & Dissipation Factor Dielectric Loss Tester


VI.Similar Recommendation

10kv Tan Delta Transformer Capacitance & Dissipation Factor Dielectric Loss Tester