600kw 750kVA Diesel Generator Set 10.5kv 11kv Medium Voltage

China 600kw 750kVA Diesel Generator Set 10.5kv 11kv Medium Voltage, Find details about China High Voltage Generator, 50Hz High Voltage Generator from 600kw 750kVA Diesel Generator Set 10.5kv 11kv Medium Voltage

Model NO.
HGM
Conditions of Use
Land Use
Usage
Common Units
Landuse Type of Unit
Low Noise
Excitation Mode
AC Rotating Exciter
Frequency&Speed
50Hz&1500rpm
Voltage Range
3kv-13.8kv
Warranty
1 Year or 1000hours
Application Area
Power Plant, High Voltage, Black Start
Engine Standard
ISO9001, GB/T2820-97, ISO8528
Alternator Standard
BS5000, VDE0530, NEMA Mg1-32, IEC34, IEC60034, As1
Engine Model
Googol High Voltage Diesel Engine
Controller
Deif, Deep Sea, Comap, etc
Load Mode
Fixed Output or Auto Load Sharing
Alternator
Marathon, Engga, Leroy Somer, Mecc Alte
Trademark
Honny
Transport Package
Poly Plastic Firm, Wooden Box or as Need
Specification
ISO8528
Origin
Guangdong, China
HS Code
85021300
Model NO.
HGM
Conditions of Use
Land Use
Usage
Common Units
Landuse Type of Unit
Low Noise
Excitation Mode
AC Rotating Exciter
Frequency&Speed
50Hz&1500rpm
Voltage Range
3kv-13.8kv
Warranty
1 Year or 1000hours
Application Area
Power Plant, High Voltage, Black Start
Engine Standard
ISO9001, GB/T2820-97, ISO8528
Alternator Standard
BS5000, VDE0530, NEMA Mg1-32, IEC34, IEC60034, As1
Engine Model
Googol High Voltage Diesel Engine
Controller
Deif, Deep Sea, Comap, etc
Load Mode
Fixed Output or Auto Load Sharing
Alternator
Marathon, Engga, Leroy Somer, Mecc Alte
Trademark
Honny
Transport Package
Poly Plastic Firm, Wooden Box or as Need
Specification
ISO8528
Origin
Guangdong, China
HS Code
85021300
600kw 750kVA Diesel Generator Set 10.5kv 11kv Medium Voltage

600kW 750kVA Diesel Generator set 10.5kV 11kV Medium Voltage


Googol High voltage series generator sets, power range is from 800kVA to 5000kVA, standard voltage or high voltage generating system.
 
Alternator voltage: 3300V, 6300V, 10500V, 3600V, 6600V, 11000V, 13800V
Frequency: 50Hz or 60Hz
Speed: 1500rpm, 1800rpm, 1200rpm, 1000rpm according to the engine brand

Performance Feature:
Engine and alternator shall be mounted on a same frame steel skid.
Small size, low weight, easy to operating, installation and maintenance.
Good Quality diesel engine.
World famous brand AC alternator: Stamford, Marathon, Leroy Somer, MVC, Engga.
Advanced and reliable control module: Key start, Auto start, Remote control by PC with RS232/485
Full range protect function and alarm shutdown feature.
Standard Control System: Deepsea 7320 AMF
Mains 3 phases VPh-N L1-N L2-N L3-N
Mains 3 phases VPh-pH L1-L2 L2-L3 L3-L1
Mains frequency Hz (L1)
Gen 3 phases VPh-N L1-N L2-N L3-N
Gen 3 phases VPh-pH L1-L2 L2-L3 L3-L1
Gen 3 phases current I1 I2 I3
Gen frequency Hz (L1)
Gen total apparent power ∑ A
Gen total active power ∑ P
Gen power factor PF (AV)
Genset speed RPM (signal from generator voltage frequency)
Engine oil pressure Bar (signal from engine P-sensor)
Engine coolant temperature (signal from engine T-sensor)
Battery voltage VDC
Genset Running hour Hour
Standard Accessory:
Common steel base frame, anti-vibrator, Exhaust silencer, Flexible pipe, Battery connecting wires, Operation manual and document.
Optional Accessory:
Circuit breaker, Starting Battery, Engine coolant and oil heater, Alternator space heater, Cooling for heat exchanger, Control system with RS232/485 communication interface, Battery charger by main supply, Fuel-water separator, Daily fuel tank, ATS and paralleling system, Soundproof Canopy and Moving Trailer.
Usage: Power plant, black start, emergency standby, large factory, data center, mining plant

Let's achieve our goal together, Using power to kindle the dream of human.
Engine Model PTAA1780G1-HV
Speed rpm1500
Frequency Hz50
Rating Output  
Engine Standby Output  ( LTP)kW738 
Engine Prime Output (PRP)kW674 
Engine Continuous Power (COP)kW610 
Fan Quantity 1
Fan Reduction kW36
Single Fan Reduction kW36 
All Fans ReductionkW36
Engine Net Standby Output  ( LTP)kW702 
Engine Net Prime Output  (PRP)kW638 
Engine Net  Continuous Output  (COP)kW574 
BMEP for Standby Output bar20.20 
BMEP for Prime Output bar18.44 
BMEP for Continuous Outputbar16.70 
Typical Generation Standby OutputkVA825
Typical Generation Standby OutputkW660
Typical Generation Prime OutputkVA750
Typical Generation Prime OutputkW600
Typical Generation Continuous OutputkVA675
Typical Generation Continuous OutputkW540
Typical  Alternator Efficiency 94.0%
Voltage of Genset 11000
MECC alte Generator's Model *
MARATHON Generator's Model MXH600-4
Coupler Model ZL7-01
Power Factor 0.8
Speed droop (static) elect. Gov. 0-5%
Governing standards to ISO 8528 Parts 1 and 5 G3
Max. step load acceptance, 1st step ( % Prime Output ) 60%
Basic Performance Datasheet  
Aspiration Type Turbocharger, air-air aftercooler
Injection Type Direct Injection
Configuration Vee
No. of Cylinders 16
Displacement l29.2
Bore mm128
Stroke mm142
Compression Ratio 14.6:1
Piston Speed m/s7.1
Rotation Direction (from flywheel) Counter Clockwise
Number of Flywheel Teeth  204 
Flywheel House Size SAE0-18
Lubrication System  
Lube Oil Specification API-CF4
Oil Capacity l72
Max. Permissible Oil Temperature °C110
Oil Pressure Warning kPa200
Oil Pressure Shutdown kPa160
Cooling System  
Coolant Capacity for Engine l26
Max. Permissible Temperature  °C90
Max. Coolant Warning Temperature  °C95
Max. Coolant Shutdown Temperature  °C105
Thermostat Open Temperature °C71
Radiator Cooling Flow  m³/min1512
Flow of Coolant pump m³/h51.96 
Flow of Aftercooler pump m³/h*
Heat dissipation (engine radiator)kW353 
Heat dissipation (CAC)kW186 
Heat dissipation (convection)kW54 
Mode of Radiator(cooper core , 40 C  environment's temp ) 6300300
Fuel System  
Governor Type Electrical 
Engine Output at genset prime outputkW674 
Fuel Consumption at 25% of  genset prime outputl/h45.52 
Fuel Consumption at 50% of genset prime outputl/h82.05 
Fuel Consumption at 75% of genset prime outputl/h120.88 
Fuel Consumption at 100% ofgenset prime outputl/h161.71 
Lowest Fuel Consumption Ratiog/kW.hr198.85 
Intake & Exhaust System ( On Standby Output )  
Combustion Air Consumption m³/min55.36 
Max. Intake Restriction KPa5
Exhaust Temperature (Before Turbo)°C688
Exhaust Temperature (After Turbo)°C493
Max. Exhaust Back PressureKpa5
Exhaust Gas Flow  m³/min67.66 
Exhaust Flange Diameter mm2*150
Electrical System  
Charging Alternator Voltage V28
Charging Alternator Capacity A35
Starting Voltage V24
Starting Motor Capacity kW9
Minimum Battery Capacity Ah2*200
Quantity of generator set's Bearing  (( For 400-660VAC generator ) 1
Quantity of generator set's Bearing  (( For Above 3300VAC generator ) 2
Engine Dimension  
Length mm1950
Width mm1389
Height mm1162
Engine Dry Weight w/o Cooling Systemkg2350

For more products, please visit our showroom honnydg.en.made-in-china.com

600kw 750kVA Diesel Generator Set 10.5kv 11kv Medium Voltage
600kw 750kVA Diesel Generator Set 10.5kv 11kv Medium Voltage
600kw 750kVA Diesel Generator Set 10.5kv 11kv Medium Voltage
600kw 750kVA Diesel Generator Set 10.5kv 11kv Medium Voltage
600kw 750kVA Diesel Generator Set 10.5kv 11kv Medium Voltage
600kw 750kVA Diesel Generator Set 10.5kv 11kv Medium Voltage
600kw 750kVA Diesel Generator Set 10.5kv 11kv Medium Voltage
600kw 750kVA Diesel Generator Set 10.5kv 11kv Medium Voltage
600kw 750kVA Diesel Generator Set 10.5kv 11kv Medium Voltage
600kw 750kVA Diesel Generator Set 10.5kv 11kv Medium Voltage


600kw 750kVA Diesel Generator Set 10.5kv 11kv Medium Voltage
For more details, please visit our website honnydg.en.made-in-china.com