Handheld Partial Discharge Detector for High Voltage Electrical Equipment

China Handheld Partial Discharge Detector for High Voltage Electrical Equipment, Find details about China Lab Equipment, Analyzer from Handheld Partial Discharge Detector for High Voltage Electrical Equipment

Model NO.
SYNY-0017SC
Measurement Range UHF
0~60dbmv
Measurement Range Hftc
50PC~100nc
Ultrasonic Sensor
20~200(kHz)
Tev Sensor
5 ~ 100MHz
UHF Sensor
300~2000(MHz)
Origin
Shanghai, China
HS Code
9030339000
Model NO.
SYNY-0017SC
Measurement Range UHF
0~60dbmv
Measurement Range Hftc
50PC~100nc
Ultrasonic Sensor
20~200(kHz)
Tev Sensor
5 ~ 100MHz
UHF Sensor
300~2000(MHz)
Origin
Shanghai, China
HS Code
9030339000

Application

It is used to detect local discharge source in medium and high voltage (MV/HV) equipment. Non-invasive detection method is adopted to detect and locate partial discharge defects of high-voltage electrical equipment.Noninvasive partial discharge detection provides a quick and simple method for identifying potential insulation faults that may cause power off or personal injury.
Partial discharge emits energy in the following ways:
Electromagnetic energy: radio waves, light, heat
Sound energy: sound wave, ultrasonic wave
Gases: ozone, nitrogen oxides.

Features

1.Continuously detect UHF, TEV and ultrasonic signals to judge whether there is any partial discharge;
2.Display the variation tendency of the detected signal in a real-time manner to intuitively judge the development of the partial discharge signal;
3.Field data storage function;
4.Screen display: high-contrast 3.5"TFT color screen.
5.Data storage: 1000 groups of test data can be stored.
6.Working power supply: embedded 8.4V lithium battery for 8h's continuous operation.
7.Power supply: input 100-240VAC, output 8.4V/3A, charging time 3~4h.

Technical specification

1.Sensor configuration
Standard equipment: ultrasonic sensor (UA), ground wave sensor (TEV)
Optional: transformer special sensor network, GIS special UHF sensor, high voltage cable special sensor, can also be customized according to user requirements.

2.Detection principle: UA, TEV and UHF
3.Detection frequency band:
                   UA: 40~200KHz
                   TEV: 3~100MHz
                   UHF: 300~2000MHz.
4.Measurement range:
                   UA: -6~70dBuV
                  TEV: 0~60dBmV
                  UHF: 0~60dBmV
                  HFCT:50pC~100nC
5.Sensitivity: the minimum sensitivity is 10pC (specifically determined by the distance between the sensor and the discharge source).
6.Sensor:
                a) Ultrasonic sensor: 20~200(kHz);
                b) TEV (Transient Earth Voltage) sensor: 5 ~ 100MHz;
                c) UHF sensor: 300~2000(MHz), with directional reception characteristic.
7.Embedded ultrasonic sensor and TEV & UA integrated sensor: such components as transformer dedicated sensor, GIS dedicated sensor and cable dedicated sensor can be selected

Sensors detailed pictures

Handheld Partial Discharge Detector for High Voltage Electrical Equipment

Company Profile

Handheld Partial Discharge Detector for High Voltage Electrical Equipment

Certifications

Handheld Partial Discharge Detector for High Voltage Electrical Equipment

Packaging & Shipping

Handheld Partial Discharge Detector for High Voltage Electrical Equipment