400A Hall Effect Current Sensor Current Transformer Module C3t Current Transducer

China 400A Hall Effect Current Sensor Current Transformer Module C3t Current Transducer, Find details about China Current Sensor, Open Loop Hall Current Sensor from 400A Hall Effect Current Sensor Current Transformer Module C3t Current Transducer

Model NO.
C3T
IP Rating
IP65
Certification
ISO
Customized
Customized
Rated Output
@IP=±ipn
Usage
Hall Sensor
Zero Voltage
Hall Sensor
Power Consumption
+35+ Io Ma
Supply Voltage
+12~+32V
Galvanic Isolation
@ 50Hz, AC, 1min2.5
Courier
DHL, TNT, FedEx...
Trademark
HEYI
Transport Package
Green Plastic Film
Specification
CE, ISO, Rohs
Origin
Liushi, Yueqing, Zhejiang Province, China
HS Code
8542390000
Model NO.
C3T
IP Rating
IP65
Certification
ISO
Customized
Customized
Rated Output
@IP=±ipn
Usage
Hall Sensor
Zero Voltage
Hall Sensor
Power Consumption
+35+ Io Ma
Supply Voltage
+12~+32V
Galvanic Isolation
@ 50Hz, AC, 1min2.5
Courier
DHL, TNT, FedEx...
Trademark
HEYI
Transport Package
Green Plastic Film
Specification
CE, ISO, Rohs
Origin
Liushi, Yueqing, Zhejiang Province, China
HS Code
8542390000

C3T series dismountable hall effect current Sensor is an open loop device based on the measuring principle of the hall effect, with a galvanic isolation between primary and secondary circuit. It provides accurate electronic measurement of DC currents.

 

Type

C3T-

400A

C3T-

600A

C3T-

800A

C3T-

1000A

C3T-

2000A

 

Unit

Rated current(Ipn DC)

400

600

800

1000

2000

A

Measure range(Ip DC)

0-800

0-1200

0-1600

0-2000

0-3000

A

Rated output

@Ip=±Ipn                 ±2±1%

V

Zero voltage

@Ip=0                     5±0.5%

V

Supply voltage

+12

V

Power Consumption

≤15

mA

Zero offset voltage

@Ip=0                       ±20

mV

Magnetic offset

@Ip=±Ipn-0                  ±15

mV

Offset drift

@ -40~+85ºC               ≤±0.5

mV/ºC

Output drift

@ -40~+85ºC               ≤±0.5

mV/ºC

Linearity

@Ip=0-±Ipn                  ≤1

%FS

Response time

@50A/μS, 10%-90%          ≤7

μs

Galvanic isolation

@ 50HZ,AC,1min              2.5

KV

 

 

Applications

Variable speed drives

Welding machine

Battery supplied applications

Uninterruptible Power Supplies (UPS)

Electrochemical

 Mechanical dimension (for reference only) 

 

 

 

Remarks:

1. All dimensions are in mm.

2. General tolerance ±1mm

3. Elucidation:  1:+12V  2: 0V  3:V0UT  4:0V

Directions for use

 

1. When the current will be measured goes through a Sensor, the voltage will be measured at the output end.(Note: The false wiring may result in the damage of the Sensor)

2. The output amplitude of the Sensor can be adjusted according to users' requirements.

3. Custom design in the different rated input current and the output voltage are Sensor.

 

Standards

 

·UL94-V0.

·EN60947-1:2004

·IEC60950-1:2001

·EN50178:1998

·SJ 20790-2000

 

General date

 

 

Value

Unit

Operating temperature (TA)

-40 to +85

 

Storage temperature (TS)

-40 to +125

 

Mass(approx) (M)

       300

g