Hall Effect Current Sensor DC Clamp on Current Sensor

China Hall Effect Current Sensor DC Clamp on Current Sensor, Find details about China Hall Sensor, Clamp on Current Sensor from Hall Effect Current Sensor DC Clamp on Current Sensor

Model NO.
D-C1T
IP Rating
IP65
Certification
ISO
Customized
Customized
Output
Analog Sensor
Usage
Hall Sensor
Theory
Hall Sensor
Supply Voltage
+12V,+15V,+24V
Power Consumption
<25
Galvanic Isolation
@ 50Hz,AC,1min 2.5
Trademark
HEYI
Transport Package
Export and Air-Worthy Standard Carton
Specification
IEC 6044-1
Origin
Yueqing China
HS Code
8542390000
Model NO.
D-C1T
IP Rating
IP65
Certification
ISO
Customized
Customized
Output
Analog Sensor
Usage
Hall Sensor
Theory
Hall Sensor
Supply Voltage
+12V,+15V,+24V
Power Consumption
<25
Galvanic Isolation
@ 50Hz,AC,1min 2.5
Trademark
HEYI
Transport Package
Export and Air-Worthy Standard Carton
Specification
IEC 6044-1
Origin
Yueqing China
HS Code
8542390000
D-C1T series hall effect current Sensor is an open loop device based on the measuring principle of the hall effect, with a galvanic isolation between primary and secondary circuit. It provides accurate electronic measurement of DC currents.
Electrical data (Ta=25ºC±5ºC)
 
TypeD-C1T-
100A
D-C1T-
200A
D-C1T-
300A
D-C1T-
400A
D-C1T-
500A
Unit
Rated current(Ipn DC)100200300400500A
Measure range(Ip DC)0-1500-3000-4500-6000-750A
Rated output@Ip=±Ipn DC 4V
Supply voltage+12V,+15V,+24VV
Power Consumption<25mA
Offset voltage@Ip=0 ±20mV
Magnetic offset@Ip=±Ipn-0 ±20mV
Offset drift@ -40~+85ºC ≤±1mV/ºC
Output drift@ -40~+85ºC ≤±1mV/ºC
Linearity@Ip=0-±Ipn ≤1%FS
Response time@50A/μS, 10%-90% ≤7μs
Galvanic isolation@ 50HZ,AC,1min 2.5KV


 
Applications

·Variable speed drives
·Welding machine
·Battery supplied applications
·Uninterruptible Power Supplies (UPS)
·Electrochemical

Remarks:
1. All dimensions are in mm.
2. General tolerance ±1mm.
3. Elucidation: 1:+12V 2: 0V 3:V0UT 4:0V
 
Directions for use
1. When the current will be measured goes through a Sensor, the voltage will be measured at the output end.(Note: The false wiring may result in the damage of the Sensor)
2. The output amplitude of the Sensor can be adjusted according to users&#8217; requirements.
3. Custom design in the different rated input current and the output voltage are Sensor.
 
Standards

·UL94-V0.
·EN60947-1:2004
·IEC60950-1:2001
·EN50178:1998
·SJ 20790-2000
 
General date
 
 ValueUnit
Operating temperature(TA)-40 to +85ºC
Storage temperature(TS)-40 to +125ºC
Mass(approx) (M)65g