China Hall-Effect Current Sensor (K5X) Current Transducer, Find details about China Current Sensor, Open Loop Hall Current Sensor from Hall-Effect Current Sensor (K5X) Current Transducer
The magnetic flux created by the primary current IP is balanced by a complementary flux produced by driving a current through the secondary windings. A hall device and associated electronic circuit are used to generated the secondary (compensating) current that is an extract representation of the primary current.
Type | K5X-200A | K5X-500A | K5X-1000A | K5X-1500A | |
Primary nominal input current | 200 | 500 | 1000 | 1500 | A |
Measuring range of primary current | 0- ± 400 | 0- ± 1000 | 0- ± 2000 | 0- ± 2500 | A |
Secondary nominal output voltage | 4± 1% | V | |||
Supply voltage | ± 12- - ± 15 | V | |||
Current consumption | 20+Is | mA | |||
Insulation voltage | 6KV/50Hz/1min | ||||
Linearity | 1 | %FS | |||
Zero offset voltage | (TA=25C) ± 25 | mV | |||
Residual voltage | ± 30 | mV | |||
Thermal drift of V0 | ± 1 | mV/C | |||
Response time | 7 | μ s | |||
Frequency bandwidth(-3dB) | DC- - 20 | KHz | |||
Ambient operating temperature | -40- - +85 | C | |||
Ambient storage temperature | -40- - +125 | C | |||
Load resistance | (TA=25C) ≥ 10K | Ω |