China 15V 12A LED Mini Switching Power Supply, Find details about China Mini Switching Power Supply, Switching Power Supply from 15V 12A LED Mini Switching Power Supply
Model /Specification | S-25-5 | S-25-12 | S-25-15 | S-25-24 | ||
DC output voltage | 5V | 7.5V | 12V | 24V | ||
Output voltage error (Note2) | ± 2% | ± 1% | ± 1% | ± 1% | ||
Rated output current | 5A | 18A | 12A | 6A | ||
Output current rage | 0-5A | 0-2.1A | 0-1.7A | 0-1.1A | ||
Wave and noise(Note3) | 50mVp-p | 100mVp-p | 100mVp-p | 100mVp-p | ||
Inlet stability(Note4) | ± 0.5% | ± 0.5% | ± 0.3% | ± 0.2% | ||
Load stability(Note5) | ± 1% | ± 0.5% | ± 0.3% | ± 0.2% | ||
DC output power | 25W | 25.2W | 25.5W | 26.4W | ||
Efficiency | 72%/115VAC | 76%/115VAC | 77%/115VAC | 80%/115VAC | ||
Adjustable range for DC voltage | +10, -5% | ± 10% | ± 10% | ± 10% | ||
AC input voltage range | 85~264VAC/47~63VAC; 120~370VDC | |||||
Input current | 0.6A/115V 0.35A/230V | |||||
AC impulse current | Cold-start current 15A/115V 30A/230V | |||||
Leakage current | < 0.75mA/240VAC | |||||
Overload protection | 105%~150% Type: PULSING HICCUP SHUTDOWN; Reset; auto recovery | |||||
Over-voltage protection | 115%~135% | |||||
High-temperature protection | ^ ^ | |||||
Temperature coefficient | ± 0.03% degrees Celsius (0~50 degrees Celsius) | |||||
Setup rise hold up time | 800ms, 50ms, 20ms/115VAC 300ms, 50ms, 80ms/230VAC | |||||
Vibration | 10~500Hz, 2G 10min. /1cycle, Period for 60min, Each axes | |||||
Withstand voltage | Input and output interval: 3KVAC, Input and enclosure: 1.5KVAC, Output and enclosure: 0.5KVAC | |||||
Isolation resistance | Input and output interval, Input and enclosure, Output and enclosure: 0500VAC/100M Ohms | |||||
Working temperature and humidity | -10 degrees Celsius~+60 degrees Celsius, 20%~90%RH | |||||
Store temperature and humidity | -20 degrees Celsius~+85 degrees Celsius, 10%~95RH | |||||
Overall dimension | 99*97*35mm | |||||
Weight | 0.37Kgs | |||||
Safety standards | Meet UL1012, TUV EN60950 | |||||
EMC standards | Meet IEC801-2, 3, 4, IEC555-2 | |||||
Note: 1. The testing condition for the parameter above is: 230VAC input, rated load, 25 degrees Celsius 70%Rh, Humidity 2. Error, include the setting error, line stability and load stability. (Note: 5) 3. Wave test: adopting" A12" double wire for 20MHz, and 0.1uF& uF capacitor short-circuit for interrupting 4. Inlet voltage stability test: when is over load, the lowest voltage of inlet is representative to the highest voltage. 5. Load stability test: The load is from 0% to 100%, others 60%. 6. C2, 3, 11must be knocked down. |