China High Wear Resistance Carbon Fiber / Glass Fiber / Resin / HDPE Doctor Blade, Find details about China Scrape Blade, Cleaning Blade from High Wear Resistance Carbon Fiber / Glass Fiber / Resin / HDPE Doctor Blade
Once in the maintenance period, the doctor blade is usually easily ignored. But some simple routine maintenance can keep the equipment running efficiently.One of the most effective ways to check the same problem is to check the blade with vision. The following table shows the different types of blade wear and the corresponding treatment methods. This inspection method is very effective.
Problem | Reason | Measure |
Uneven wear, frequent blade replacement | 1. The surface of roller or dryer is uneven 2. The doctor holder is damaged or dirty 3. Sediment | 1. Use a softer blade 2. Clean, repair or replace the doctor holder 3. Use abrasive blade |
Excessive wear on middle or edge of blade | 1. The blade is not installed on the top of the roller 2. The old blade sinks (or leaves) the roller or dryer | 1. Refit or add gasket at the back of blade if necessary 2. Replace the old and sunken blade |
Excessive wear at one end of blade | The displacement of blade is not parallel to the axial direction of roller or dryer | Add gasket, if necessary, move bearing and bracket to adjust scraper parallel to axial direction |
The blade is worn evenly, but the end face is rough | 1. There is deposit on the surface of roller or dryer 2. The pressure of blade is too high 3. The material of blade is too hard | 1. Use abrasive blade when necessary 2. Reduce the pressure 3. Use a slightly soft blade |
Excessive wear in sheet area | The sheet leaves sediment on the roller or dryer | 1. Use abrasive blade when necessary 2. Trim the edge of blade frequently 3. Use blade with slotted end to prevent excessive pressure on both ends of roller or dryer |
Excessive wear out of sheet area | The sheet lubricates the roller or dryer | Use blade with slotted end |
Local depression | The blade is damaged, electrostatic (discharge/ electrolysis /heating) | Insulate the blade from the holder or use a non-metallic blade |
The blade produces burr | 1.The material of the blade is too soft 2. The pressure is too high 3. The angle of the blade is too small | 1. Use a slightly hard scraper 2. Reduce the pressure 3. Adjust the bearing or bracket to increase the angle, and use the instrument to check and correct the angle |
Carbon Fiber 20 Doctor Blade | Carbon Fiber 40 Doctor Blade | ||
Product Name | SH-2C--Carbon fiber blade | Product Name | SH-4C--Carbon fiber blade |
Material : | Composed of 20% Carbon fiber and glass fiber. | Material | Carton fiber 40%. Epo-glass fiber, with better lubricity and anti-abrasion. |
Application: | Suitable for chrome rolls, dryer cylinder,stone rolls, rubber rolls. | Application: | Suitable for dryer cylinder, chrome rolls,stone rolls, rubber rolls. |
Temperature resistance: | 185°C | Temperature resistance: | 185°C |
Bending strength: | 600N/mm2. | Bending strength: | 760N/mm2. |
Blade thickness | 1.5mm or 2mm | Blade thickness | 1.5mm or 2mm |
Blade width | 75-76mm | Blade width | 75-76mm |
Blade Length | customized | Blade Length | customized |
1.Bubble Film and waste thick fabric wrapping while protecting inside fabric.
2.Wrapped special fabric package outside(Air shipping).
3.Composite wooden box(sea shipping).
SUN HONG as a professional manufacturer of all kinds of soft packaging and printing paper making doctor blade.
We own professional technical staff, which provide you a full range of solutions in packaging and printing industry related technology equipment for customers.
Our company will stick on good faith principle, pragmatic attitude, to provide high-quality products and service for the domestic printing industry.