China Ammonia NH3 Gas Detector Sensor Leak Detection 1000 ppm Toxic Gas Safety Monitoring Electrochemical Standard, Find details about China Membrapor, Ammonia Sensor from Ammonia NH3 Gas Detector Sensor Leak Detection 1000 ppm Toxic Gas Safety Monitoring Electrochemical Standard
Nominal Range | 0 - 1000 ppm |
Maximum Overload | 2000 ppm |
Expected Operation Life | 2 years in air |
Output Signal with | 25 ± 8 nA/ppm |
Resolution | 4 ppm |
Temperature Range | - 10 °C to 40 °C |
Pressure Range | Atmospheric 1) |
Pressure Coefficient | No data |
T90 Response Time with | < 35 sec |
Relative Humidity Range | 15 % to 90 % R.H. non-condensing |
Typical Baseline Range (pure air, 20°C) | 0 ppm to ± 16 ppm |
Maximum Zero Shift (+20°C to +40°C) | -32 ppm |
Long Term Output Drift | < 5% per 6 months |
Recommended Load Resistor | 10 Ohm |
Bias Voltage | Not allowed |
Repeatability | < 3 % of signal |
Output Linearity | < 5 % full scale |
Humidity Effect 2) | < 16 ppm |
Weight | ~32 g |
Position Sensitivity | None |
Storage Life | Six months in container |
Recommended Storage Temperature | 5 °C - 20 °C |
Warranty Period | 12 months from date of dispatch |
Interfering Gas | Concentration (ppm) | Reading (ppm) |
CO | 300 | 0 |
H2 | 200 | 0 |
SO2 3) | 20 | -7 |
H2S 3) | 20 | 7 |
NO 3) | 20 | -1 |
NO2 3) | 20 | -20 |
Cl2 | 20 | -55 |
CO2 | 2% | 0 |
SiH4 | 10 | 0 |
Module type | GM-I2(3)-M/C/S-**-****/G/P/F/FL |
Detected gas | Toxic gas |
Detecting principle | Electrochemistry |
Sampling | Diffusing pump flange thread |
Responding time | 30s~40s(of the sensor) |
Module accuracy | ≤±3%FS(actual concentration, higher accuracy depends on specified sensors) |
Module repeatability | ≤±2% FS |
Module linear error | ≤±2% FS |
Module zero temperature drift | ≤±2% (FS/year) |
Module operating temperature | -40~80°C |
Module humidity | 0-95%RH(non-condensation) |
Sensor operating temperature | -20°C~50°C |
Sensor humidity | 0-90%RH(non-condensation) |
Signal output | TTL/4-20mA /RS485 (two or three wire) |
Transmitting distance | 1000 meters(RS485) |
Operating voltage | DC 12-36V |
Maximum power | ≤0.8W |
Size | 80*48mm |
Explosion proof | Intrinsic safe |
Connection cable | RVVP3 x 1.5mm² |