China Alcohol Alc Gas Sensor Detector Methanol Measurement Eletrochemical Toxic Miniature, Find details about China Membrapor, Alcohol Sensor from Alcohol Alc Gas Sensor Detector Methanol Measurement Eletrochemical Toxic Miniature
Detecting range (ppm) | Output Signal (nA/ppm) | Features |
Alc/M-200 | 1000.00 ± 250.00 | Methanol / Ethanol Measurement |
Nominal Range | 0 - 200 ppm |
Maximum Overload | 400 ppm |
Expected Operation Life | 2 years in air |
Output Signal with Ethanol Methanol | 1'000 ± 400 nA/ppm 1'100 ± 400 nA/ppm |
Resolution | 0.2 ppm |
Temperature Range | - 20 °C to 50 °C |
Pressure Range | Atmospheric±10% |
Pressure Coefficient | No data |
T90 Response Time with Ethanol Methanol | < 25 sec < 200 sec |
Relative Humidity Range | 15 % to 90 % R.H. non-condensing |
Typical Baseline Range (pure air, 20°C) | 0.5 to 2.5 ppm equivalent |
Maximum Zero Shift (+20°C to +40°C) | N.D. |
Long Term Output Drift | < 2% signal loss/month |
Recommended Load Resistor | 10 Ohm |
Bias Voltage | + 300 mV |
Repeatability | < 2 % of signal |
Output Linearity | Linear |
Weight | ~ 5.4 g |
Position Sensitivity | None |
Storage Life | Six months in container |
Recommended Storage Temperature | 5 °C - 20 °C |
Warranty Period | 12 months from date of dispatch |
Interfering Gas | Concentration | Reading |
CO | 100 ppm | <1 ppm |
Interference from unsaturated hydrocarbons |
Module type | GM-I2(3)-M/C/S-**-****/G/P/F/FL |
Detected gas | Toxic gas |
Detecting principle | Electrochemistry |
Sampling | Diffusing pump flange thread |
Responding time | 30s~40s(of the sensor) |
Module accuracy | ≤±3%FS(actual concentration, higher accuracy depends on specified sensors) |
Module repeatability | ≤±2% FS |
Module linear error | ≤±2% FS |
Module zero temperature drift | ≤±2% (FS/year) |
Module operating temperature | -40~80°C |
Module humidity | 0-95%RH(non-condensation) |
Sensor operating temperature | -20°C~50°C |
Sensor humidity | 0-90%RH(non-condensation) |
Signal output | TTL/4-20mA /RS485 (two or three wire) |
Transmitting distance | 1000 meters(RS485) |
Operating voltage | DC 12-36V |
Maximum power | ≤0.8W |
Size | 80*48mm |
Explosion proof | Intrinsic safe |
Connection cable | RVVP3 x 1.5mm² |