24V Photoelectric Smoke Detector Cigarette Sensor in Conventional Fire Alarm System

China 24V Photoelectric Smoke Detector Cigarette Sensor in Conventional Fire Alarm System, Find details about China Conventional Fire Alarm Smoke Detector, Smoke Detector from 24V Photoelectric Smoke Detector Cigarette Sensor in Conventional Fire Alarm System

Model NO.
AW-CSD381
Infrared Sensor Probe Type
Infrared Temperature Sensor
Infrared Sensor Installation
Ceiling
Height
48.2mm Installed in Base
Smoke Alarm Sensitivity
0.1-0.15dB/M
Operating Temperature Range
-10ºC to 50ºC(14ºF to 122ºF)
Operating Voltage Range
9 to 28 VDC Non-Polarized
Standby Current
≤120ua @ 24VDC
Standard Number Ref
En 54-7:2000
Ec Certificate
0832-CPR-F2071
Trademark
ASENWARE
Transport Package
Carton Packing
Specification
99.45mm
Origin
China
Model NO.
AW-CSD381
Infrared Sensor Probe Type
Infrared Temperature Sensor
Infrared Sensor Installation
Ceiling
Height
48.2mm Installed in Base
Smoke Alarm Sensitivity
0.1-0.15dB/M
Operating Temperature Range
-10ºC to 50ºC(14ºF to 122ºF)
Operating Voltage Range
9 to 28 VDC Non-Polarized
Standby Current
≤120ua @ 24VDC
Standard Number Ref
En 54-7:2000
Ec Certificate
0832-CPR-F2071
Trademark
ASENWARE
Transport Package
Carton Packing
Specification
99.45mm
Origin
China
LPCB EN54 APPROVED CONVENTIONAL SMOKE DETECTOR  

AW-CSD381



24V Photoelectric Smoke Detector Cigarette Sensor in Conventional Fire Alarm System
AW-CSD381 is conventional photo-electronic smoke detector uses a state of-the-art optical sensing chamber.
This detector is designed to provide open area protection and to be used with most conventional fire alarm panel.


The conventional rate of rise of rise heat detector uses thermal component to detect the temperature changing in the
environment. It can enable fire alam when the temperature difference achieved the setting rate of rise temperature
value reach the setting fixed ualue. It has a stable and reliable working performance.


Two LEDs on each detector provide local 360° visible alarm indication. They flash every six seconds indicating that power 
is applied and the detector is working properly. The LEDs latch on in alarm. LEDs will be off when a trouble condition exists
indicating that the detector sensitivity is outside the listed limit. The alarm can be reset only by a momentary power interruption.


The detector that initiated the alarm condition will have its red LED and relays latched until reset by panel.



FEATURES
 
Operating Voltage Range9 to 28 VDC Non-polarized
Standby Current≤120uA@24VDC
Maximum Alarm Current (LED on)≤15mA@24VDC
(1K Ohm current-limiting resistance)
Operating Humidity Range≤95%RH(40ºC±2ºC)RelativeHumidity,Non-condensing 
Operating Temperature Range-10ºC to 50ºC(14ºF to 122ºF)
Smoke Alarm Sensitivity0.1-0.15dB/m
Height48.2mm installed in Base
Diameter99.45mm
Standard Number refEN 54-7:2000
EC certificate0832-CPR-F2071


PARAMETER

24V Photoelectric Smoke Detector Cigarette Sensor in Conventional Fire Alarm System

COMPANY

Asenware, manufacturer of fire alarm and fire suppression system since 2005. Our headquarter is in London, UK, with
factory Shenzhen, China.
We keep our best service for our customers,and have a rich experienced engineer team to design and install for overseas project.

Product range:

Addressable fire alarm system
Conventional fire alarm system (2166 series)
FM200 gas suppression system (2159 series)
Fire pump
Fire hose/hose reel and cabinet
Abc powder/co2 fire extinguisher
Emergency light system


24V Photoelectric Smoke Detector Cigarette Sensor in Conventional Fire Alarm System



CERTIFICATES

24V Photoelectric Smoke Detector Cigarette Sensor in Conventional Fire Alarm System


SERVICE

Ø OEM & ODM service: YES
Ø Technical support and After-sale service: YES
Ø Warranty: 1 YEAR
Ø Delivery Time: 3 - 5 days after payment received
Ø Shipping: delivery by air, ship or DHL, FEDX etc. Express for your order

CONTACT US

Rella Liang