Building Material Polypropylene Fibre Fiber Cement

China Building Material Polypropylene Fibre Fiber Cement, Find details about China Blended Fiber, Synthetic Fiber from Building Material Polypropylene Fibre Fiber Cement

Model NO.
ELE-PMFT
Length
48mm, 54mm or as Per Request
Melting Point(C Deg. )
160-170
Certificate
ISO and Ce
Elastic Modulas
3500 Min
Crack Elongation
20+/-5%
Strength Grade(MPa)
450 Min.
Trademark
ELITE-INDUS
Transport Package
5.5 Ton/20 Gp, 12ton/40 Hq
Specification
0.5/1 KG per PE or paper bag, 10 Kg/Nonwoven bag
Origin
Anhui
HS Code
55034000
Model NO.
ELE-PMFT
Length
48mm, 54mm or as Per Request
Melting Point(C Deg. )
160-170
Certificate
ISO and Ce
Elastic Modulas
3500 Min
Crack Elongation
20+/-5%
Strength Grade(MPa)
450 Min.
Trademark
ELITE-INDUS
Transport Package
5.5 Ton/20 Gp, 12ton/40 Hq
Specification
0.5/1 KG per PE or paper bag, 10 Kg/Nonwoven bag
Origin
Anhui
HS Code
55034000

Building Material Polypropylene Fibre Fiber Cement

Product Description:
ELITE Reinforcing Macro Synthetic Fiber Hybrid/ Blended is the mixturer of twisted fiber and fibrillated fiber, can be used to instead of steel fiber for reinforcement to cement concrete. Compared with steel fiber, it has the advantage of easy dispersing and blending, no damage to the mixing equipment, etc
     
Our Fiber have rough surface Treatment by special parallel thread extruding & twisting process. It has high break strength, better dispersion and strong combining ability, will be widely used to instead of steel fibre to reinforce the cement concrete and crack resistant.

Building Material Polypropylene Fibre Fiber Cement


1, Our fiber are made by Virgin copolymer;
2, We make the yarn by ourselves. We always have stock and make delivery in 3-7 days;
3, Capacity 600Ton/Month, 7000Ton/Year Production;
4, 70% Export to : Ecuador, Australia, Singapore, Malaysia, Vietnam, Turkey, Iran, France, Sri Lanka, Colombia...

Compliance: BS EN 14889 - 2

Brief specification:
 
Density(g/cm3)0.91 +/- 0.01Raw materialcopolymer
Length(mm)48mm,54mm or as per requestEquivalent Dia(mm)0.3±0.03
Shapetwistbreak tensile Ratio(%)8-15
ColourWhite or BrownMelting point ( C. Deg)160-170
Tensile Strength>480 MPaWater absorbencyNO
Elastic Modulus (mPa)>3500Resistance to acid & alkalistrong


Packing: 
PP Fiber ShapeInner Packing
(PE film bag)
Outer Packing
(Plastic Woven bag)
20'gp40'HQ
hybrid0.5/1.0 kg10kg5500kg12000kg
 Inner Packing
 (water Soluble paper bag)
Outer Packing 
(Carton)
20' Gp40' HQ
hybrid0.5/1.0 kg10kg4000kg9000kg
Building Material Polypropylene Fibre Fiber Cement

Advantages:
Compared with steel fiber, our fiber Twist has the advantages of corrosion and wear-resistant reducing 50% cost with same volume to steel fiber.
1. Decrease the fragility of high strength concrete;
2. Increase the quality of concrete;
3. Increase the freezing resistance of concrete;
4. Increase the impact resistance of concrete;
5. Increase the durability resistance of cncrete;
6. Increase the fire resistance of concrete.

Applying Instruction:
1, Ration design of the fibre concrete:
 Generally the recommended amount to add to the concrete is more than 2.7kg per sqm ( volume ratio is 0.3% ), reinforcement adding amount is 5.5kg, Compared with adding 47kg of steel fibre, 5.4kg polymer  fibre has the same volume ratio to  the concrete.

2, Matching Ratio:
Usually, it is no need to Change the matching ratio of the concrete. Considering the requirement of fissure-resistant, the polymer fiber is recommend to combine with the polypropylene fiber mesh with the volume ratio of 1:1 ( 0.9kg fiber-mesh per sqm of cement concrete).
 
4, Mixer Adoption: Double-axle horizontal compelling mixer is priority.
 
5, Mixing process:
Crushed stones, fibers and sands are put into the mixer in succession. After stirring for two minutes,fiber will fully spread and then add cement and water and stir normally. The addition of materials also can be put into as common concrete, but the stirring time should be properly prolonged to make fiber completely Mixed.
 
6, Shaping & Maintenance
There is no special requirement, may along the vibrating time for 30s, The maintenance of the fibre concrete
should be  done same as the normal concrete.

Applications:
Building Material Polypropylene Fibre Fiber Cement


A). Projects like concrete road, bridge, airport road and factory floor which strictly require cracking resistance. The life span of these projects will be lengthened for 5-10 years.
B). The walls of tunnels, mines, roofs and reservoir projects with special construction. When using spray technology in concrete construction, the polypropylene fiber added into the concrete can effectively decrease the spray concrete's deformation rate of the walls less than 8% and that of the roof less than 12%, and also can reduce the friction. It can
improve the constructing efficiency and working environment and popularize the spray technology.
C). River courses and dams, etc. The polypropylene fiber can improve concrete's resistance to crack and squirt and wear to lengthen projects' life span.
D). Military defense works, dock banks and piers, etc. This fiber can greatly strengthen the concrete's spurt resistance and heighten these projects' safety and lengthen their life span.

Our Company:
Building Material Polypropylene Fibre Fiber Cement
Building Material Polypropylene Fibre Fiber Cement



ELITE was established in 2007, has become one of the leading and professional suppliers of many kinds of Concrete Reinforcement Fibers in the world market.

ELITE fibers are made by 100% virgin materials with advanced equipment of yarn and cutting. We have one full set of precise testing instrument and quality inspection team, technology research & Development team.

Elite own a team with 10+ years experience.We know well of Chinese Concrete reinforcement fibers   on technical inspection, marketing, transportation.

Pls feel free to contact us freely at any time
Ms. Helen Chu