High Quality L-CNG Filling System Station Product Description: Number | Project | Parameter |
1 | Type | Horizontal /Piston |
2 | The number of columns | 1 or 2 |
3 | Design temperature | -196ÂșC |
4 | Medium | LNG |
5 | Max inlet pressure | 1.6MPa |
6 | Min inlet pressure | 0.02MPa |
7 | Max outlet pressure | 25MPa |
8 | Design pressure | 27.5MPa |
9 | Floe rate | 1500L/h(liquid) or 2000L/h(liquid) |
10 | Motor power | 22KW or 39KW |
11 | Uptime | Continuous orIntermittent |
Characteristics of L-CNG refueling station:
1. LNG can be transported by Tankers, instead of natural gas pipelines.
2. Energy-saving. The traditional CNG fueling station cost 3~15 times energy than LNG station.
3. Equipments investment saving. The LNG storage tank has a high density capacity to achieve less land use and high safety level.
4. The high-pressure vaporizer applies to a wide arrange of working temperature. Its main-body is specially designed to reach a high efficiency heat exchange and it is also running much stable and at a low running cost.
5. The LNG liquid can be gasified directly and rapidly. The capacity is big enough for 10 vehicles fueling at the same time.
6. The equipment installation location is flexible, and LNG storage capacity can be adjusted according to clients need.
7. The equipment is small size but high efficience, small land occupation, small investment volume, and short construction period.