Pct High Pressure Accelerated Aging Test Machine Semi Conductor Reliability Test Chamber

China Pct High Pressure Accelerated Aging Test Machine Semi Conductor Reliability Test Chamber, Find details about China Highly Accelerated Weathering Test, Hast Test Chamber from Pct High Pressure Accelerated Aging Test Machine Semi Conductor Reliability Test Chamber

Model NO.
HAST-55
Device Cooling Method
Natural Cooling or Air Purging Type
Temp. Range
105c~135c(at 100% Relative Humidity)
Humidity Range
Std Saturation Test Mode: 100%Rh
Pressure Range
Gauge Pressure: +0.2 ~ 200kpa
Standards Complied
IEC-60068-2-66
Inside Material
SUS316 Stainless Steel Plate
Trademark
KOMEG
Transport Package
by Plywood Case
Specification
Ø 550 mm*D650mm
Origin
China
HS Code
90321000
Model NO.
HAST-55
Device Cooling Method
Natural Cooling or Air Purging Type
Temp. Range
105c~135c(at 100% Relative Humidity)
Humidity Range
Std Saturation Test Mode: 100%Rh
Pressure Range
Gauge Pressure: +0.2 ~ 200kpa
Standards Complied
IEC-60068-2-66
Inside Material
SUS316 Stainless Steel Plate
Trademark
KOMEG
Transport Package
by Plywood Case
Specification
Ø 550 mm*D650mm
Origin
China
HS Code
90321000

PCT High Pressure Accelerated Aging Test Machine Semi conductor reliability Test Chamber

Product description

The PCT high-pressure accelerated aging test is mainly to test moisture resistance of the semiconductor package. The product to be tested is placed in a specific temperature, humidity and pressure environment to test the pressure resistance and air tightness of the sample. If the semiconductor package not good condition, the moisture will follow the glue or the glue and the wire. The interface of the rack penetrates into the package. The common causes of failure include popcorn effect, open circuit caused by corrosion in the metalized area, and short circuit between the pins of the package due to pollution.

Volume and dimension

VolumeAbout 55L
Interior sizeØ550 mm*D650mm(Drum type pressure inner box)
  Exterior sizeW900 mm*H1552mm*D1500 mm(Excluding the protruding part of the machine!)
Tips: For external dimensions, please confirm the three views according to the final design!

The main technical parameters

 Test ConditionsCool method: :Natural cooling or air purging
Measured at a room temperature of +25 ºC under no load, Measured at normal pressure 101.3Kpa, the temperature and humidity performance test is measured according to the relevant regulations according to GB/T 2424.5 or IEC60068 -3; the sensor is placed at the air outlet of the air handling unit.
 Temperature range+105ºC~+135ºC(At 100% relative humidity)
Temp.  fluctuation±0.5ºC
Temp. uniformity≤±3.0ºC
Temp. deviation≤±3.0ºC
  Humidity range1) HUM unsaturated test mode: 65~100%RH
2) STD saturation test mode: 100%RH
 Humidity Fluctuation ±3.0%RH
 Humidity Deviation±5.0%RH
 Temperature change rateHeat up rate:
 +25ºC~+135ºC, full range average speed  approx 45 min (no-load,no heating)
Loadno
 Note:Measured at a room temperature of +25 ºC under no load,the temperature and humidity performance test is measured according to the relevant regulations according to GB/T 2424.5 or IEC60068 -3; the sensor is placed at the air outlet of the air handling unit.
  Pressure rangeGauge pressure: +0.2 ~ 200Kpa
*Absolute pressure: 100 ~ 300Kpa
  Pressure deviation≤±2 kPa
  Pressure rise timeAtmospheric pressure to 200Kpa   20min


Product technical features

·Using wet and dry bulb sensor for direct measurement

The control modes are divided into three modes: dry and wet bulb, unsaturated and wet saturated.

·Double-layer cylinder structure, multiple protection functions

The inner tank adopts a circular arc design to prevent condensation and dripping water, which meets the national safety container regulations. Multiple man-machine protections such as various over-pressure and over-temperature, dry-burning leakage and misoperation.

·Slow pressure reduction treatment, optional exhaust and drainage mode

Prevent the sample from being affected by sudden pressure, temperature or water evaporation after the test.

·Automatic water replenishment function, front water level confirmation

At the beginning of the test, the system will automatically add enough water for the test at one time, and the remaining water in the tank can be simply confirmed from the front.

·Komeg independently researched and developed control system, intelligent setting, easy operation

It adopts 7-inch true color touch screen, has 250 groups of 12,500 programs, has USB curve data download function, and RS-485 communication interface.
Pct High Pressure Accelerated Aging Test Machine Semi Conductor Reliability Test Chamber
Pct High Pressure Accelerated Aging Test Machine Semi Conductor Reliability Test ChamberPct High Pressure Accelerated Aging Test Machine Semi Conductor Reliability Test ChamberPct High Pressure Accelerated Aging Test Machine Semi Conductor Reliability Test ChamberPct High Pressure Accelerated Aging Test Machine Semi Conductor Reliability Test Chamber

PCT high pressure accelerated aging test conditions

Test equipment: KOMEG brand PCT pressure cooker testing chamber

Temperature range: +105ºC to +162.5ºC, humidity range: 100%R.H