China Gas Chromatography Analysis Transformer Oil Dissolved Gas Analyzer, Find details about China Dissolved Gas Analyzer, Gas Chromatograph from Gas Chromatography Analysis Transformer Oil Dissolved Gas Analyzer
Self-diagnostic function:
1) Core tests;
2) Automatic tests;
3) Extended tests;
4) Basic tests;
Monitor the status of GC continuously. Once finding faults, it'll display the information and show the wrong zone and the settling method.
Self-protective function:
1) Overrun temperature protection;
2) Short circuit hint;
3) TCD filament protection;
4) FID flameout hint;
5) PFD exposed-light protection;
6) Keyboard locking with password; etc., ensuring normal running.
Simple operation, powerful automation:
1) All parameters can be entered through keyboard with prompt function;
2) 4 sets of complete chromatography analysis methods can be stored and recalled automatically;
3) An autosampler can be connected;
4) Parameters can be modified instantly while the GC is running;
5) Chromatography analysis method can be activated for 99 times repeatedly at the same time. It's especially suitable for unattended operation.
More choices of injectors:
1) On- Column Injector for Packed Column;
2) Flash Vaporization Injector for Packed Column
3) Automatic or manual gas inject valve;
4) Headspace sampler;
5) Thermal desorption system
6) Split/Splitless Capillary Injector; Three Injectors or two Split/Splitless Capillary Injectors can be fixed on GC.
More choices of detectors:
1) TCD; 2) FID; 3) ECD; 4) FPD; 5) TSD
Maximum of two TCDs or three different kinds of detectors can be installed.
Reactor: 1) Internal; 2) external
Time programming of detectors:
Each of detectors has 5-ramp programmable time control. Output-signal, attenuation range, and polarity can be set automatically.
Time programming of external events:
Providing 4 external events with 20-ramp programmable time control. The optional GC relays may be used to automate valves, operate split/splitless capillary injectors, drive auxiliary devices, or switch signals between detector A and detector B in a run.
Many kind of special-purpose GC can be provided according to user's request.
Specifications:
Column oven:
Operating temperature range: ambient temperature to 400ºC;
Dual opening-door at the back of column oven;
Cooling time: 250ºC to 50ºC in 5 min;
Programmable oven with 4-ramp temperature control;
Temperature programming rate: 0.1~50ºC/min
Injector system:
Operating temperature range: ambient temperature to 400ºC
Thermal conductivity detector -TCD:
Maximum temperature: 400ºC
Sensitivity: ≥10000mv • mL/mg (for butane)
Linear range: 105
Current range: 50 to 400mA
Filament protection:
If He or H2 carrier gas flow in the detector cell is cut off for 4 minutes, filament power will be shut off automatically.
Flame ionization detector-FID:
Maximum temperature: 400ºC
Minimum detectivity: ≤5×10-12g/s (n-C16)
Linear range: 107
Flameout hint: monitoring the status of GC continuously after being turned on.
Electron capture detector-ECD:
Maximum temperature: 400ºC
Minimum detectivity: ≤0.1pg/mL (γ-666)
Linear range: 104
Emission source: 11mC63Ni
Flame photometric detector-FPD:
Maximum temperature: 400ºC
Minimum detectivity:
[P] ≤2×10-12g/s (tributyl phosphate)
[S] ≤2×10-10g/s (p-methylsulfurphosoharous)
Linear range: [P]:105 [S]: 103
Two air-hydrogen flames:For large volume injection or trace sample injection analyses;
Single air-hydrogen flame: sulfur sensitivity can be increased;
Direct output: for phosphorus or sulfur analyses;
Square-root output: for sulfur analyses;
Exposed-light protection:
When exposed-light current is more than 12μA, high voltage will be cut off automatically.
Nitrogen-phosphorus detector-TSD:
Maximum temperature: 400ºC
Minimum detectivity:
[N] ≤2×10-13g/s (azobenzene)
[P] ≤1×10-13g/s (malathion)
Linear range: [N]:105 [P]: 104
About Kolery Instrument
FQA
Q: What are the available delivery methods?
A: Our port location: Shanghai, Chongqing or other main ports of China
Delivery methods: by sea, by air, by truck, by express
Delivery range: worldwide
Q: How long is the probable delivery date?
A: Delivery time is differs with order quantity, technical parameters requirements, etc. For most of our oil testing equipment and other lab equipment, like halogen moisture tester, spectrophotometers, the delivery date is about 3-7 business days. Please contact with us for more details.
Q: What are the available payment methods?
A: Payment methods: By T/T, L/C, Western Union, Paypal, etc.
Payment terms: Generally, for small order T/T 100% advanced, we also accept T/T 40% advanced, the balance paid by T/T when the machine is ready. For big order, we can accept 100% irrevocable L/C at sight.
Q: How long is the warranty period?
A: We warrants most of machines supplied under agreed specification against defects in material and workmanship under normal use and service for a period of 1 years from the time customer receives the goods. For some items, we offer 2 years warranty. Please contact us for details about this.
Q: What's the mini order quantity?
A: MOQ: 1 unit/set
Packing and Shipping
Payment Term
MOQ | 1 Set |
Trade Terms | EXW, FOB, CIF, CFR |
Payment Terms | T/T, L/C |
Port of Loading | Any Port of China |
Packing Method | Internaional Standard Wooden Case |
Transportation Method | By Sea, By Land, By Air, By Express |
Supply Capability | 200 Sets/Month |
After Sales Service
* The warranty period is 24 months from commissioning acceptance date on. After the warranty period is over we provide lifelong maintenance and technical service.
* We guarantee the maintenance time no more than 3 working days and response time within 8 hour.
* We build instrument service profile for our clients to record the product service and maintenance conditions.
* After instruments start service, we will pay follow-ups to collect the service conditions.