China Thermal Impact High Low Temperature Shock Test Chamber, Find details about China Thermal Shock Test Chamber, Incubator from Thermal Impact High Low Temperature Shock Test Chamber
Model LTS-XX | 271916A | 100A | 216A | 500A | 1000A | 100B | 216B | 500B | 1000B | 100C | 216C | 500C | 1000C | |
Structure | precooling box, preheating box, test box; two-box or three box selectable | |||||||||||||
Valve device | Forced air valve device | |||||||||||||
Inside material | SUS304 stainless steel | |||||||||||||
Outside material | SUS304 stainless steel or cold rolled steel with power spraying. | |||||||||||||
Test plate | Stainless steel plate | |||||||||||||
Refrigerating system | Semi-hermetic double-stage compressor | |||||||||||||
Cooling way | Water-cooled/Air Cooled | |||||||||||||
Environmental temp. | 0ºC~+30ºC | |||||||||||||
Temp. shock range | -40ºC~+150ºC | -50ºC~+150ºC | -60ºC~+150ºC | |||||||||||
Temp. deviation | +2ºC | |||||||||||||
Temp.shock speed(3-box) | -40ºC~+150ºC/5min | -50ºC~+150ºC/5min | -60ºC~+150ºC/5min | |||||||||||
High temp.shock speed(2-box) | -40ºC~+150ºC/5min | -50ºC~+150ºC/5min | -60ºC~+150ºC/5min | |||||||||||
Preheating time(min) | 50 | 30 | 35 | 50 | 55 | 30 | 35 | 50 | 55 | 30 | 35 | 50 | 55 | |
Precooling time(min) | 60 | 40 | 40 | 60 | 70 | 40 | 40 | 60 | 70 | 40 | 40 | 65 | 80 | |
Temperature sensor | PT100 | |||||||||||||
Controller | Program-controlled liquid crystal touch screen | |||||||||||||
Setting range | -100ºC~200ºC/TI, E: OH OOM ~999H 59M/ CYCLE: 0 CYCLE~10000 CYCLE | |||||||||||||
Resolution ratio | Temperature: 0.01ºC/time:1min | |||||||||||||
Output method | PID+PWM+SSR control mode | |||||||||||||
Additional feature | Air outlet and inlet perception inspection control/ RS-232 remote monitoring management system | |||||||||||||
Safety device | 1.With no-fuse protection switch. | |||||||||||||
2.Control system with phase sequence protection and low voltage electrical protection. | ||||||||||||||
3. Over load protection device for refrigeration compressor | ||||||||||||||
4.Refrigeration compressor high and low voltage protection switch. | ||||||||||||||
5.With over-heat protection switch. | ||||||||||||||
6.Refrigeration compressor over oil pressure protection. | ||||||||||||||
7.Overload protection for circulation fan motor | ||||||||||||||
Customized service | Welcome to Non-standard,Specail requirements,OEM/ODM orders. | |||||||||||||
Details of model: power consume and equip with water chiller tower | ||||||||||||||
Model | Inside Dimension (W*D*H mm) | Power/kw | Water chiller (kw) | Water pipe diameter (the entry pressure of water) must not be less than 0.2Mpa | ||||||||||
271916A | 500*1550*500 | 380V, 3-phase, 55kw | 8 | 2 1/2 inches | ||||||||||
100A | 500*400*500 | 380V, 3-phase, 16kw | air cool | 2 inches | ||||||||||
100B | 500*400*500 | 380V, 3-phase, 19kw | air cool | 2 inches | ||||||||||
100C | 500*400*500 | 380V, 3-phase, 28kw | air cool | 2 1/2 inches | ||||||||||
216A | 600*600*600 | 380V, 3-phase, 28kw | air cool | 2 1/2 inches | ||||||||||
216B | 600*600*600 | 380V, 3-phase, 40kw | 5 | 2 1/2 inches | ||||||||||
216C | 600*600*600 | 380V, 3-phase, 47kw | 8 | 2 1/2 inches | ||||||||||
500A | 970*860*600 | 380V, 3-phase, 66kw | 8 | 2 1/2 inches | ||||||||||
500B | 970*860*600 | 380V, 3-phase, 92kw | 10 | 2 1/2 inches | ||||||||||
500C | 970*860*600 | 380V, 3-phase, 105kw | 10 | 2 1/2 inches | ||||||||||
1000A | 1000*1000*1000 | 380V, 3-phase, 75kw | 8 | 3 inches | ||||||||||
1000B | 1000*1000*1000 | 380V, 3-phase, 106kw | 10 | 3 inches | ||||||||||
1000C | 1000*1000*1000 | 380V, 3-phase, 120kw | 12 | 3 inches |
GJB 150.5A-2009 : test method of military equipment laboratory environment, temperature shock test | ||||||||||||
GJB150.5-86 temperature shock test. | ||||||||||||
GJB 360A-96 test method of electronic and electrical components 107 temperature shock test . | ||||||||||||
GB/T31485-2015 security requirement and test method of power battery designed for electromobile. | ||||||||||||
GB/T11158-2008 Technical conditions of high temperature test box. | ||||||||||||
GB/T10589-2008 Technical conditions of low temperature test box. | ||||||||||||
GB/T2423.1-2001 Test method of high temperature test box. | ||||||||||||
GB/T2423.2-2001 Test method of low temperature test box. | ||||||||||||
GB/T2423.22-2002 Temperature change test. |