Model | TOS-2020BCH TOS-2040BCH TOS-2050BCH | TOS-2020CF TOS-2040CF TOS-2050CF | TOS-2020CT TOS-2040CT TOS-2050CT | TOS-2020 TOS-2040 TOS-2050 | TOS-2020FG TOS-2040FG TOS-2050FG | TOS-2100C |
Max. bandwidth | 20/40/50MHz | 20/40/50MHz | 20/40/50MHz | 20/40/50MHz | 20/40/50MHz | 100MHz |
Attenuator switch | √ | √ | √ | √ | √ | |
Vertical encoder switch | ||||||
Vertical pulse switch | √ | |||||
Vertical sensitivity step | 10 | 10 | 10 | 10 | 10 | 11 |
High vertical sensitivity | 5mV/DIV | 5mV/DIV | 5mV/DIV | 5mV/DIV | 5mV/DIV | 2mV/DIV |
Low vertical sensitivity | 5V/DIV | 5V/DIV | 5V/DIV | 5V/DIV | 5V/DIV | 5V/DIV |
Sweep encoder switch | √ | √ | √ | √ | √ | |
Sweep pulse switch | √ | |||||
Sweep time base step | 20 | 20 | 20 | 20 | 20 | 22 |
Fastest sweep time | 0.2us | 0.2us | 0.2us | 0.2us | 0.2us | 50ns |
Slowest sweep time | 0.5s | 0.5s | 0.5s | 0.5s | 0.5s | 0.5s |
Dual sweep (Dual time base) | √ | |||||
Time base step auto-shift | √ | |||||
Trigger signal output | √ | |||||
CH1 signal output | √ | √ | ||||
Z-axis input | √ | √ | √ | |||
Trigger level lock | √ | √ | ||||
Frequency counter | √ | √ | ||||
Cursor readout | √ | |||||
Panel settings save & recall | √ | |||||
CRT illumination | √ | |||||
Delayed sweep | √ | |||||
Component test | √ |
Model | 20MHz | 40MHz | 50MHz | |||||
Vertical system | ||||||||
Sensitivity | 5mV~5V/DIV, 10 steps in 1-2-5 sequence | |||||||
Accuracy | ≤3% | |||||||
Vernier sensitivity | ≤1/2.5 of panel indicated value | |||||||
Bandwidth | DC (AC 10Hz)~20MHz | DC (AC 10Hz)~40MHz | DC (AC 10Hz)~50MHz | |||||
AC coupling | <10Hz (at 100kHz, 8DIV, frequency response -3dB) | |||||||
Rise time | Approx. 17.5ns | Approx. 8.75ns | Approx. 7ns | |||||
Input impedance | Approx. 1MΩ//Approx. 25pF | |||||||
DC balance shift | 5mV~5V/DIV: ±0.5DIV | |||||||
Vertical mode | CH1, CH2, DUAL (ALT/CHOP), ADD, CH2 INV | |||||||
Chopping repetition frequency | Approx. 250kHz | |||||||
Input coupling | AC, GND, DC | |||||||
Max. Input voltage | 400V peak-peak, AC frequency≤1kHz | |||||||
Common mode rejection ratio | >50:1 at 50kHz sine wave (set CH1 and CH2 at same sensitivity) | |||||||
CH2 INV BAL | Balanced point variation≤1DIV (referred to graticule center) | |||||||
Horizontal system | ||||||||
Sweep time | 0.2us~0.5s/DIV, 20 steps in 1-2-5 sequence | |||||||
Accuracy | ±3%, X10MAG: ±5% (20ns~50ns/DIV uncalibrated) | |||||||
Vernier sweep time control | ≤1/2.5 of panel indicated value | |||||||
Sweep magnification | X10 (fastest sweep time 20ns/DIV) | |||||||
Position shift@X10MAG | ≤2DIV at CRT screen center | |||||||
Linearity | ±5%, X10MAG: ±10% (0.2s~1us) | |||||||
Trigger system | ||||||||
Trigger mode | AUTO, NORM, TV-V, TV-H | |||||||
Trigger level lock | Not provided | |||||||
Trigger source | CH1, CH2, ALT, LINE, EXT | |||||||
Trigger coupling | AC: 20Hz to full bandwidth | |||||||
Trigger slope | "+" or "-" | |||||||
Sensitivity | Frequency | 20Hz~2MHz | 2MHz~20MHz | 20MHz~40MHz | 40MHz~50MHz | |||
CH1, CH2 | 1DIV | 1.5DIV | 2.5DIV | 3DIV | ||||
ALT | 2DIV | 3DIV | ||||||
EXT | 200mV | 800mV | ||||||
TV | Sync pulse>1DIV (EXT: 1V) | |||||||
External trigger input | ||||||||
Input impedance | Approx. 1MΩ//Approx. 25pF | |||||||
Max. input voltage | 400V (DC+AC peak), AC frequency≤1kHz | |||||||
X-Y mode | ||||||||
Sensitivity | 5mV~5V/DIV±3% | |||||||
X-axis bandwidth | DC~500kHz (-3dB) | |||||||
Phase error | ≤3° at DC~50kHz | |||||||
Calibration signal output | ||||||||
Waveform | Positive-going square wave | |||||||
Frequency | Approx. 1kHz | |||||||
Duty ratio | <48:52 | |||||||
Output voltage | 2Vpp±2% | |||||||
Output impedance | Approx. 1kΩ | |||||||
Frequency counter (only for TOS-2020CF, TOS-2040CF, TOS-2050CF) | ||||||||
Display | 6 digits LED | |||||||
Accuracy | ±0.01% | |||||||
Component test (only for TOS-2020CT, TOS-2040CT, TOS-2050CT) | ||||||||
Testing subject | Resistor, Capacitor, Coil, Diode, Zener or simple combination of the components | |||||||
Testing voltage | Approx. 9Vac pp | |||||||
Testing frequency | 50/60Hz | |||||||
Testing current | Approx. 0.6mA | |||||||
CRT | ||||||||
Type | 6-inch rectangular with internal graticule, 8x10DIV (1DIV=1cm) | |||||||
Phosphor | P31 | |||||||
Accelerating voltage | Approx. 2kV (20MHz); Approx. 12kV (40MHz) | |||||||
Trace rotation | Adjustable at front panel | |||||||
General | ||||||||
Power source | AC110V/220V±10%, 50/60Hz, Max. 35VA | |||||||
Accessories | Power cord x1, Operation manual x1, Probe x2 | |||||||
Dimension (WxHxD) | 310x150x455mm | |||||||
Weight | Approx. 8kg |