Gfuve Energy Meter Calibration Test Bench GF302D1

China Gfuve Energy Meter Calibration Test Bench GF302D1, Find details about China Portable Meter Test Equipment Class 0.1, Portable Meter Test Equipment for Electricity Me from Gfuve Energy Meter Calibration Test Bench GF302D1

Model NO.
GF302D1
Customized
Customized
Accuracy
0.05%, 0.1%
Power Supply
One Phase AC 100-265V, Frequency 50/60Hz.
Stability
0.01%/120s
Distortion
0.3% (Non-Capacitive Load)
Output Load
Each Phase 30va
Measuring Accuracy
0.05%Rg
Key Words
Portable Meter Test Equipment Class 0.1
Active Power Measuring Accuracy
0.05%Rg
Reactive Power Measuring Accuracy
0.1%Rg
Model
Portable Meter Test Equipment Dubai
Trademark
GFUVE
Transport Package
Standard Export Box
Specification
495mmx390mmx195mm
Origin
Beijing, China
Model NO.
GF302D1
Customized
Customized
Accuracy
0.05%, 0.1%
Power Supply
One Phase AC 100-265V, Frequency 50/60Hz.
Stability
0.01%/120s
Distortion
0.3% (Non-Capacitive Load)
Output Load
Each Phase 30va
Measuring Accuracy
0.05%Rg
Key Words
Portable Meter Test Equipment Class 0.1
Active Power Measuring Accuracy
0.05%Rg
Reactive Power Measuring Accuracy
0.1%Rg
Model
Portable Meter Test Equipment Dubai
Trademark
GFUVE
Transport Package
Standard Export Box
Specification
495mmx390mmx195mm
Origin
Beijing, China
GF302D1 portable meter test equipment class 0.1 dubai for electricity meters
Gfuve Energy Meter Calibration Test Bench GF302D1


GF302D1 portable meter test equipment class 0.1 dubai for electricity meters consists of an integrated three phase current and voltage source(up to 500V/120A or 500V/20A) and built-in three-phase electronic reference standard of accuracy class 0.05%. Characteristic features of the GF302D1 are its wide measuring range, high accuracy and high tolerance to unwanted external influences. The equipment offers high functionality combined with an excellent menu guided operation via built-in keyboards and colored 7" touch LCD-display.
Features
1. Accuracy class 0.05
2. 0-20A/0-500V, 0-120A/0-500V
3. Start testing and creep testing
4. Reference standard and power source integrated
5. Test by automatic or manual
6. 7 inch TFT touch screen
7. Weight light 15Kg
8. Recorder 500 sets energy meter data
9. Overload, short circuit, open circuit protection
Functions
1. Testing all kinds of energy meter in 1P2W, 1P3W, 3P3W, 3P4W
2. Measuring mechanical meter and electric meter
3. Power and energy measurements for active, reac\tive and apparent power
4. Measuring frequency, phase shift and power factor
5. Harmonic spectrum analysis for voltage and current up to the 51th order
6. Measuring the distortion factor
7. Vector diagram display and phase sequence indication on integrated colored screen
8. Energy dosing with built-in current source and voltage source
9. User friendly menu guided operation
10. Especially configured USB stick for storage of customer data
11. Easy verification and analysis of meter installations
12. Automatic operation without need of an external PC
Parameters
Electrical parameters
Accuracy class 0.05%, 0.1%
Power supplyOne Phase AC 100-265V, frequency 50/60Hz.
AC Voltage output
Range(U1,U2,U3)57.7V, 100V, 220V, 380V
or 69.3V, 120V, 240V, 480V( optional)
Adjustment range(0-120)%RG(1)
Adjust fineness0.01%RG, 0.1%RG, 1%RG, 10%RG as optional.
Stability0.01%/120s
Distortion0.3% (Non-capacitive load)
Output loadeach phase 30VA
Measuring accuracy0.05%RG
AC Current output
Range (I1, I2, I3 )200mA, 1A, 5A, 20A, 100A(optional)
Adjustment range(0-120)%RG
Adjustment fineness0.01%RG, 0.1%RG, 1%RG, 10%RG as optional.
Stability<0.01%/120s
Distortion≤0.3% (Non-capacitive load)
Output load30VA
Accuracy0.05%RG
Power output
Active power output stability<0.01%RG/120s
Reactive power output stability<0.02%RG/120s
Active power measuring accuracy0.05%RG
Reactive power measuring accuracy0.1%RG
Phase Output
Output adjustment range0°-359.999°
Output adjustment fineness10, 1, 0.1, 0.01 as optional.
Resolution0.01°
Accuracy0.03°
Power Factor
Adjustment range-1 ~ 0 ~ 1
Resolution10, 1, 0.1, 0.01 as optional.
Measurement accuracy0. 0005
Frequency Output
Adjustment range40Hz-70Hz
Output adjustment fineness5Hz, 1Hz, 0.1Hz, 0.01Hz as optional.
Resolution0.001Hz
Accuracy0.005Hz
Voltage /Current/Harmonic Setting
Harmonic number2-51times
Harmonic content0-40%
Harmonic phase0-359.99
Harmonic setting accuracy(10%±0.1%)RD(2)
Power Energy Measurement Error
Active power energy0.05%RG
Reactive power energy0.1%RG
Power Pulse Output
Power pulse typeactive pulse, reactive pulse
Active power pulse output5V,10mA
Power Pulse Input
Energy pulse typesupport active and reactive pulse, the highest frequency
power pulse input is 180K.
Mechanical parameters
Dimensions (W×D×H) (mm)495x390x195
Weight (kg)15
Environmental conditions
Ambient temperature-10°C to +50°C
Relative humidity35%-85%
(1) RG means range, the same as below;
(2) RD means the setted harmonic content, harmonic can be a single output, also multiple output.