Ventilation modes: | IPPV, A/C, PCV, SIMV, SPONT/CPAP, PSV |
Ventilator parameter ranges | |
Tidal volume(Vt) | 0 ~ 2000mL |
Frequency (Freq) Oxygen concentration | 1bpm ~ 100 bpm 21%-100% |
I/E | 4:1~1:8 |
PEEP | 0cmH2O ~ 40 cmH2O |
Pressure Limit | 20 cmH2O ~ 100 cmH2O |
Monitored Parameters | |
Frequency (Freq) | 0 /min ~ 100 /min |
Tidal volume(Vt) | 0 mL ~ 2500 mL |
MV Airway pressure Dynamic lung compliance testing ETCO2 Concentration | 0 L/min ~ 99 L/min 0 cmH2O ~ 100 cmH2O 1mL/cmH2O ~ 1000mL/cmH2O 0mmHg ~ 152mmHg (0%-20%) |
Oxygen concentration | 15 % ~ 100 % |
Oscillographs display: | |
P-T(pressure - time) | |
F-T(flow - time) | |
P-V loop (pressure - volume loop) | |
V-T(volume - time ) | |
ETCO2-T (End-tidal CO2 - time) | |
Alarms and protection | |
The AC power failure alarm | Power failure or no connection |
Internal battery backup low voltage alarm | ≤11.3±0.3V |
No tidal volume | No tidal volume within 6s |
High Minute Volume alarm Low Minute Volume alarm | 5L/min-99L/min 1L/min-30L/min |
High Airway pressure alarm Low Airway pressure alarm High oxygen concentration alarm Low oxygen concentration alarm | 20cmH2O-100cmH2O 0cmH2O-20cmH2O 19%-100% 18%-99% |
Continuous pressure alarm | (PEEP+1.5cmH2O) over 16s |
Suffocation warning Fan error Oxygen deficit | 5-60s Show on screen Show on screen |
The maximum limited pressure | <12.5 kPa |
Working conditions | |
Gas source | O2, AIR |
Pressure | 280kPa-600kPa |
Voltage | ~220V±22V |
Power frequency | 50Hz ± 1Hz |
Input power | 900VA (with air compressor) 250VA (without air compressor) |
Ventilation modes: | IPPV, A/C, PCV, SIMV, SPONT/CPAP, PSV |
Ventilator parameter ranges | |
Tidal volume(Vt) | 0 ~ 2000mL |
Frequence (Freq) Oxygen concentration | 1bpm ~ 100 bpm 21%-100% |
I/E | 4:1~1:8 |
PEEP | 0cmH2O ~ 40 cmH2O |
Pressure Limit | 20 cmH2O ~ 100 cmH2O |
Monitored Parameters | |
Frequence (Freq) | 0 /min ~ 100 /min |
Tidal volume(Vt) | 0 mL ~ 2500 mL |
MV Airway pressure Dynamic lung compliance testing ETCO2 Concentration | 0 L/min ~ 99 L/min 0 cmH2O ~ 100 cmH2O 1mL/cmH2O ~ 1000mL/cmH2O 0mmHg ~ 152mmHg (0%-20%) |
Oxygen concentration | 15 % ~ 100 % |
Graphical display: | |
P-T(pressure - time) | |
F-T(flow - time) | |
P-V loop (pressure - volume loop) | |
V-T(volume - time ) | |
ETCO2-T (End-tidal CO2 - time) | |
Alarm and protection | |
The AC power failure alarm | Power failure or no connection |
Internal battery backup low voltage alarm | ≤11.3±0.3V |
No tidal volume | No tidal volume within 6s |
High Minute Volume alarm Low Minute Volume alarm | 5L/min-99L/min 1L/min-30L/min |
High Airway pressure alarm Low Airway pressure alarm High oxygen concentration alarm Low oxygen concentration alarm | 20cmH2O-100cmH2O 0cmH2O-20cmH2O 19%-100% 18%-99% |
Continuous pressure alarm | (PEEP+1.5cmH2O) over 16s |
Suffocation warning Fan error Oxygen deficit | 5-60s Show on screen Show on screen |
The maximum limited pressure | <12.5 kPa |
Working conditions | |
Gas source | O2,AIR |
Pressure | 280kPa-600kPa |
Voltage | ~220V ±22V |
Power frequency | 50Hz ± 1Hz |
Input power | 900VA (with air compressor) 250VA (without air compreesor) |
FAQ
Q:Do you have any sole agent in the world ?
For DM6B Veterinary Anesthesia machine, we have sole agent in Mexico , other countries not yet now .
Q:If clients arrange engineers go to your company for training , is it for free ?
For cooperated clients, engineer's accommodation and meals are for free;
For potential customer, only meals for free, clients should pay for engineer's accommodation.
Q:How can we get the VISA / Invitation to visit your company ?
We will do the files for you in Nanjing city , and scan such files to you , go to the Chinese Embassy nearest of your city to get the VISA then .
Q:Do you have any clients in Africa?
Yes, we have . Our products have been sold to more than 200 countries, every client give us great feedback. With good quality and the best services, we have owned our customers' praise.
Q:How to be a agent of your company ?
Thank you so much . You can place a trial order of our products, and do the marketing research to see whether the products have good market demand, if yes, welcome to discuss the details with us .
Q:How many certificates do you have ?
ISO9001,ISO13485, Free Sale certificate, CE certificate
Q:How can I pay for the equipment?
You can pay Dollar,Euro,RMB by T/T,West Union or L/C to our bank as you want.
Q:How can I get the machine to my country?
1. By air ( if time is urgent)
2. By sea ( if time is enough)
3. By express ( If the port is far away from hospital)
We can suggest suitable shipping cost for you according our forwarder's suggestion and your detailed address.
Of cause,you can use your own forwarder in China.You just need to tell us the contact of your forwarder and we send the equipment to him/her.
Q:How to install the machines?
All the ICU products are easy to install with our installation video . Every model have the video ,we will send to clients before install it .
Q:Do you have engineer can come to our location for installation ?
Of course . Engineer can speak English very well and have passport so they can go everywhere at anytime .
Clients need to be in charge of their air tickets ,accommodation and meals if Q'ty is not too big .