500va Acw/ Dcw /IR Testing An9636hc Electrical Safety Testing Machine

China 500va Acw/Dcw/IR Testing An9636hc Electrical Safety Testing Machine, Find details about China Electrical Safety Test, Electrical Safety Analyzer from 500va Acw/Dcw/IR Testing An9636hc Electrical Safety Testing Machine

Model NO.
An9636hc
Trademark
Ainuo
Specification
426*132*470
Origin
Qingdao
Model NO.
An9636hc
Trademark
Ainuo
Specification
426*132*470
Origin
Qingdao
 
Product Description

The new-generation Ainuo comprehensive safety analyzer is mainly used for electrical safety testing of quality inspection institutions, laboratories and 3C and peripheral equipment. It has flexible channel configuration options and special design for power supply equipment, meeting requirements for multi-station quick test

Detailed Photos

500va Acw/Dcw/IR Testing An9636hc Electrical Safety Testing Machine


500va Acw/Dcw/IR Testing An9636hc Electrical Safety Testing Machine
Four in one function: AC withstand voltage, DC withstand voltage, insulation resistance, grounding resistance; Open short circuit test, arc detection, anti electric shock protection and other special functions.
Multi-channel: Optional 5-channel withstand voltage 3-channel ground bond board card, 6-channel withstand voltage 2-channel ground bond board card, 8-channel withstand voltage board card, 8-channel ground bond board card and other multi-channel cards.
Dual withstand voltage serial: Innovative design, dual-channel withstand voltage output setting, setting of voltage division ratio between input end, output end and ground of power unit, multi-point withstand voltage test at one time.
Fast: 0.5s accurate test, 0.1s fast switching; safety test accuracy of 1%, 9-level arc detection.
Automated management: intelligent program control such as barcode recognition, automatic matching of test programs, automatic start of testing, test data storage (U-disk), meeting modern management requirements of production line.
Product Parameters
 
FunctionTechnical indicator
AC withstand voltage testNominal output capacity 200VA (5000V/40mA), short circuit current is greater than 200mA; optional 500VA model.
Output voltage settingRange/AccuracyRange: 100~5000V, resolution: 1V, Accuracy: ±(1% × setting +5V)
Output frequency settingRange/Accuracy50Hz/60Hz, Accuracy: ±0.1Hz
Alarm current settingUpper limit/AccuracyRange: 0.00~100.00mA, resolution: 0.01mA, Accuracy: ±(1% × reading + 5 counts)
Lower limit/AccuracyRange: (0.000~9.999)mA, resolution: 0.001mA, Accuracy: ±(1% × reading + 5 counts)
Time settingRange of test timeRange: 0, (0.5~999.9)s, 0 is infinite, resolution: 0.1s, Accuracy: ±(0.1% × setting + 2 counts)
Ramp-up timeRange: 0, (0.1~999.9)s,0 is off, resolution: 0.1s, Accuracy: ±(0.1% × setting + 2 counts)
Ramp-down timeRange: 0, (0.1~999.9)s,0 is off, resolution: 0.1s, Accuracy: ±(0.1% × setting + 2 counts)
Initial voltage setting (0%-50%) × setting of output voltage
Current compensation setting0.000~10.00mA, total current + compensation current <100.00mA, automatic/manual
Arc detection1~9 (9 corresponds to most sensitive), 0 means that arc function is Off
DC withstand voltage testNominal output capacity 120VA( 6000VDC/20mA )
Output voltage settingRange/AccuracyRange: (100~6000) VDC, resolution: 1V, Accuracy: ±(1% × setting + 5V)
Alarm current settingUpper limit/AccuracyRange: 0.0~20000μA, resolution: 0.1μA/1uA, Accuracy: ±(1% × reading + 5 counts)
Lower limit/AccuracyRange: (0.0-999.9)μA, resolution: 0.1μA, Accuracy: ±(1% × reading + 5 counts)
Time settingRange of test timeRange: 0, (0.5~999.9)s, 0 is infinite, resolution: 0.1s, Accuracy: ±(0.1% × setting + 2 counts)
Ramp-up timeRange: 0, 0.4~999.9s, 0 is off, resolution: 0.1s, Accuracy: ±(0.1% × setting + 2 counts)
Ramp-down timeRange: 0, (1.0~999.9)s, 0 is off, resolution: 0.1s, Accuracy: ±(0.1% × setting + 2 counts)
Initial voltage setting (0%-50%) × setting of output voltage
Lower limit current for charging (0~350.0)uA, automatic/manual
Arc detection1-9 (9 is the most sensitive), 0 means arc function off
Insulation resistance testNominal output2500VDC/50GΩ
Output voltage settingRange/AccuracyRange: (100~2500) VDC, resolution: 1V, Accuracy: ±(1% × setting + 5V)
Alarm resistance settingRange of upper/lower limitRange: 0.10MΩ~50000MΩ, the upper limit includes the setting for no upper limit
Accuracy100~499V:0.10MΩ~999.99MΩ, ±(2% × reading + 2 counts)
1000~2000MΩ,±(5% × reading + 2 counts)
500~2500V: 0.10~999.99MΩ, ±(2% × reading + 2 counts)
1000~9999MΩ,±(5% × reading + 2 counts)
10000~50000MΩ,±(15% × reading + 2 counts)
Time settingRange of delay timeRange: 0, (0.5~999.9)s, 0 is infinite, resolution: 0.1s, Accuracy: ±(0.1% × setting + 2 counts)
Ramp-up timeRange: 0, (0.1~999.9)s, 0 is off, resolution: 0.1s, Accuracy: ±(0.1% × setting + 2 counts)
Ramp-down timeRange: 0, (1.0~999.9)s, 0 is off, resolution: 0.1s, Accuracy: ±(0.1% × setting + 2 counts)
Lower limit current for charging (0~3.500)μA, automatic/manual
Ground bond resistance testRated outputTest current up to 32A, open circuit voltage is lower than 12V;
Output current settingRange/AccuracyRange: (2.0A-32.0A) AC, resolution: 0.1A, Accuracy: ±(1% × setting + 2 counts)
Output voltage settingRange/AccuracyRange: 3.0~10.0 VAC, resolution: 0.1V, Accuracy: ±(1% × setting + 2 counts), open circuit
Output frequency settingRange/Accuracy50Hz/60Hz, Accuracy: ±0.1Hz
Alarm limit settingRange of resistance upper/lower limit3 A≤ output current ≤10A: 10~600 mΩ
11A≤ output current ≤25A: 10~300 mΩ
26A≤ output current ≤32A: 10~200 mΩ
Accuracy<100mΩ, ±(1% × reading + 1mΩ); ≥100mΩ, ±(1% × reading + 2 counts)
Compensation resistanceRange0~100mΩ, automatic measurement, compensation on/off
Test time settingRange/AccuracyRange: 0, (0.5-999.9)s, 0 is infinite, resolution: 0.1s, Accuracy: ±(0.1% × setting + 2 counts)
Dimension426*132*470(W×H×D,mm)