China ABC Overhead Cable (Aerial Bundled Conductor), Find details about China ABC Cable, Low Voltage Cable from ABC Overhead Cable (Aerial Bundled Conductor)
(1)Self-supporting | |||||||||||
Phase | Phase | Phase | Approx.Overall Diameter | Min.Bending Radius | Max. D.C. Resistance of Conductor at 20 | ||||||
AAC+UV-XLPE | Compact Conductor | UV-XLPE Insulation | |||||||||
No.X Normal Cross Section of Cores | No.of Al Wires | Overall Diameter | Thickness | Min. | Diameter | ||||||
No. X mm 2 | - | mm | mm | mm | mm | mm | kN | ohm/km | |||
4 X 16 | 7 | 4.8 | 1.2 | 0.98 | 7.2 | 17.42 | 2.07 | 1.91 | |||
4 X 25 | 7 | 6 | 1.4 | 1.16 | 8.8 | 21.3 | 3.3 | 1.2 | |||
4 X 35 | 7 | 7 | 1.6 | 1.34 | 10.2 | 24.68 | 4.5 | 0.868 | |||
4 X 50 | 7 | 8.3 | 1.6 | 1.34 | 11.5 | 27.83 | 6.2 | 0.641 | |||
4 X 70 | 19 | 10 | 1.8 | 1.52 | 13.6 | 32.91 | 8.9 | 0.443 | |||
4 X 95 | 19 | 11.6 | 1.8 | 1.52 | 15.2 | 36.78 | 12.3 | 0.32 | |||
4 X 120 | 19 | 13 | 1.8 | 1.52 | 16.6 | 40.17 | 15.6 | 0.253 | |||
4 X 150 | 19 | 14.6 | 1.8 | 1.52 | 18.2 | 44.04 | 19.2 | 0.206 | |||
3 X 16 | 7 | 4.8 | 1.2 | 0.98 | 7.2 | 15.55 | 2.07 | 1.91 | |||
3 X 25 | 7 | 6 | 1.4 | 1.16 | 8.8 | 19.01 | 3.3 | 1.2 | |||
3 X 35 | 7 | 7 | 1.6 | 1.34 | 10.2 | 22.03 | 4.5 | 0.868 | |||
3 X 50 | 7 | 8.3 | 1.6 | 1.34 | 11.5 | 24.84 | 6.2 | 0.641 | |||
3 X 70 | 19 | 10 | 1.8 | 1.52 | 13.6 | 29.38 | 8.9 | 0.443 | |||
3 X 95 | 19 | 11.6 | 1.8 | 1.52 | 15.2 | 32.83 | 12.3 | 0.32 | |||
3 X 120 | 19 | 13 | 1.8 | 1.52 | 16.6 | 35.86 | 15.6 | 0.253 | |||
3 X 150 | 19 | 14.6 | 1.8 | 1.52 | 18.2 | 39.31 | 19.2 | 0.206 | |||
2 X 16 | 7 | 4.8 | 1.2 | 0.98 | 7.2 | 14.4 | 2.07 | 1.91 | |||
2 X 25 | 7 | 6 | 1.4 | 1.16 | 8.8 | 17.6 | 3.3 | 1.2 | |||
2 X 35 | 7 | 7 | 1.6 | 1.34 | 10.2 | 20.4 | 4.5 | 0.868 | |||
2 X 50 | 7 | 8.3 | 1.6 | 1.34 | 11.5 | 23 | 6.2 | 0.641 | |||
2 X 70 | 19 | 10 | 1.8 | 1.52 | 13.6 | 27.2 | 8.9 | 0.443 | |||
2 X 95 | 19 | 11.6 | 1.8 | 1.52 | 15.2 | 30.4 | 12.3 | 0.32 | |||
2 X 120 | 19 | 13 | 1.8 | 1.52 | 16.6 | 33.2 | 15.6 | 0.253 | |||
2 X 150 | 19 | 14.6 | 1.8 | 1.52 | 18.2 | 36.4 | 19.2 | 0.206 | |||
1 X 16 | 7 | 4.8 | 1.2 | 0.98 | 7.2 | 7.2 | 2.07 | 1.91 | |||
1 X 25 | 7 | 6 | 1.4 | 1.16 | 8.8 | 8.8 | 3.3 | 1.2 | |||
1 X 35 | 7 | 7 | 1.6 | 1.34 | 10.2 | 10.2 | 4.5 | 0.868 | |||
1 X 50 | 7 | 8.3 | 1.6 | 1.34 | 11.5 | 11.5 | 6.2 | 0.641 | |||
1 X 70 | 19 | 10 | 1.8 | 1.52 | 13.6 | 13.6 | 8.9 | 0.443 | |||
1 X 95 | 19 | 11.6 | 1.8 | 1.52 | 15.2 | 15.2 | 12.3 | 0.32 | |||
1 X 120 | 19 | 13.01 | 1.8 | 1.52 | 16.6 | 16.6 | 15.6 | 0.253 | |||
1 X 150 | 19 | 14.6 | 1.8 | 1.52 | 18.2 | 18.2 | 19.2 | 0.206 | |||
(2) Phase + Supporting | |||||||||||
Phase | Supporting | Phase | Supporting | Approx. Overall Diameter | |||||||
AAC+UV-XLPE | AAAC+UV-XLPE | Compact Conductor | UV-XLPE Insulation | Conductor | UV-XLPE Insulation | ||||||
No.X Normal Cross Section of Cores | No.X Normal Cross Section of Cores | No.of Al Wires | Overall Diameter | Normal Thickness | No./Dia.of Al. Wire | Normal Thickness | |||||
No. X mm 2 | No. X mm 2 | - | mm | mm | No./mm | mm | mm | ||||
3 X 16 | 1 X 54.6 | 7 | 4.8 | 1.2 | 7/3.15 | 1.6 | 20.72 | ||||
3 X 25 | 1 X 54.6 | 7 | 6 | 1.4 | 7/3.15 | 1.6 | 23.63 | ||||
3 X 35 | 1 X 54.6 | 7 | 7 | 1.6 | 7/3.15 | 1.6 | 26.17 | ||||
3 X 50 | 1 X 54.6 | 7 | 8.3 | 1.6 | 7/3.15 | 1.6 | 28.53 | ||||
3 X 70 | 1 X 54.6 | 19 | 10 | 1.8 | 7/3.15 | 1.6 | 32.34 | ||||
3 X 95 | 1 X 54.6 | 19 | 11.6 | 1.8 | 7/3.15 | 1.6 | 35.24 | ||||
3 X 120 | 1 X 54.6 | 19 | 13 | 1.8 | 7/3.15 | 1.6 | 37.78 | ||||
3 X 150 | 1 X 54.6 | 19 | 14.6 | 1.8 | 7/3.15 | 1.6 | 40.69 | ||||
3 X 16 | 1 X 70 | 7 | 4.8 | 1.2 | 7/3.5 | 1.6 | 21.36 | ||||
3 X 25 | 1 X 70 | 7 | 6 | 1.4 | 7/3.5 | 1.6 | 24.26 | ||||
3 X 35 | 1 X 70 | 7 | 7 | 1.6 | 7/3.5 | 1.6 | 26.8 | ||||
3 X 50 | 1 X 70 | 7 | 8.3 | 1.6 | 7/3.5 | 1.6 | 29.16 | ||||
3 X 70 | 1 X 70 | 19 | 10 | 1.8 | 7/3.5 | 1.6 | 32.97 | ||||
3 X 95 | 1 X 70 | 19 | 11.6 | 1.8 | 7/3.5 | 1.6 | 35.88 | ||||
3 X 120 | 1 X 70 | 19 | 13 | 1.8 | 7/3.5 | 1.6 | 38.42 | ||||
3 X 150 | 1 X 70 | 19 | 14.6 | 1.8 | 7/3.5 | 1.6 | 41.32 | ||||
3) Phase+Supporting+ Service Connection | |||||||||||
Phase | Supporting | Service Connection | Phase | Supporting | Service Connection | Approx.Overall Diameter of Bundled Cable | |||||
AAC+UV-XLPE | AAAC+UV-XLPE | AAC+UV-XLPE | Compact Conductor | UV-XLPE | Conductor | UV-XLPE | Compact Conductor | UV-XLPE | |||
No.X Normal Cross Section of Cores | No.X Normal Cross Section of Cores | No.X Normal Cross Section of Cores | No.of Al.Wire | Overall Dia. | Normal | No./Dia.of Al. Wire | Normal | No. of Al. Wire | Overall Dia. | Normal | |
Thickness | Thickness | Thickness | |||||||||
No. X mm 2 | No. X mm 2 | No. X mm 2 | - | mm | mm | No./mm | mm | - | mm | mm | mm |
3 X 16 | 1 X 54.6 | 1 X 25 | 7 | 4.8 | 1.2 | 7/3.15 | 1.6 | 7 | 6 | 1.4 | 27.05 |
3 X 25 | 1 X 54.6 | 1 X 25 | 7 | 6 | 1.4 | 7/3.15 | 1.6 | 7 | 6 | 1.4 | 30.25 |
3 X 35 | 1 X 54.6 | 1 X 25 | 7 | 7 | 1.6 | 7/3.15 | 1.6 | 7 | 6 | 1.4 | 33.05 |
3 X 50 | 1 X 54.6 | 1 X 25 | 7 | 8.3 | 1.6 | 7/3.15 | 1.6 | 7 | 6 | 1.4 | 35.65 |
3 X 70 | 1 X 54.6 | 1 X 25 | 19 | 10 | 1.8 | 7/3.15 | 1.6 | 7 | 6 | 1.4 | 39.85 |
3 X 95 | 1 X 54.6 | 1 X 25 | 19 | 11.6 | 1.8 | 7/3.15 | 1.6 | 7 | 6 | 1.4 | 43.05 |
3 X 120 | 1 X 54.6 | 1 X 25 | 19 | 13 | 1.8 | 7/3.15 | 1.6 | 7 | 6 | 1.4 | 45.85 |
3 X 150 | 1 X 54.6 | 1 X 25 | 19 | 14.6 | 1.8 | 7/3.15 | 1.6 | 7 | 6 | 1.4 | 49.05 |
3 X 16 | 1 X 54.6 | 2 X 25 | 7 | 4.8 | 1.2 | 7/3.15 | 1.6 | 7 | 6 | 1.4 | 27.05 |
3 X 25 | 1 X 54.6 | 2 X 25 | 7 | 6 | 1.4 | 7/3.15 | 1.6 | 7 | 6 | 1.4 | 30.25 |
3 X 35 | 1 X 54.6 | 2 X 25 | 7 | 7 | 1.6 | 7/3.15 | 1.6 | 7 | 6 | 1.4 | 33.05 |
3 X 50 | 1 X 54.6 | 2 X 25 | 7 | 8.3 | 1.6 | 7/3.15 | 1.6 | 7 | 6 | 1.4 | 35.65 |
3 X 70 | 1 X 54.6 | 2 X 25 | 19 | 10 | 1.8 | 7/3.15 | 1.6 | 7 | 6 | 1.4 | 39.85 |
3 X 95 | 1 X 54.6 | 2 X 25 | 19 | 11.6 | 1.8 | 7/3.15 | 1.6 | 7 | 6 | 1.4 | 43.05 |
3 X 120 | 1 X 54.6 | 2 X 25 | 19 | 13 | 1.8 | 7/3.15 | 1.6 | 7 | 6 | 1.4 | 45.85 |
3 X 150 | 1 X 54.6 | 2 X 25 | 19 | 14.6 | 1.8 | 7/3.15 | 1.6 | 7 | 6 |