394kVA Diesel Generator Stamford Alternator 60Hz 400V Generator Set

China 394kVA Diesel Generator Stamford Alternator 60Hz 400V Generator Set, Find details about China Diesel Generator, Power Generator Set from 394kVA Diesel Generator Stamford Alternator 60Hz 400V Generator Set

Model NO.
CCW-394T6
Speed
Speed
Conditions of Use
Land Use
Trademark
GTL
Transport Package
PP Film
Specification
CE, ISO
Origin
China
HS Code
8408909220
Model NO.
CCW-394T6
Speed
Speed
Conditions of Use
Land Use
Trademark
GTL
Transport Package
PP Film
Specification
CE, ISO
Origin
China
HS Code
8408909220
394kVA Diesel Generator Stamford Alternator 60Hz 400V Generator Set
+ Assembled by Cummins diesel engine and Leroy Somer/Stanford alternator.
+ Three filters as standard, fuel and water separator as optional.
+ Radiator and fan with safety guard.
+ Single bearing alternator IP 23, Insulation Class H.
+ Heavyduty steel as base frame and 8hrs operation base fuel tank.
+ Automatic controlpanel and 3poles circuit breaker, internal cable
+ 12V battery, battery wires. + Battery charger and float battery charger as standard supply scope.
+ Optional soundproof canopy,ATS,synchronization panel,trailers.

 
Diesel Genset Features                                                                                                                   P.F=0.8  3Phase
Generating Set Performance 60Hz
Service P.R.PStandby
Rated outputkVA394 438 
Active power outputkW315 350 
Rated Speedr.p.m1800
Standard VoltageV380/220 
Voltage availableV480/277-460/265 - 440/254-416/240-240/139-220/127-208/120
Perforemance data refer to Standard Reference Conditions of ISO 8528:+25ºC,100m ALT,relative humidity 30% 
Power reduction acc.to DIN ISO 3046 Standard values:Above 100m ALT approx.1% per 100m.Above 25ºC(77ºF) approx.4% per 10ºC(50ºF). 
Prime Mover Performance                                                                             1800 r.p.m
SERVICE P.R.PStandby
Rated outputKW358399
Manufacturer Cummins
4 stroke Diesel Engine - Injection type Direct
Aspiration type Turbocharged&Aftercooled
Cylinders,number and arrangement 6 -L
Bore×Strokemm 140X152
Total DisplacementL14
Cooling system Water
Emission Certification N.A
Compression ratio 14:1
Specific fuel consumption(P.R.P)L/h87,1
Specific oil consumption(at full load)%<0.1
Total coolant capacityL60,6
Fuel SystemTypeDirect Injection Cummins PT(E)
           
1.P.R.P. Prime Power - ISO 8528:PRIME POWER is the maximum power available during a variable power sequence, which may be run for an unlimited number of hours per year, between stated maintenance intervals.The permissible average power output during a 24 hours period shall not exceed 80% of the prime power.10% overload available for governing purposes only.
2.Max Standby power  -ISO 3046 Fuel Stop power:Power available for use at variable loads for limited annual time (500h), within the following limits of maximum operating time: 100% load 25h per year ,90% load 200h per year. No overload available. Applicable in case of failure of the main in areas of reliable electrical network.
Synchronous Generator GTL
Model K300G4
Polesnum4
Winding Conections (standard) Star-serie
Insulation classH
Enclosure(according to IEC-34-5) IP23
Phases 3+N
Votage Regulators A.V.R (SX440)
Steady voltage precision within±1.0% from no load to full loading with cosΦ=0.8-1.0
Alternator used by GTL Gensets meet the requirements of following Standard:BS5000,VDE0530,NEMA MG1-32,IEC34,CA C22.2-100,AS1359
           
Generationg Set Installation Data                                                                      1800 r.p.m
EXHAUST SYSTEM
Exhaust Gas Temperature at full loadºC521
ºF969,8
Exhaust gas flowL/s1314
Maximum allowed back pressureKpa10
AIR REQUIREMENT
Air requirement for combustion at 100% load/rated speedL/s477
ft3/min(CFM)1010,1 
ELECTRIC STARTING SYSTEM 
Standard Battery Charging SystemA35
Minimum Recommended Battery Capacity-Cold Soak @ 0 °F (-18 °C)CCA900
Auxiliary voltageV24
LUBRICATION SYSTEM
Lube oil system including sump,filters,etc.L38,6
           
394kVA Diesel Generator Stamford Alternator 60Hz 400V Generator Set

394kVA Diesel Generator Stamford Alternator 60Hz 400V Generator Set
 
394kVA Diesel Generator Stamford Alternator 60Hz 400V Generator Set
Xiamen GTL Power System Co.,Ltd established in 2009,is a professional power generation solutions and supplier located in Xiamen of China,we engaged in the research,development, production,sales and service of Industrial diesel generator,Mobile diesel generator,Pump diesel generator,Gas generator,Air Compressor and Light towers.  

The Generators we provide can be both in Open skid,weather proof and Soundproof,power range from 5 kw to 4000 kw;
The Gas generator can range from 12 kw to 1500 kw;
The Air Compressor range from 55 CFM to 1600 CFM,maximum 34.5 bar;
The Light towers were designed to offer the widest choice,multiple solutions of lamps with metal halide floodlight and LED lamp to satisfy different application,additionally,it is totally customizable.

394kVA Diesel Generator Stamford Alternator 60Hz 400V Generator Set394kVA Diesel Generator Stamford Alternator 60Hz 400V Generator Set


394kVA Diesel Generator Stamford Alternator 60Hz 400V Generator Set394kVA Diesel Generator Stamford Alternator 60Hz 400V Generator Set