Contec Cms50d Oximetro De Pulso Pulse Oximeter

China Contec Cms50d Oximetro De Pulso Pulse Oximeter, Find details about China Oximeter, Pediatric Oximeter from Contec Cms50d Oximetro De Pulso Pulse Oximeter

Model NO.
CMS50D
Animal
Animal Examination
Language
Multiple Languages Choice
Product Name
Contec
Size
110 mm(L)*60 mm(W)* 24 mm(H)
Properties
Diagnosis & Injection
Trademark
CONTEC
Origin
China
Model NO.
CMS50D
Animal
Animal Examination
Language
Multiple Languages Choice
Product Name
Contec
Size
110 mm(L)*60 mm(W)* 24 mm(H)
Properties
Diagnosis & Injection
Trademark
CONTEC
Origin
China

CONTEC CMS50D Oximetro De Pulso Pulse Oximeter

Product Description

Introduction
CMS60D-VET Pulse Oximeter adopts Photoelectric Oxyhemoglobin Inspection Technology in accordance with Capacity Pulse Scanning & Recording Technology, which can be used to measure SpO2 and pulse through animal's tongue or ear. It is applicable for use in family and pet hospital, etc.

Features
1.Small in volume, light in weight and convenient to carry.
2.Easy and simple to operate, low in power consumption.
3.With function menu.
4.Display of SpO2 value.
5.Display of PR value and bar graph.
6.Display of pulse waveform.
7.Adjustable screen brightness, PR sound indication.
8.Review function.
9.Clock function.
10.Audible prompt for over-limit and low battery.
11.Battery status indication.
12.Low battery indication.
13.Storage function for SpO2 and PR values, and data stored can be uploaded to PC.
14.Real-time data can be uploaded to PC.
15.External SpO2 probe can be connected.

Performance
Display mode: color display
SpO2 measurement range: 0 % ~ 100 %(resolution: 1 %)
Accuracy: 70%~100%: ±2%
0%~69%: unspecified
PR measurement range: 30 bpm~250 bpm(resolution: 1 bpm)
Accuracy: ±2 bpm or ±2 %, whichever is greater.
Measurement performance in weak filling condition: SpO2 and pulse rate can be shown correctly when pulse-filling ratio is 0.4 %. SpO2 error is ±4 %, pulse rate error is ±2 bpm or ±2 %, whichever is greater.
Resistance to surrounding light: The deviation between the value measured in the condition of man-made light or indoor natural light and that of darkroom is less than ±1 %.
Power consumption: ≤ 100 mA
Voltage: DC 3.0 V
Power supply: two AA batteries
Continuous working time: 44 hours in theory
Safety class: internally powered equipment, type BF applied part

Physical characteristic
Dimension: 110 mm(L) × 60 mm(W) × 24 mm(H)
Weight: about 120 g(including battery)

Detailed Photos

Contec Cms50d Oximetro De Pulso Pulse Oximeter

 

Product List

-TELEMEDICINE products

-Pulse oximeter
-Patient Monitoring
-ECG machine(Electrocardiograph)/Holter ECG/Stress test ECG,
-EEG,
-Ultrasound Imaging,Pocket fetal doppler,fetal monitor,
-Blood pressure Monitor(ABPM),
-spirometer
-infusion/syringe Pump
-Digital Stethscope
-In-Vitro Diagnostics
-simulator
-Veterinary products


 

Company Profile


Contec Cms50d Oximetro De Pulso Pulse Oximeter

Contec Cms50d Oximetro De Pulso Pulse Oximeter



Contec Cms50d Oximetro De Pulso Pulse Oximeter
Contec Cms50d Oximetro De Pulso Pulse Oximeter