Air Cooled Heat Exchangers for Power Plant

China Air Cooled Heat Exchangers for Power Plant, Find details about China Air Cooled Heat Exchangers, Heat Exchanger from Air Cooled Heat Exchangers for Power Plant

Model NO.
sp-78
Design Serice
Be Viable
Tube Material
Copper
Fin Material
Aluminium
Pressure
3.0MPa
Structure Material
Metal Material
Heat Transfer Surface
Air Cooled Heat Exchangers
Trademark
Shenglin
Transport Package
Customerized Packing
Specification
Air Cooled Heat Exchangers
Origin
Shanghai, China
HS Code
841590900
Model NO.
sp-78
Design Serice
Be Viable
Tube Material
Copper
Fin Material
Aluminium
Pressure
3.0MPa
Structure Material
Metal Material
Heat Transfer Surface
Air Cooled Heat Exchangers
Trademark
Shenglin
Transport Package
Customerized Packing
Specification
Air Cooled Heat Exchangers
Origin
Shanghai, China
HS Code
841590900
Water to Air Copper Tube Air Cooled Heat Exchangers for Power Plant

Air Cooled Heat Exchangers SPECIFICATION:
1. Heat exchanger.
2. Can be customerized
3. Work Pressure: 0.2~3.1MPa
4. Fin space: 1.2~3.5mm
5. Tube Diameter: 7, 7.94, 9.52, 12.7, 16mm.


Air Cooled Heat Exchangers FEATURE:
1. Material: Copper, aluminum, galvanized plate
2. Aluminum foil: Hydrophilic or bare
3. Fin type: Louver fin or flat fin or corrugated fin
4. Copper pipe: Diameter 7mm or 8mm or 9.52mm, grooved or smooth tube
5. Pitch of fins can be adjusted between 1.8- 5.8mm.
6. Pitch of holes and pitch of rows: 25*21.65MM and 12.7*19.05MM
7. Suitable for R134A, R22, R404A, R407C refrigerant and so on
8. Voltage: 220V/1/50HZ and 380V/3/50HZ or other type.
9. Different alternative condensing fans available: Shaded pole or outer rotor fan motor.
10. Did gas examination under 3.0Mpa air pressure to ensure the tightness.
11. Widely used in refrigeration industry, cold room and other cooling system.
12. We can supply products as per customized samples or drawing.


Air Cooled Heat Exchangers tools:
Fin PatternCopper Tube O. D. (mm)Row Space(mm)Hole Space(mm)Fin Thickness(mm)
 
Fin Space(mm)
Flat finSine wave with blade finSmooth sine wave finWindow finSesamoid fin
A712.7210.105//1.31.3/
B713.217.60.105//1.31.3/
C712.720.40.105//1.3~1.81.3~1.8/
D7.9415.8825.40.1051.8~3.01.8~3.01.8~3.01.8~3.0/
E9.522225.40.105~0.151.6~3.21.6~3.21.6~3.21.6~3.2/
F9.522225.40.18~0.43.5~6.35////
G9.5221.65250.105~0.181.6~3.21.6~3.21.6~3.21.6~3.2/
H9.5221.65250.15~0.243.2~6.353.2~6.353.2~6.35//
I12.7527.531.750.115~0.151.5~3.51.5~3.51.5~3.51.5~3.51.6~3.2
J15.883338.10.115~0.151.5~4.01.5~4.01.5~4.0//
K15.8834.64400.115~0.15/2.6~3.52.6~3.5//

Air Cooled Heat Exchangers pictures:
Air Cooled Heat Exchangers for Power Plant
Air Cooled Heat Exchangers for Power Plant
Air Cooled Heat Exchangers for Power Plant