Hot Sale Medical Supply Lab Equipment Price of ESR Analyzer

China Hot Sale Medical Supply Lab Equipment Price of ESR Analyzer, Find details about China ESR, ESR Analyzer from Hot Sale Medical Supply Lab Equipment Price of ESR Analyzer

Model NO.
ESR-2068A
Max Test Speed
20 Samples/Hour
Suited ESR Tube
1.6ml Anticoagulant Blood
Accuracy Range of Sample
50mm~64mm
Interval of Reading
1 Minute
Display
128*240 LCD Screen
Dimension
310*190*180(Mm)
Weight
4.8kg
Trademark
Seeuco
Specification
CE
Origin
Jiangsu, China
HS Code
90278099
Model NO.
ESR-2068A
Max Test Speed
20 Samples/Hour
Suited ESR Tube
1.6ml Anticoagulant Blood
Accuracy Range of Sample
50mm~64mm
Interval of Reading
1 Minute
Display
128*240 LCD Screen
Dimension
310*190*180(Mm)
Weight
4.8kg
Trademark
Seeuco
Specification
CE
Origin
Jiangsu, China
HS Code
90278099
ESR-2068A Medical Supply Lab Equipment Price of ESR Analyzer


Pecification:
Number of test samples: 10 items at the same time
Max test speed: 20 samples/hour; Suited ESR tube: 1.6ml ESR tube(vacuum or normal);
Sample volume: 1.6ml anticoagulant blood(blood 1.28ml + anticoagulant0.32ml), the height of the inputting tube 60mm;
Accuracy range of sample: 50mm 64mm;
Read resolution: ± 0.2mm(westergren method result ± 1mm);
Interval of reading: 1 minute;
Testing time: The test time is 30 minutes, equivalents to 1 hour westergren method;
The test time is 60 minutes, equivalents to 2 hour westergren method;
Display: 128x240 LCD screen;
Power: 12V(SELV) by external power supply;
Dimension: 310 x 190 x 180 (mm);
Weight: 4.8kg;
Number of test samples10 items at the same time
Max test speed20 samples/hour
Suited ESR tube1.6ml ESR tube(vacuum or normal)
Accuracy range of sample50mm 64mm
Read resolution± 0.2mm(westergren method result ± 1mm)
Interval of reading1 minute

Technical Parameter: Measure range: 0— 140 mm/h(westergren method);
Testing pertinence: For westergren method result, the linear coefficient r≥ 0.98;
Testing repeatability: CV < 3%;
Testing accuracy of crate temperature: No more than ± 2.5° C between 15° C-30° C

Features: Method of inputting sample: Random sample position, testing at any moment;
Result Output: Printing No, westergren method result and full ESR curve, testing time and temperature;
If the testing time is 60 minutes, Kats value can be calculated, displayed, printed automatically;
The device has the function to choose environment temperature compensating.
If this function is valid, the test result under room temperature can be calibrated to 18° C by ESR calibrator.;
The device can save more than 150 result, including sample No., ESR value and dynamic curve;
The device has protection function when the power shuts down. The result will be saved automatically if the power shut down abruptly;
The device is equipped with thermal printer, can work on manual or auto mode;
Operation interface: Panel keyboard; Communication interface: RS-232 serial port