0-100-1500V Input DC Voltage Sensor / Voltage Transducer with Factory Price

China 0-100-1500V Input DC Voltage Sensor / Voltage Transducer with Factory Price, Find details about China Voltage Sensor, DC Voltage Sensor from 0-100-1500V Input DC Voltage Sensor / Voltage Transducer with Factory Price

Model NO.
ACTDS-DV
IP Rating
IP20
Certification
RoHS
Customized
Non-Customized
Input Voltage
DC 0-1500V
Output Signal
DC 4-20mA or 5V
Power Supply
12V,15V or 24V
Warranty
2 Years
ODM
Acceptable
Trademark
ACREL
Transport Package
Paper Carton
Specification
122x76x24mm
Origin
Jiangsu, China
HS Code
9030339000
Model NO.
ACTDS-DV
IP Rating
IP20
Certification
RoHS
Customized
Non-Customized
Input Voltage
DC 0-1500V
Output Signal
DC 4-20mA or 5V
Power Supply
12V,15V or 24V
Warranty
2 Years
ODM
Acceptable
Trademark
ACREL
Transport Package
Paper Carton
Specification
122x76x24mm
Origin
Jiangsu, China
HS Code
9030339000
Product Description

 
ACTDS/AHVS series DC voltage sensors are the measuring module that converts the measured DC voltage into the proportional DC current or DC voltage signal according to the optical isolation theory.The input side is highly insulated from the output side. They feature the high accuracy, linearity and integration, small size, simple structure, long-term stability and adaptability to various working conditions. They are widely used for system control and detection of electrical equipment in the power, petroleum, mine, chemical, railway, communication, building automation sectors. 


Functions and parameters

Main functions:
*
Bipolar and insulated measurement up to DC1500V
* Current output 4-20ma or voltage output 5V
* Power supply: DC12V, DC15V or DC24V
* Low consumption, low losses and low temperature drift
* High accuracy (offset, sensitivity, linearity) 0.5
* CE approval,in accordance with EN 50155: 2007,EN 50124-1: 2017 and EN 50121-3-2: 2015.

Datasheet :

 
Model
ACTDS-DV/I
ACTDS-DV/V
Input voltage
DC 100-1000V
Output signal
DC4-20ma or 0-20ma
DC0-5V or DC0-10V
Installation
Standard DIN rail
Power supply
DC12V,DC24V or DC15V
Accuracy
<200mS
Linearity
0.20%
Accuracy
0.5
Temperature drift
≤500PPM/ºC
Band width
DC
Consumption of current
<25mA+output current
Isolation withstand voltage
1kV;3kV/50Hz,1Min
Offset Voltage
≤10mV
Working temperature
-10~+70ºC
Ambient Conditions
-25~+85ºC
Dimensions and wirings

0-100-1500V Input DC Voltage Sensor / Voltage Transducer with Factory PriceCompany Profile

0-100-1500V Input DC Voltage Sensor / Voltage Transducer with Factory Price0-100-1500V Input DC Voltage Sensor / Voltage Transducer with Factory Price