China UL Standard Heat Resistant Cable Marker Tags, Find details about China Oil Resistant Cable Marker Tags, Replace Tyco Oil Resistant Cable Marker Tags from UL Standard Heat Resistant Cable Marker Tags
Order description | Width G(mm) | L Length(mm) | Printed Characters | Cable OD(mm) | |
Height G | Length l | ||||
MT-VLO-10.4-45/4- | 10.4 | 45 | 10.4 | 25 | 5.08~12.7 |
MT-VLO-10.4-53/4- | 10.4 | 53 | 10.4 | 33 | 5.08~12.7 |
MT-VLO-10.4-64/4- | 10.4 | 64 | 10.4 | 44 | 5.08~12.7 |
MT-VLO-10.4-76/6- | 10.4 | 76 | 10.4 | 56 | 5.08~12.7 |
MT-VLO-10.4-90/6- | 10.4 | 90 | 10.4 | 70 | 5.08~12.7 |
MT-VLO-15.0-45/4- | 15.0 | 45 | 15.0 | 25 | 12.7~19.1 |
MT-VLO-15.0-53/4- | 15.0 | 53 | 15.0 | 33 | 12.7~19.1 |
MT-VLO-15.0-64/4- | 15.0 | 64 | 15.0 | 44 | 12.7~19.1 |
MT-VLO-15.0-76/6- | 15.0 | 76 | 15.0 | 56 | 12.7~19.1 |
MT-VLO-15.0-90/6- | 15.0 | 90 | 15.0 | 70 | 12.7~19.1 |
MT-VLO-20.3-45/4- | 20.3 | 45 | 20.3 | 25 | 19.1~25.4 |
MT-VLO-20.3-53/4- | 20.3 | 53 | 20.3 | 33 | 19.1~25.4 |
MT-VLO-20.3-64/4- | 20.3 | 64 | 20.3 | 44 | 19.1~25.4 |
MT-VLO-20.3-76/6- | 20.3 | 76 | 20.3 | 56 | 19.1~25.4 |
MT-VLO-20.3-90/6- | 20.3 | 90 | 20.3 | 70 | 19.1~25.4 |
MT-VLO-25.4-45/4- | 25.4 | 45 | 25.4 | 25 | >25.4 |
MT-VLO-25.4-53/4- | 25.4 | 53 | 25.4 | 33 | >25.4 |
MT-VLO-25.4-64/4- | 25.4 | 64 | 25.4 | 44 | >25.4 |
MT-VLO-25.4-76/6- | 25.4 | 76 | 25.4 | 56 | >25.4 |
MT-VLO-25.4-90/6- | 25.4 | 90 | 25.4 | 70 | >25.4 |
Performance | Indicators | Test Method | ||
Typical properties | Unit | States | ||
Tensile Strength | Mpa | Unaged | ≥13.8 | ASTM G 154, MIL-DTL-23053E ISO 37, 500mm/min 175°C, 168h, ISO188 |
Heat aged/ After fluids/UV aged | ≥11.1 | |||
Elongation at break | % | Unaged | ≥200 | |
Heat aged/ After fluid | ≥100 | |||
Secant Modulus | Mpa | Unaged | <173 | ASTM D 882 |
Voltage Withstand | V | Unaged / After aged | 2500V, No breakdown in 60 sec. | IEC 243, ASTM G 154 175°C, 168h, ISO 188 |
Dielectric Strength | MV/m | Before aged | ≥19.7 | |
Heat aged/ After fluid/ UV aged | ≥15.8 | |||
Volume Resistivity | Ω.cm | Unaged | ≥1014 | IEC 93 |
Dielectric constant | - | Unaged | ≤3.2 | ASTM 150 |
Water Absorption | - | Unaged | ≤0.5 | ASTM 570, 23°C, 24h |
Bare Copper Corrosion | - | Unaged | No corrosion | 23°C, Rh 95±5%,24h 175°C,16h |
Heat Shock | - | Unaged | No cracks, flowing, dripping | Wind to the specified mandrel, 225°C, 4h |
Cold Flexibility | - | Unaged | No cracks | Wind to the specified mandrel, -30°C, 1h |
Flammability | - | Unaged | VW-1 | IEC 60332-1-3 Ed.1.0 b:2004 |
Smoke Density | - | Unaged | - | DIN 5510-2 |