Best Service Tester 60kv Vlf Hipot

China Best Service Tester 60kv Vlf Hipot, Find details about China AC Hipot Tester, Vlf High Voltage Tester from Best Service Tester 60kv Vlf Hipot

Model NO.
HMCOP-60kV
Output Frequency
0.1Hz, 0.05Hz, 0.02Hz
Stability of Frequency
Fluctuation < 0.5%
Measurement Accuracy
+-3%
Positive and Negative Voltage Peak Error
<=3%
Voltage Waveform Distortion
<=5%
Humidity
<=85%
Product Name
Vlf Hipot Tester
Test Voltage Range
30kv/40kv/50kv/60kv/70kv/80kv
Trademark
HMDQ
Transport Package
Wooden Box with Foam Inside
Origin
Hubei, China(Mainland)
HS Code
9022909090
Model NO.
HMCOP-60kV
Output Frequency
0.1Hz, 0.05Hz, 0.02Hz
Stability of Frequency
Fluctuation < 0.5%
Measurement Accuracy
+-3%
Positive and Negative Voltage Peak Error
<=3%
Voltage Waveform Distortion
<=5%
Humidity
<=85%
Product Name
Vlf Hipot Tester
Test Voltage Range
30kv/40kv/50kv/60kv/70kv/80kv
Trademark
HMDQ
Transport Package
Wooden Box with Foam Inside
Origin
Hubei, China(Mainland)
HS Code
9022909090
Best Service Tester 60Kv Vlf Hipot

VLF (Very Low Frequency) hipot Testers are suitable for testing power cables, transformers, switchgear, rotating machinery and other electrical apparatus.


VLF hipot teser Advantages:

1. Easiest to use Fully automatic microcontroller
2. Built-in printer
3. True sine wave output
4. Real-time display of actual output waveform
5. Ergonomic, menu guided, large backlit LCD
6. Storage of test results for later retrieval and print.
7. Over voltage and current protected
8. Variable frequency 0.1Hz, 0.05Hz, 0.02 Hz
9. Data of current, voltage and waveform directly sampled at HV side.
10. AC testing does not degrade good cable insulation
11. Harmful space charges are not injected into the cable insulation
12. No traveling waves are generated during testing
13. Rugged and reliable design less prone to failure from transients



VLF hipot tester detailed images :

Best Service Tester 60kv Vlf Hipot
VLF hipot tester Parameters:

1. Input: 220 ± 10% Volts AC, 50/60 Hz, single phase.
2. Output-Voltage:See below table 1.
3. Output frequency: 0.1Hz, 0.05Hz, 0.02Hz.
4. Stability of frequency: Fluctuation < 0.5%
5. Measurement accuracy: ±3%.
6. Positive and negative voltage peak errors: ≤3%.
7. Voltage waveform distortion: ≤5%
8. Construction: In two units: Controller and Booster..
9. Ambient conditions of use: temperature Indoor and
outdoor : -10ºC to + 50ºC.
10. Humidity:≤85%


Best Service Tester 60kv Vlf Hipot
 

Best Service Tester 60kv Vlf Hipot
Best Service Tester 60kv Vlf Hipot
Best Service Tester 60kv Vlf Hipot