High Accuracy Tangent Delta Tan Tester Transformer Dielectric Loss Test Machine

China High Accuracy Tangent Delta Tan Tester Transformer Dielectric Loss Test Machine, Find details about China Transformer Oil Tan Delta and Resistivity Tester, Transformer Oil Dielectric Loss Test System from High Accuracy Tangent Delta Tan Tester Transformer Dielectric Loss Test Machine

Model NO.
ZC-221A
Load Way
Electronic Load
Loading Method
Static Load
Display
Digital
Control
Manual Control
Weight
35kg
Power Source
220V
Oil Cylinder Position
None
Measuring Range
0.1%< Tg δ< 100%
Harmonic Adaptation
<3%
Trademark
KvTester
Transport Package
Wooden Box
Specification
460(L)*345(W)*350(H)
Origin
China
HS Code
9031809090
Model NO.
ZC-221A
Load Way
Electronic Load
Loading Method
Static Load
Display
Digital
Control
Manual Control
Weight
35kg
Power Source
220V
Oil Cylinder Position
None
Measuring Range
0.1%< Tg δ< 100%
Harmonic Adaptation
<3%
Trademark
KvTester
Transport Package
Wooden Box
Specification
460(L)*345(W)*350(H)
Origin
China
HS Code
9031809090

Description

High Accuracy Tangent Delta Tan Tester Transformer Dielectric Loss Test Machine
 
This device is a high accuracy tester to test tangent of dielectric loss and capacitance of various HV electrical equipments for generations and substations. It also applies to workshop, laboratory and R&D institutions.high

Features

1. LCD display, mass storage data, the instrument data can be exported through the U disk, and can generate a work report.

2. Many test modes: internal high voltage, external high voltage, internal standard, external standard, positive connection method, reverse connection method, self excitation method in a variety of ways to test; under the high pressure of outside the standard can do the high voltage of more than 10kV) dielectric loss test. 
3. CVT test one-step process: to test the full sealed CVT (capacitive voltage transformer) C1, C2 dielectric loss and capacitance, to achieve the C2, C1 testing at the same. The instrument can also test the CVT ratio and voltage angle difference. 
4. Multiple protections safe and reliable: with input voltage fluctuation, output short circuit, overvoltage, over current, temperature and other multiple protection measures. 
5. The instrument can be used for measuring the high-voltage electrical equipment of the non grounding or grounding, and can measure the capacitance of the capacitor voltage transformer tgδ and the main capacitor C1 and C2. 
6. The instrument is equipped with high voltage transformer, and takes safety protection measures against lightning, zero switching.

Product Parameters
High voltage output: 0.5~10KVEach files to increase 500V, a total of twenty files, capacity: 1500VA
Accuracytg δ: ±(reading*1.0%+0.04%)
Cx: ± (reading*1.0%+1PF)
Resolving powertg δ: 0.01%,Cx:1pF
Measuring range0.1%< tg δ< 100%
3PF<Cx<60000PF
10KV,Cx≤30000PF
5KV, Cx≤60000PF
Power supplyAC 220V±10% ,50±1Hz
Measurement methodPower frequency: 50Hz
Pilot frequency: 45Hz/55Hz Automatic frequency conversion
Harmonic adaptation≤ 3%
Service condition-15ºC-50ºC relative humidity<80%
Outline dimension460(L)*345(W)*350(H)
Weight35KG

High Accuracy Tangent Delta Tan Tester Transformer Dielectric Loss Test Machine
High Accuracy Tangent Delta Tan Tester Transformer Dielectric Loss Test Machine
High Accuracy Tangent Delta Tan Tester Transformer Dielectric Loss Test Machine
High Accuracy Tangent Delta Tan Tester Transformer Dielectric Loss Test Machine
High Accuracy Tangent Delta Tan Tester Transformer Dielectric Loss Test Machine
High Accuracy Tangent Delta Tan Tester Transformer Dielectric Loss Test Machine