IEC60720 Standard Cable PD Test Instrument Portable Partial Discharge Detector

China IEC60720 Standard Cable PD Test Instrument Portable Partial Discharge Detector, Find details about China partial discharge detector, partial discharge tester from IEC60720 Standard Cable PD Test Instrument Portable Partial Discharge Detector

Model NO.
GDPD-505
Control
Computer Control
Weight
0-100Kg
Power Source
AC220V
Oil Cylinder Position
Test and Measurement Instruments
Measurement channel
2-4PCS independent measurement channel
Sampling rate
Max. 100MHz of each channel
Power Supply
AC 220V±10%, 50Hz
Measurement range
1PC-10000PC
Sensitivity
1PC
Dynamic range
>80dB
Measurement frequency band
10kHz-30MHz
Digital filter
any setting within 50kHz-30MHz
Trademark
HVHIPOT
Transport Package
Wooden Case
Specification
SGS, ISO
Origin
Wuhan, China
HS Code
9030849000
Model NO.
GDPD-505
Control
Computer Control
Weight
0-100Kg
Power Source
AC220V
Oil Cylinder Position
Test and Measurement Instruments
Measurement channel
2-4PCS independent measurement channel
Sampling rate
Max. 100MHz of each channel
Power Supply
AC 220V±10%, 50Hz
Measurement range
1PC-10000PC
Sensitivity
1PC
Dynamic range
>80dB
Measurement frequency band
10kHz-30MHz
Digital filter
any setting within 50kHz-30MHz
Trademark
HVHIPOT
Transport Package
Wooden Case
Specification
SGS, ISO
Origin
Wuhan, China
HS Code
9030849000
IEC60720 Standard Cable PD Test Instrument Portable Partial Discharge Detector 
 
Product Description
 
GDPD-505 is a portable multi-functional PD online detector, which is suitable for partial discharge detection and location of high voltage electrical equipment such as Transformers, GIS, Switch Cabinet, Cable, Surge Arrester, Mutual Inductor and so on.
 
GDPD-505 equipped with different sensors will suitable for different tested objects.
 
The portable multi-functional PD inspection and testing instrument includes detecting host, PD detection software, high frequency current transformer (HFCT), acoustic electric integrated sensor, square-wave generator and connecting line, which is suitable for partial discharge detection and location of Cable.
 


Features

1. The main detector is portable design, robust and reliable.

2. Using 14inch laptop, built-in 20Ah Li-battery. Working up to 4hours without external power supply.

3. Strong anti-interference ability. Using digital filtering technology, effectively eliminate field interference. Multichannel data collection. Comprehensive analysis of electromagnetic wave and ultrasonic wave generated by partial discharge.

4. Easy wiring. BNC port for sensors and detector.

5. Strong software functions. With PD measurement and analysis, Measurement and analysis of PD repeat discharge times "n", anti-fixed interference, anti-dynamic interference, display mode of ellipse, straight line and sine wave can be selected.

6. The discharge result is accorded with IEC60720 standard. The display value unit is pc and mV.
 


Specifications
 
Measurement channel 2-4pcs independent measurement channel
Sampling rateMax. 100MHz of each channel
Sensitivity1pc
Measurement range1pc-10000pc
Dynamic range>80dB
Bandwidth 3dB of measurement frequency band10kHz-30MHz
Digital filterAny setting within 50kHz-30MHz
Power SupplyAC 220V±10%, 50Hz, power <50W
Environment temperature-20ºC-60ºC
Relative humidity≤ 95%
Altitude: ≤3000m

Sensor specifications
 
a. Acoustic electric integrated sensor

 
Measurement modeNon-contact
Signal transmission modeOptical fiber
Measurement signals: Ultrasonic signal, electric signal

b. HFCT sensor
 
Detecting frequency band50kHz~20MHz
Signal transmission mode50Ω Coaxial Cable
Sensitivity1pC


Packing list
 
Main unit 1pc
HFCT sensor 1pc
Acoustic electric integrated sensor1pc
Square-wave generator1pc
Coaxial cable 10M1pc
Twin-core optical fiber1pc
Ground cable1pc
User's guide1pc
Factory test report1pc

 
Detection Principle of High Voltage Cable

1. HF detection (Adopts high frequency current transformer)
a. Using coaxial cable to connect BNC interface of high frequency current transformer to BNC interface with electrical signal mark on the host.
(Note: Under this measuring method, no external power supply is needed, no need to turn on the power switch, and only need to open the notebook.)IEC60720 Standard Cable PD Test Instrument Portable Partial Discharge Detector

b. Calibration

The square-wave generator special line passes through the high frequency current transformer, and then the high frequency current transformer BNC interface is connected with the BNC interface of the host machine marked with an electric signal.

(For example, adjust the square wave generator to 100pC step, then display 100pC in the software interface, namely the signal calibration. Specific use method is mentioned in software instruction)
IEC60720 Standard Cable PD Test Instrument Portable Partial Discharge Detector

 

c. HFCT is an open type design, the current transformer is installed on the ground wire of the cable joint, fastening.

(Note: closed gently when fastening. Fasten mode of current transformer adopts magnetic adsorption, may occur at the openings of damage to the transformer due to impact)
IEC60720 Standard Cable PD Test Instrument Portable Partial Discharge Detector

2. Acoustic electric detection (Adopts acoustic electric integrated sensor) 

a. Using optical fiber to connect optical signal terminal of acoustic electric integrated sensor with optical signal terminal of the host, open the snap switch, switch step to optical signal terminal.

 (Note: when using optical signals, host needs to power on, press the rocker switch on the right crone of host panel, when the switch indicator light is on, indicates the battery switch is turned on, can start testing.)
IEC60720 Standard Cable PD Test Instrument Portable Partial Discharge Detector
b. Put the acoustic electric integrated sensor near the discharge point, using high voltage insulation rod and optical fiber to isolate high voltage, detection under the case of no connection to the cable, the specific detection principle is shown as below:
IEC60720 Standard Cable PD Test Instrument Portable Partial Discharge Detector

c. Turn off battery power switch in the right corner promptly, as soon as the test is completed.

IEC60720 Standard Cable PD Test Instrument Portable Partial Discharge Detector
IEC60720 Standard Cable PD Test Instrument Portable Partial Discharge Detector
IEC60720 Standard Cable PD Test Instrument Portable Partial Discharge Detector
IEC60720 Standard Cable PD Test Instrument Portable Partial Discharge Detector
IEC60720 Standard Cable PD Test Instrument Portable Partial Discharge Detector
IEC60720 Standard Cable PD Test Instrument Portable Partial Discharge Detector