Wide Range of Insulating Oil Filtration System

China Wide Range of Insulating Oil Filtration System, Find details about China Transformer Oil Purifier, Dielectric Fluid Purification from Wide Range of Insulating Oil Filtration System

Model NO.
ZYD-I-50
Color
Gray
Size
1800X1000X1900 mm
Weight
500 Kg
Function
Improve Dielectric Strength
Applicatiion
Both Oil Reclamation and Conditioning
Trademark
TOP Oil Purifier
Transport Package
Wooden Case
Specification
CE, SGS
Origin
Chongqing, China
HS Code
84212990
Model NO.
ZYD-I-50
Color
Gray
Size
1800X1000X1900 mm
Weight
500 Kg
Function
Improve Dielectric Strength
Applicatiion
Both Oil Reclamation and Conditioning
Trademark
TOP Oil Purifier
Transport Package
Wooden Case
Specification
CE, SGS
Origin
Chongqing, China
HS Code
84212990
Insulating Oil Reclamation Systems 
Insulating oil requires reclamation if oil neutralization values and related properties have deteriorated beyond acceptable levels due to the presence of excess acid, oxidation by products, or other age-related contaminants. Insulating oil reclamation systems incorporate an additional treatment stage to restore neutralization values, color, and other related oil properties. Our ZYD-I series of vacuum insulating oil purifiers can be used for both oil reclamation and conditioning and are also available in stationary and mobile configurations.

 

 

Attributes: 

 

Capacity ranges from: 1800 LPH to 30000 LPH 

Inlet Stainless Steel Filter is easy to clean and used to catch hold coarse dirt 

Standard efficiency of 0.5 / 1 Micron after fine filter 

Heat exchange through very low specific power electric heaters 

To improve the vacuum pumping speed, vacuum pump set in combination with rotary vane vacuum pump and roots pump are provided 

Easy to operate 

Compact equipment is also provided with pneumatic wheels for easy transport on road 

Duplex 3D stereo-evaporation technology, eliminating the liquid water very effectively 

Distinctive removing impurities technology filtering through double FH trapezoidal network and absorbing by high polymer without the mechanical power

UK G technology by which the trace water that is show chain, such as dissolved water, can be removed effect 

Carbon fiber infrared heating system that can make the oil contains zero sum of ethyne after treatment 

adopts the double-infrared liquid automatic controller, sensitive automatic pressure protector and the high effective equipment for degas, so it is easy to operate 

 

Optional Features: 

An exhaust condenser to measure the extracted water 

Condenser is equipped to settle the most volatile oil fractions which might distil back to the column 

Digital temperature measurement 

Digital precision vacuum gauge 

Digital flow meter 

Digital in line moisture content meter 

Ionic reaction columns to remove the acidity from the oil 

Audio / Visual fault annunciation System 

PLC control system 

Mobile Trailers can be provided 

Fully-enclosed and Semi-enclosed for weather-proof are available

Wide Range of Insulating Oil Filtration System
Wide Range of Insulating Oil Filtration System
Wide Range of Insulating Oil Filtration System
 

Technical Parameter:

ParameterUnitZYD-I-30ZYD-I-50ZYD-I-100ZYD-I-150ZYD-I-200ZYD-I-250ZYD-I-300
Flow rateL/h1800300060009000120001500018000
Working vacuumMPa-0.08~-0.099
Working pressureMPa≤0.3
Temperature rangeºC20 ~ 80
Power 3 ph 380V 50Hz (Or as needed)
Working noisedB(A)75757575808080
Heating powerkW303045607590120
Total powerkW35.537.552.571.486.5102.5135
Oil Inlet/Outlet  mmφ25φ32φ42φ50φ50φ60φ60
WeightKg60080010501400180020002200
OverallLengthmm1050110012001450160018001900
 Widthmm750800950950110012001200
 Heightmm1350140015001650180019001900
 
ItemUnitAfter treatment
Breakdown VoltagekV≥75
Moisture contentPPM≤3
Gas content%0.1
Impurity sizemicron≤1 (no free carbon)
IFTdynes/cm≥40
Acid valuemg KOH/g≤ 0.03
Dielectric loss factorstgδ(90ºC)≤0.001


Technical Parameter:

ParameterUnitZYD-I-30ZYD-I-50ZYD-I-100ZYD-I-150ZYD-I-200ZYD-I-250ZYD-I-300
Flow rateL/h1800300060009000120001500018000
Working vacuumMPa-0.08~-0.099
Working pressureMPa≤0.3
Temperature rangeºC20 ~ 80
Power 3 ph 380V 50Hz (Or as needed)
Working noisedB(A)75757575808080
Heating powerkW303045607590120
Total powerkW35.537.552.571.486.5102.5135
Oil Inlet/Outlet  mmφ25φ32φ42φ50φ50φ60φ60
WeightKg60080010501400180020002200
OverallLengthmm1050110012001450160018001900
 Widthmm750800950950110012001200
 Heightmm1350140015001650180019001900
 
ItemUnitAfter treatment
Breakdown VoltagekV≥75
Moisture contentPPM≤3
Gas content%0.1
Impurity sizemicron≤1 (no free carbon)
IFTdynes/cm≥40
Acid valuemg KOH/g≤ 0.03
Dielectric loss factorstgδ(90ºC)≤0.001 

Recommended Insulating Oil Testers
  1. Fully Automatic Insulating Oil Dielectric Strength Tester IIJ-II
  2. Fully Automatic Insulating Oil Dielectric Strength Tester DYT
  3. Fully Automatic Insulating Oil Dielectric Strength Tester DYT-2
  4. Three Cups Insulating Oil Dielectric Strength Tester IIJ-III
  5. Six Cups Insulating Oil Dielectric Strength Tester IJJ-VI
  6. Insulating Oil Dielectric Strength Tester IIJ-603
  7. Insulating Oil Tan Delta ( Dielectric Loss) Tester DLT0812
  8. Insulating Oil Dielectric Loss And Resistivity Tester TP-6100A
  9. Fully Automatic Water-Soluble Acid Value Tester PH-C
  10. Fully Automatic Surface/Interface Tension Tester IT-800
  11. Fully Automatic Oil Acidity Tester (6 cups) ACD-3000I
  12. Insulating Oil Gassing Property Tester DPT-20
  13. Insulating Oil Oxidation Stability Tester TP622
  14. Multifunctional Shaker SD-01
  15. Insulating Oil Water Content Tester TP-2100
  16. Online Insulating Oil Water Content Tester TPEE
  17. Transformer Oil Dissolved Gas Chromatograph GC-2010MD