Laboratory 512 Channel Battery Capacity Tester Machine

China Laboratory 512 Channel Battery Capacity Tester Machine, Find details about China Testing Equipment, Lithium Battery Tester from Laboratory 512 Channel Battery Capacity Tester Machine

Model NO.
TMAX-BT0502-512-C
Model NO.
TMAX-BT0502-512-C
Laboratory 512 Channel Battery Capacity Tester Machine
5V 2A 3A 5A 6A 512Channel Battery Analyzer for Lithium Battery Testing

Main performance of equipment
1. Each device can carry out constant current and constant voltage charging and constant current discharge test on 512 batteries meeting the voltage range.

2. Adopt the constant current constant voltage power supply of the invention patent, constant current to constant voltage switching without impact, especially suitable for the charging requirements of lithium-ion battery.

3. The AVR single-chip computer is used as the control center of the equipment, and the peripheral sampling circuit is used. The equipment can be controlled by the superior computer. When the computer is connected, the complete charge discharge curve of all channels can be saved, or it can be separated from the superior computer. Through the operation of the control panel, the constant current and voltage charging, constant current discharge test, time sorting and other work can be completed.
 
4. Each battery has an independent constant current and voltage source, and the self-made circuit does not affect each other.
 
5. Detect the voltage of each battery in real time. When charging, charge at constant current first. When the battery voltage reaches the set value, it will smoothly switch to constant voltage charging. When the set time or current termination conditions are met, the charging will end. During constant current discharge, when the battery voltage is lower than the set value, the discharge is ended and the corresponding battery indicator light is on.
 
6. It has the function of power-off protection, and can continue to operate after receiving the original workflow
 
7. The power tube is 50N06, which is suitable for batteries requiring low discharge voltage, such as lithium iron phosphate battery
 
8. The upper computer can set 32 working step parameters and 256 cycles, and each upper computer can be connected with 1-10 sets of single-chip system (less than 10 sets are recommended).
 
9. Supporting software functions
A) Graphic operation interface is used to display the data of voltage, current, time and capacity of each battery, and display the corresponding working status and abnormal conditions in various colors;
B) Battery capacity indication of any section (up to 100 sections);
C) Data points can be recorded according to the change conditions of voltage, current and time to form a complete charging and discharging curve data, and the time interval of curve data points is ≤ 4 Second;
D) Carry out battery sorting function under various conditions (capacity, time, open circuit voltage, discharge platform, etc.);
E) Automatically calculate constant current charging ratio, capacity loss, discharge efficiency, average voltage, median voltage and other data;
F) Set operator authority and operate in different levels;
G) Display charge discharge curve and cycle chart;


Specifications:
Number of device channels512 (Single CPU control)
Constant current range0.05 ~ 2A, 0.05-3A; 0.05-5A;0.05-6A
Resolution 1mA
Accuracy of current measurement±0.1%FS
 
Sampling current accuracy±0.1%FS
 
Voltage measurement range0 ~ 5V, resolution 1mV
Accuracy of voltage measurement±0.1%FS
 
Charging and discharging voltage rangeCharging: 0 ~ 4.5V, discharging: 4.5 ~ 2V
Constant voltage setting range3 ~4.5V
Accuracy of constant pressure setting±0.1%FS
 
Time range0-30000 min / step, accuracy: ± 0.1%
Heat dissipation modeCold wind
Battery ClampCylinder clamp, polymer clamp
Work loop sourceTemperature: 0 ~ 40 ºC,
relative temperature ≤ 85%
(no water condensation)
External size1600mm (W) × 550mm (L) × 1840mm (H)
Working power supplyThree phase four wire system,
AC380V ± 150%, 50Hz
Power consumption at full load≤11KW
 
Minimum configuration of computer system:
 
Dual core CPU or above,
4G or above memory,
500GB or above hard disk space,
EGA / VGA color display, one CD-ROM, one mouse
Windows XP or above operating system, one 6. RS232 serial communication port available.
7.The computer system shall be self configured by the user, and the number of the computer system shall be determined according to the actual needs.
General equipment configuration and standardsAppearance color of equipment,
Case: silver white,
Cabinet: silver white.
Attach the Chinese operation manual and software U disk.


Laboratory 512 Channel Battery Capacity Tester Machine
Laboratory 512 Channel Battery Capacity Tester Machine
Laboratory 512 Channel Battery Capacity Tester Machine
Laboratory 512 Channel Battery Capacity Tester Machine

Laboratory 512 Channel Battery Capacity Tester Machine
Laboratory 512 Channel Battery Capacity Tester Machine
Laboratory 512 Channel Battery Capacity Tester Machine
Laboratory 512 Channel Battery Capacity Tester Machine
Laboratory 512 Channel Battery Capacity Tester Machine

1.  We supply machines with battery technology support.
2.  We supply full set of lithium battery equipment for lab research, pilot scale research and production line.

Laboratory 512 Channel Battery Capacity Tester Machine

1 Standard exported package: Internal anticollision protection, external export wooden box packaging.
2 Shipping by express, by air, by sea according to customers' requirements to find the most suitable way.
3 Responsible for the damage during the shipping process, will change the damage part for you for free.