2-Channel 4-20mA to Modbus Rut Converter

China 2-Channel 4-20mA to Modbus Rut Converter, Find details about China 0-20mA to Modbus Converter, 0-20mA to RS232 Converter from 2-Channel 4-20mA to Modbus Rut Converter

Model NO.
ISO 4021
Size
83X51X37mm
Warranty
2 Year
Certification
Ce, RoHS, SGS
Process Temperature
-20~80 Cel. Deg.
Trademark
SUNYUANSZ
Transport Package
35mm DIN Rail-Mounted
Specification
CE RoHS, SGS
Origin
Shenzhen, China
Model NO.
ISO 4021
Size
83X51X37mm
Warranty
2 Year
Certification
Ce, RoHS, SGS
Process Temperature
-20~80 Cel. Deg.
Trademark
SUNYUANSZ
Transport Package
35mm DIN Rail-Mounted
Specification
CE RoHS, SGS
Origin
Shenzhen, China
2-Channel 4-20mA to Modbus Rut Converter

0-75mV|0-20mA to RS232|RS485 Modbus RTU Converter Features:
-Analog signal acquisition, isolated conversion RS485/232 output
-Testing accuracy>0.05%
-Can be remotely reconfigured for modules accuracy
-Input signal/Output signal: 3000VDC
-Wide power supply range: 8~50V
-High reliability, easy programme, installation.
-Can programme setting module address, baud rate, Modbus RTU

0-75mV|0-20mA to RS232|RS485 Modbus RTU Converter Applications:
-Signal testing/ monitoring /control
-RS232/485 industrial automation control system
-Industial field signal isolation
-Process Monitoring & Control
-Test sensors signal
-Laboratory Data Acquisition
-Medical machine monitoring
-4~20mA/0~20mA signal acquisition

0-75mV|0-20mA to RS232|RS485 Modbus RTU Converter Introduction:
ISO4021 series realizes sensor to host signal acquisition for testing analog signal or remote applications. Software configurable for a wide variety of sensor types, including: Analog input, analog output, and digital I/O, ISO4021 series are widely used in RS232/485 automation control system, 4~20mA/0~5V signal testing, small signal testing, Monitoring &Control, remote data acquisition applications.
Including power supply isolation, signal isolation, linearization, A/d conversion and RS232C/RS485 serial communication. For up to 256 channels per serial port, ISO4021 Series modules, adopts ASCII format and MODBUS, its injunction fully encapsulated to ADAM modules, baud rate can be intercalated by code, can be used in the same RS485 lines with other manufacturers modules, convenient for computer programme.
ISO4021 series modules is SCM based intelligent monitoring and control system, with all calibration, High and Low alarm, address, input ranges, baud rate, data format and linearizing parameters stored in EEPROM non volatile memory.
ISO4021 series modules are designed as industrial standard, input signal/out signal isolation, 3000VDC isolated. Temperature range is minus 45 to + 85 centigrade


ISO 4021 Sereis A-D Converter Functions:
ISO 4021 isolated modules to test one channel voltage/current signals, or 2 channel common ground and isolation current/voltage signals.

Anaolg Input Module:
24 bit accuracy, have been calibrated all signal input before ex factor. Also, Users can programme himself, Two input types must be same when testing two signals.

Communication software:
Communication Interface: 1 standard RS485 interface or 2 standard RS232 interface
Communication agreement: Standard ASCII, MODBUS, can make network communicate

With PLC, RTU or watch software.
Data format: 10 bit, 1 start bit, 8 data bits, 1 stop bit.
Communication address (0~255) and baud rate (300\600\1200\2400\4800\9600\19200\
38400BPS), Max. Communication distance: 1200m, connect by both twists shiled cable. ± 15KV ESDprotection, communication response time is less than 100mS.

Anti jamming:
Set checksum according to need. Its inside contains MOMENTARY bate diode, can
Restrain surge impulse, protect modules.

4-20mA|0-5V|0-75mV|0-20mA to RS232|RS485 Modbus RTU Converter Model selection:

ISO 4021A U(A) -232/485

Input voltage or current signal
U1: 0-5V A1: 0-1mA
U2: 0-10V A2: 0-10mA
U3: 0-75mV A3: 0-20mA
U4: 0-2.5V A4: 4-20mA
U5: 0-± 5V A5: 0-± 1mA
U6: 0-± 10V A6: 0-± 10mA
U7: 0-± 100mV A7: 0-± 20mA
U8: Customized A8: Customized

Communication interface
485: Output is RS-485 interface
232: Output is RS-232 interface
232/485: Output is RS-232orRS-485interface, RS232/485 switchover freely

 
InputPower supplyOutput
DC Current or voltage signal8--50VDCRS232 OR RS485

2-Channel 4-20mA to Modbus Rut Converter
2-Channel 4-20mA to Modbus Rut Converter
2-Channel 4-20mA to Modbus Rut Converter
2-Channel 4-20mA to Modbus Rut Converter
2-Channel 4-20mA to Modbus Rut Converter
2-Channel 4-20mA to Modbus Rut Converter